Before You Begin 

Before you can install the USB

-2000

, you need to prepare your site.  

1.  Determine where the host computer is to be located and set up the 

computer. 

2.  Determine where you want to locate the USB device(s). 

3.  If you are using surface cabling, ensure you have enough fiber-optic 

cabling to connect the two locations. 

OR 

    

If you are using premise cabling, ensure fiber-optic cabling is 
installed between the two locations, with fiber-optic information 
outlets located near both the computer and the USB device. 

Installing the LEX unit 

1.  Place the LEX unit near the host computer. 

2.  Plug the power adapter into a suitable AC outlet. 

3.  Connect the power adapter to the LEX unit. 

4.  Plug the Type B connector on the USB cable (included) into the 

Host port on the LEX unit. 

5.  Plug the Type A connector on the USB cable into a USB port on the 

host computer. 

 NOTE

:

 The host computer must be equipped with an EHCI (USB 2.0) host 

controller. Support for OHCI/UHCI (USB 1.1) host controllers is 
not provided. 

Installing the REX unit 

1.  Place the REX unit near the USB device(s). 

2.  Plug the power adapter into a suitable AC outlet. 

3.  Connect the power adapter to the REX unit. 

Connecting the LEX unit to the REX unit 

With Surface Cabling 

1.   Plug one end of the fiber-optic cabling (not included) into the Link 

port on the LEX unit. 

2.   Plug the other end of the fiber-optic cabling into the Link port on the 

REX unit. 

  

Содержание USB-2000

Страница 1: ...which case the user will be required to correct the interference at his own expense CE Statement We Icron Technologies Corporation declare under our sole responsibility that the USB 2000 to which thi...

Страница 2: ...the LEX unit 5 Installing the REX unit 5 Connecting the LEX unit to the REX unit 5 Checking the Installation 6 Connecting a USB Device 6 Troubleshooting 7 Specifications 9 Limited Hardware Warranty 1...

Страница 3: ...USB 2000 Notes ii...

Страница 4: ...al EXtender LEX unit Remote EXtender REX unit AC power adapter 2 units USB cable 2m long To complete the installation you will also require the following items that are not included with the product U...

Страница 5: ...ed up to 10km from the host computer The USB 2000 is composed of two individual units the LEX unit and the REX unit Note that there are no physical differences between the 2 and 4 units The only diffe...

Страница 6: ...u to connect up to four USB devices Additional devices may be connected by attaching a conventional USB hub to the REX unit The REX unit is powered by an external AC adapter Front View 6 5 Rear View 1...

Страница 7: ...ovide a duplex connection with crossover and must be terminated with Duplex LC connectors at both ends Fiber optic cable USB USB LEX REX cable cable s USB device s computer AC power adapters USB Cable...

Страница 8: ...the power adapter into a suitable AC outlet 3 Connect the power adapter to the LEX unit 4 Plug the Type B connector on the USB cable included into the Host port on the LEX unit 5 Plug the Type A conne...

Страница 9: ...patch cords must not exceed 10 000 meters NOTE The cabling must provide a duplex connection with crossover and must be terminated with Duplex LC connectors at both ends Checking the Installation 1 Ch...

Страница 10: ...cal power Link LEDs on LEX unit and REX unit are off Cause There is no connection between the LEX unit and the REX unit 1 Ensure that a fiber optic cable with crossover is connected between the LEX un...

Страница 11: ...vice does operate properly the first device may not be compatible with the USB 2000 Contact technical support for assistance All LEDs on both the LEX unit and REX unit are on but the device does not o...

Страница 12: ...Type B LEX unit connector downstream 1 x Duplex LC REX unit connector upstream 1 x Duplex LC REX unit connector downstream 4 x USB Type A LEX unit dimensions 107 mm x 84 mm x 34 mm 4 25 x 3 4 x 1 4 L...

Страница 13: ...2000Link cable not included Two strands of 9 125 m SMF cabling are required The cabling subsystem must provide a duplex connection with crossover and must be terminated with Duplex LC connectors at b...

Страница 14: ...tness for a particular purpose and non infringement of third party rights with respect to the hardware Icron Technologies Corporation dealer agent or employee is authorized to make any modification ex...

Отзывы: