Connecting the TX unit to the RX unit  

 NOTE

To ensure proper operation, we recommend that only Category 5 or 
better, Unshielded Twisted Pair (UTP) cabling be used to connect 
the TX unit to the RX unit. The UTP cabling must have a straight-
through conductor configuration with no crossovers, and must be 
terminated with 8-conductor RJ45 connectors at both ends.  

With Surface Cabling 

1.  Remove the dust covers from the Link ports of the TX unit and the 

RX unit.  

2.  Plug one end of the first duplex multimode cable (not included) into 

the Link 1 port on the TX unit. Plug the other end of this cable into 
the Link 1 port on the RX unit. 

3.  Plug one end of the second duplex multimode cable (not included)  

into the Link 2 port on the TX unit. Plug the other end of this cable 
into the Link 2 port on the RX unit. 

4.  Plug one end of the Category 5 UTP cabling (not included) into the 

DDC port on the TX unit. Plug the other end of the Category 5 UTP 
cabling into the DDC port on the RX unit. 

With Premise Cabling 

1.  Remove the dust covers from the Link ports of the TX unit and the 

RX unit. 

2.  Plug one end of the first duplex multimode patch cord (not included) 

into the Link 1 port on the TX unit. Plug the other end of this cable 
into the first LC receptacle on the adjacent information outlet. 

3.  Plug one end of the second duplex multimode patch cord (not 

included) into the Link 2 port on the TX unit. Plug the other end of 
this cable into the second LC receptacle on the adjacent information 
outlet. 

4.  Plug one end of a Category 5 patch cord (not included) into the DDC 

port on the TX unit. Plug the other end of the patch cord into the 
RJ45 receptacle on the adjacent information outlet. 

5.  Plug one end of the third duplex multimode patch cord (not 

included) into the Link 1 port on the RX unit. Plug the other end of 
this cable into the first LC receptacle on the adjacent information 
outlet. 

Содержание DVI Ranger 500

Страница 1: ...DVI Ranger 500 User Guide Featuring ExtremeDVI Technology ...

Страница 2: ...ures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help CE Statement We Icron Technologies Corporation declare under our sole responsibility that the DVI Ranger to which this dec...

Страница 3: ...Begin 6 Installing the TX unit 6 Installing the RX unit 6 Connecting the TX unit to the RX unit 7 Completing the Installation 8 Troubleshooting 9 Specifications 11 Limited Hardware Warranty 12 Hardware Remedies 12 Limitation of Liability 12 Obtaining Warranty Service 13 Contacting Technical Support 13 ...

Страница 4: ...DVI Ranger 500 ii Notes ...

Страница 5: ...uded with the product DVI compatible computer or other video source DVI display Four strands of multimode fiber optic cable terminated at each end with duplex LC connectors if using surface cabling OR Four strands of multimode fiber optic cabling terminated at each end in duplex LC information outlets and four multimode fiber optic patch cables with duplex LC connectors if using premise cabling Ca...

Страница 6: ...dual units the TX unit and the RX unit Video signals in DVI format are transmitted from the TX unit to the RX unit over four strands of multimode fiber cable Information regarding the capabilities of the display such as its native resolution and refresh rate are conveyed from the RX unit to the TX unit over a Category 5 UTP cable in EDID DDC format The TX unit The TX unit connects to the video sou...

Страница 7: ...n to fiber network cable 4 Link 2 port Duplex LC receptacle for connection to fiber network cable 5 DDC port RJ45 receptacle for connection to copper network cable 6 DVI connector DVI D receptacle for connection to computer or other video source 7 Power connector Receptacle for connection of 12V DC power adapter NOTE The power adapter for the DVI Ranger 500 can be connected to either the TX unit o...

Страница 8: ...display 7 Power connector Receptacle for connection of 12V DC power adapter Network Cabling The TX unit and RX unit are interconnected by two sets of cables that perform separate functions Digital video signals are transmitted from the TX unit to the RX unit over four strands of multimode fiber cable The Digital Visual Interface DVI is composed of four separate video channels namely Red Green Blue...

Страница 9: ... the computer over the DVI cable In certain applications the EDID DDC function is not required In this situation the DDC cable can be omitted from the configuration and the system can be operated at the maximum range of the fiber connection 500 meters NOTE Category 5 UTP cabling is the standard data communications cable installed in most commercial and some residential buildings ...

Страница 10: ...t the two locations OR If you are using premise cabling ensure multimode fiber and Category 5 UTP cabling is installed between the two locations with duplex LC and RJ45 information outlets located near both the computer and the display Installing the TX unit 1 Place the TX unit near the computer 2 Switch off the computer 3 Connect the DVI output of the computer to the DVI port of the TX unit using...

Страница 11: ...y 5 UTP cabling not included into the DDC port on the TX unit Plug the other end of the Category 5 UTP cabling into the DDC port on the RX unit With Premise Cabling 1 Remove the dust covers from the Link ports of the TX unit and the RX unit 2 Plug one end of the first duplex multimode patch cord not included into the Link 1 port on the TX unit Plug the other end of this cable into the first LC rec...

Страница 12: ...t NOTE The maximum length of the Category 5 UTP cable including patch cords must not exceed 100 meters NOTE It is essential that the fiber connections are not crossed The left channel of Link 1 on the TX unit must be connected to the left channel of Link 1 on the RX unit and so on Completing the Installation 1 Connect the AC power adapter to either the TX unit or RX unit as convenient Connect the ...

Страница 13: ...Category 5 UTP cable with straight through conductors is connected between the TX unit and RX unit 2 Connect a short Category 5 patch cord between the TX unit and RX unit Recheck the operation of the system Status LED on RX unit is off Cause a There is no fiber connection between the TX unit and RX unit b There is no active video source connected to the TX unit 1 Ensure that multimode fiber cables...

Страница 14: ... Power the display OFF then ON again 5 Do not remove the DVI cable from the TX unit during normal operation Display is distorted or noisy Cause The screen resolution is not set properly 1 On the host computer open the display properties dialog and select the Settings tab Ensure that the resolution is set to UXGA 1600 x 1200 at 60 Hz refresh rate or a lesser value 2 Reset the system Display does no...

Страница 15: ...e positive TX unit connector upstream 1 x DVI D receptacle TX unit connectors downstream 1 x RJ45 receptacle 2 x Duplex LC receptacle RX unit connector upstream 1 x RJ45 receptacle 2 x Duplex LC receptacle RX unit connector downstream 1 x DVI D receptacle TX unit dimensions 107 mm x 80 mm x 26 mm 4 2 x 3 2 x 1 0 TX unit weight 0 3 kg 0 6 lb RX unit dimensions 107 mm x 80 mm x 26 mm 4 2 x 3 2 x 1 0...

Страница 16: ...and fitness for a particular purpose and non infringement of third party rights with respect to the hardware Icron Technologies Corporation dealer agent or employee is authorized to make any modification extension or addition to this warranty Under no circumstances will Icron Technologies Corporation its suppliers or licensors be liable for any costs of procurement or substitute products or servic...

Страница 17: ...d to you at Icron Technologies Corporation s expense not later than thirty days after Icron Technologies Corporation receives the defective product Address the returned product to RMA Coordinator Icron Technologies Corporation 4664 Lougheed Highway Suite 275 Burnaby BC V5C 5T5 Canada Tel 604 638 3920 Contacting Technical Support If you require technical assistance send an e mail message to techsup...

Страница 18: ...DVI Ranger 500 14 Notes ...

Страница 19: ...User Guide 15 Notes ...

Страница 20: ...90 00134 A01 Icron Technologies Corporation 4664 Lougheed Highway Suite 275 Burnaby BC V5C 5T5 Canada Tel 604 638 3920 Fax 604 638 3930 www icron com ...

Отзывы: