background image

Supported Standards

VXI-11 Capabilities

Fully VXI-11.3 compliant 

   VXI-11.3  

Device Interface

   Sockets  

15 + 1 for UDP

   Channel types  Data, Abort and Interrupt

   Links   

64

   Interface Names  inst0 for general use

 

 

inst1 for transparent data

VXI-11.3 Functions

All  VXI-11.3  functions  including  device  read, 

write, local, remote, clear, trigger, readstb, lock 

and unlock.

RPC Protocol

Conforms to ONC RPC Version 2, VXI-11

Ethernet Interface

   Type   

IEEE 802.3 compliant

   Speeds  

10BaseT (10 Mb/s)

 

 

100BaseT (100 Mb/s)

   IP Address 

Static or DHCP

   Factory setting  192.168.0.254 static

   Interface name  any [inst0], [inst1]

WebServer Capabilities

Provides the following HTML 4.01 compatible 

web pages:

 Welcome

 Configuration

 Confirmation

 Reboot

IEEE 488.2 Capabilities:

Runs all required 488.2 Common Commands,  

incorporates  an  extended  IEEE-488.2  Status 

Reporting Structure and the Message Exchange 

Protocol.

SCPI Capabilities:

Incorporates the SCPI Command Tree shown in 

Figure 2.  Complies with SCPI version 1994.0

8013: SPECIFICATIONS

Signal Characteristics

The 8013's parallel I/O signals have the follow-

ing  electrical  characteristics.  All  time  delays 

listed here are maximums, all pulse widths are 

minimums.

Inputs

  128 Digital I/O ,

 

2 Status  and Reset Inputs

Input

  High = > +2.0 V  @ ±10 µA

Logic 

Low = <0.8 V @ 250 µA

 

Levels

   with 33 Kohm pullup to +5 Vdc for  

 

sensing contacts.

 

Max High = 5.5 V

Input 

  External Data Inhibit line

Timing

  SETS within 1 µs of the active edge  

 

of the EDR Input signal and resets 

 

after data is loaded. Data loading

 

time for 6 BCD/HEX characters is  

 

0.15 ms (typ.) after the 8013 has been  

 

addressed as a Talker 

Output 

High = >3 V with  3 mA source

Logic 

High =>2 V with  24 mA source

Levels 

Low = 0.0 to +0.55 Vdc, 48 mA sink 

Output

  Data is transferred to the 

Timing

  output 2 to 3 ms after receipt of a  

 

message depending upon data trans- 

 

fer mode and command.

 

Pulse width  10 to 30000 ms

Data Stb

 Output pulse width, 5 µs.

Trigger

  Output pulse width, 5 µs

Remote

  Output level  asserted when in the  

 

remote state

Reset 

  Output pulse width, 70 µs when 

 

8013 reset.

Table 2   Digital IO Functions

 

 

Input  Bytes

 

Input Signal polarity

 

Input Handshaking

 

Talk data format

 

Talk data conversion table

 

Output Bytes

 

Output Polarity

 

Output Handshaking

 

Listen data format

 

Control line polarities

 

SENSe input polarities

 

STATus register configurations

 

SOURce output polarities

Controls and Indicators

CONTROLS

LAN Rst Board edge push-button

LEDs

PWR 

Indicates power on

LAN 

Unit good and connected to an active  

 

network

ACT 

Transferring messages to/from  

 

the network

RDY 

Unit has passed self test

TALK  Unit is addressed to talk

LSTN    Unit is addressed to listen

SRQ 

SRQ asserted on GPIB bus

ERR 

Blink for a detected soft error or 

 

solid On for a command error

Physical

Size, L x W x H 

  7.0 x 5.5 x 0.55 inches   (178  x 140 x 14 mm)

Material

   PCB     

FR406 Fiberglass

   Components  

RoHS compatible

   Construction 

Lead Free

Connector and Headers

   Digital I/O: 

150-pin, 3 row male conn

   Ethernet: 

RJ-45   

 

Temperature

   Operation 

-10° C to +70° C

   Storage  

-20° C to +85° C

Humidity

   0-90% RH without condensation

Power 

      

+5 Vdc @ 500 mA (typ)

Included Accessories

Instruction Manual

Support CD with sample programs

LAN Crossover Cable

Available Accessories

See Ordering Guide on page 5 for a complete list 

of accessory items.

  Mating short connector, P/N 902308

  Mating tall connector, P/N 902331

  Wiring Kit w/1 ft cable, P/N 115606

  Wiring Kit w/2 ft cable, P/N 115607

  Shielded Bulkhead Adapter, P/N 902329

  4813 Relay Driver Board, P/N 115490

  4813 DC-37 Relay Driver Board, P/N 115790

Data subject to change without notice.  Copyright 2010 ICS Electronics

03/10

Содержание 8013

Страница 1: ...n connector at one end of the card An RJ 45 header on the other end of the 8013 contains the Ethernet signals Applications include controlling switching matrices displays or large signal arrays Versatile Digital Interface The 8013 s digital interface is configured with commands over the network The configuration commands permit the user to designate the 128 data lines as inputs and or outputs in 8 b...

Страница 2: ...s with a com mand or transferred transparently The 8013 converts the data string characters into packed HEX bytes latches the data in the configuredoutputbytesandgeneratesadatastrobepulsetoupdate the external device The data strings can be a series of decimal values ACSII HEX characters or the 30 3F HEX characters used in ICS s earlier interfaces Reading The Input Signals The 8013 has three ways to...

Страница 3: ...racters in the user s Talk conversion table The SENSe branch gives the user a way to read digital data from a single byte or from the configured input bytes When reading data from a specific byte input data polarity can be assigned on a bit by bit basis The SOURce branch provides a way to write values to a byte or to the configured output bytes When data is outputted to a specific byte output data pol...

Страница 4: ...at can be used by virtually any operating system to control the 8013 While a VXI 11 3 interface like the 8013 will oper ate in an LXl system LXI devices are limited to Windows operating systems with VISA libraries and require IVI drivers Easy Network Setup There are three ways to set the 8013 s network settings The 8013 includes an internal WebServer that with HTML web pages that can be accessed b...

Страница 5: ...h boards are disabled at power turn on time and are only enabled when the output signals have been configured and are stable The 4813 Relay Driver Board has 128 sink type relay drivers that switch up to 48 volts and sink up to 500 mA of current Four 36 pin headers have 32 relay drivers outputs 4 bytes on each header One byte or 8 bits on each header can be converted to a standard 8013 I O signals a...

Страница 6: ...te with 115656 L cable and or 902334 female connector PCB male header is P N 902332 ORDERING INFORMATION Part Number Ethernet to Parallel Digital Digital Interface Board Includes Instruction Manual and Configuration Disk 8013 Ethernet to Parallel Digital Digital Interface Board Board only 115602 Mating digital I O 150 pin female connector short solder pins 902308 Mating digital I O 150 pin female c...

Страница 7: ...48 mA sink Output Data is transferred to the Timing output 2 to 3 ms after receipt of a message depending upon data trans fer mode and command Pulse width 10 to 30000 ms Data Stb Output pulse width 5 µs Trigger Output pulse width 5 µs Remote Output level asserted when in the remote state Reset Output pulse width 70 µs when 8013 reset Table 2 Digital IO Functions Input Bytes Input Signal polarity I...

Отзывы: