Icron USB-2000 Скачать руководство пользователя страница 14

User Guide 

Limited Hardware Warranty 

Icron Technologies Corporation warrants that any hardware products 
accompanying this documentation shall be free from significant defects in 
material and workmanship for a period of one year from the date of 
purchase. Icron Technologies Corporation’s hardware warranty extends to 
Licensee, its customers and end users. 

Hardware Remedies 

Icron Technologies Corporation’s entire liability and the Licensee’s 
exclusive remedy for any breach of warranty, shall be, at Icron Technologies 
Corporation’s option, either (a) return of the price paid or (b) repair or 
replacement of hardware, which will be warranted for the remainder of the 
original warranty period or 30 days, whichever is longer. These remedies are 
void if failure of the hardware has resulted from accident, abuse, or 
misapplication. 

Limitation of Liability 

The hardware warranty set forth in this agreement replaces all other 
warranties. Icron Technologies Corporation expressly disclaims all other 
merchantability and fitness for a particular purpose and non-infringement of 
third-party rights with respect to the hardware. Icron Technologies 
Corporation dealer, agent, or employee is authorized to make any 
modification, extension, or addition to this warranty. Under no 
circumstances will Icron Technologies Corporation, its suppliers or licensors 
be liable for any costs of procurement or substitute products or services, lost 
profits, loss of information or data, or any other special, indirect, 
consequential, or incidental damages arising in any way out of the sale of, 
use of, or inability to use Icron Technologies Corporation product or service, 
even if Icron Technologies Corporation, its suppliers or licensors have been 
advised of the possibility of such damages. In no case shall Icron 
Technologies Corporation, its suppliers and licensors’ liability exceed the 
actual money paid for the products at issue. Because some jurisdictions do 
not allow the limitation of implied warranties of liability for incidental, 
consequential, special, or indirect damages, the above limitation may not 
always apply. The above limitations will not apply in case of personal injury 
where and to the extent that applicable law requires such liability. 

  

11 

Содержание USB-2000

Страница 1: ...which case the user will be required to correct the interference at his own expense CE Statement We Icron Technologies Corporation declare under our sole responsibility that the USB 2000 to which thi...

Страница 2: ...the LEX unit 5 Installing the REX unit 5 Connecting the LEX unit to the REX unit 5 Checking the Installation 6 Connecting a USB Device 6 Troubleshooting 7 Specifications 9 Limited Hardware Warranty 1...

Страница 3: ...USB 2000 Notes ii...

Страница 4: ...al EXtender LEX unit Remote EXtender REX unit AC power adapter 2 units USB cable 2m long To complete the installation you will also require the following items that are not included with the product U...

Страница 5: ...ed up to 10km from the host computer The USB 2000 is composed of two individual units the LEX unit and the REX unit Note that there are no physical differences between the 2 and 4 units The only diffe...

Страница 6: ...u to connect up to four USB devices Additional devices may be connected by attaching a conventional USB hub to the REX unit The REX unit is powered by an external AC adapter Front View 6 5 Rear View 1...

Страница 7: ...ovide a duplex connection with crossover and must be terminated with Duplex LC connectors at both ends Fiber optic cable USB USB LEX REX cable cable s USB device s computer AC power adapters USB Cable...

Страница 8: ...the power adapter into a suitable AC outlet 3 Connect the power adapter to the LEX unit 4 Plug the Type B connector on the USB cable included into the Host port on the LEX unit 5 Plug the Type A conne...

Страница 9: ...patch cords must not exceed 10 000 meters NOTE The cabling must provide a duplex connection with crossover and must be terminated with Duplex LC connectors at both ends Checking the Installation 1 Ch...

Страница 10: ...cal power Link LEDs on LEX unit and REX unit are off Cause There is no connection between the LEX unit and the REX unit 1 Ensure that a fiber optic cable with crossover is connected between the LEX un...

Страница 11: ...vice does operate properly the first device may not be compatible with the USB 2000 Contact technical support for assistance All LEDs on both the LEX unit and REX unit are on but the device does not o...

Страница 12: ...Type B LEX unit connector downstream 1 x Duplex LC REX unit connector upstream 1 x Duplex LC REX unit connector downstream 4 x USB Type A LEX unit dimensions 107 mm x 84 mm x 34 mm 4 25 x 3 4 x 1 4 L...

Страница 13: ...2000Link cable not included Two strands of 9 125 m SMF cabling are required The cabling subsystem must provide a duplex connection with crossover and must be terminated with Duplex LC connectors at b...

Страница 14: ...tness for a particular purpose and non infringement of third party rights with respect to the hardware Icron Technologies Corporation dealer agent or employee is authorized to make any modification ex...

Отзывы: