DG-180
Digital Keypad Operation Manual
Features:
1. Adjustable length of Master Code from 4 to 6 digits.
2. Allow up to 1000+10 PINs
3. Split-off controller and keypad for high security.
4. Lockout function enables the controller to lockout for 60 seconds upon entering
invalid PINs for 5 times. (The keypad without beep sound during the period).
5. Controller with keypad sound to avoid incorrect key-in.
6. Additional input for anti-tailgating function to ensure high security access control.
7. Built-in tamper switch.
8. Non-volatile memory allows to retain all setting codes in the event of total power
failure.
9. Dual relays to control door lock and other security devices.
10. Aluminum alloy casing with vandal resistant screws for enhanced safety and
durability.
11. Epoxy sealed for waterproof
12. Extremely slim body and narrow faceplate suitable for all types of door frames
44
150
6.7
63
72.50
6
Operating Voltage 12~24 VAC/VDC
Current Draw
Pull in: 50mA/12VDC
;
Holding: 20mA/12VDC
Keypad
6X2 matrix keypad (0~9,
,
#
)
Input
2 contacts for Request-To-Exit
1 contact for Door Reed Switch
Output 2 relays (N.O. / N.C. / Com.)
LED status Indication
2 LED indicators display
(
Blue/Green/Yellow/Red
)
Memory Volume 1000+10 PINs
Relay Rating
Relay Strike Time
N.O 10A/120V~10A/120VAC, N.C 7A/250V~10A/28VDC
01~99 seconds
Ambient Humidity 5%~95% (Non-condensing)
Operating Temperature -20°C~70°C
Mode
Signal
Status
Blue Stay On Power on, Standby
Green Stay On First relay active
Standby
Red Stay On
Second relay active
Yellow Stay On
Enter programming mode
Green Stay On
Red Stay On
The slot position of first relay is available.
The slot position of first relay is unavailable.
LED
Programming
Green Stay On
Red Stay On
The slot position of second relay is available.
The slot position of second relay is unavailable.
1 Beep
Press any key , enter programming mode
Standby
2 Beeps
Incorrect PIN
1 Beep
Correct Input data, Exit programming mode
Beep
Programming
3 Beeps
Incorrect Input data, other incorrect operation, duplicated PIN
Specification
Status Indication & Default Setting Parameters
Beep & LED Indication:
Pull in: 80mA/24VDC
;
Holding: 20mA/24VDC
Unit:mm