background image

 

 

 

 

 

 

 

HD IR Speed Dome User

’s Manual 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Version 1.0.0 

 

Содержание ICIP-P2300Y-IR

Страница 1: ...HD IR Speed Dome User s Manual Version 1 0 0 ...

Страница 2: ... 1 2 7 Auto Pattern 1 1 2 8 Privacy Masking 1 1 2 9 Auto Flip 1 1 2 10 Self diagnosis 1 1 2 11 Day Night Mode B W Color Mode 2 1 2 12 Auto Focus 2 1 2 13 Backlight Compensation 2 1 2 14 Pan Tilt and Zoom 2 1 2 15 3D Intelligent Positioning 2 1 2 16 Idle Status 2 1 2 17 Image Stabilizer Flip 2 2 QUICK CONFIGURATION TOOL 3 2 1 Overview 3 2 2 Operation 3 3 WEB OPERATION 6 3 1 Network Connection 6 3 2...

Страница 3: ...ng 12 4 4 4 Function Setting 18 4 4 5 IR Light Setting 26 4 5 Abnormity Handling 26 5 CABLE CONNECTION 27 5 1 Combination Cable Connection 27 5 2 System Layout 28 5 2 1 System Connection 28 5 2 2 Alarm Connection 28 6 FAQ 29 6 1 Daily Maintenance 29 6 2 Problems and Solutions 29 7 APPENDIX Ⅰ LIGHTNING PROOF AND SURGE PROTECTION 30 8 APPENDIX 2 TOXIC OR HAZARDOUS MATERIALS OR ELEMENTS 31 ...

Страница 4: ...reference tool for the operation of your system Here you can find information about this speed dome features and functions as well as a detailed menu tree Please keep it well for future reference Before installation and operation please read the following safeguards and warnings carefully ...

Страница 5: ...rotection cover there are no parts inside the SD for users to repair by themselves 6 Environment This series product should be installed in a cool dry place away from direct sunlight inflammable explosive substances and etc Please keep it away from the electromagnetic radiation object and environment Please keep the sound ventilation Do not allow the water and other liquid falling into the device ...

Страница 6: ...ay result in lens damage or it may adversely affect the device performance If there is too much dust please use the water to dilute the mild detergent first and then use it to clean the device Finally use the dry cloth to clean the device 8 About Accessories Always use all the accessories recommended by manufacturer Before installation please open the package and check that all the components are ...

Страница 7: ...d becomes slower when the zoom speed increases and the movement speed becomes higher when the zoom speed decreases 1 2 3 OSD It can display the called preset and preset ID speed dome title speed dome system temperature speed dome location coordinates when touring via menu setting 1 2 4 Preset Setup and Call Preset function is to save the address information such as PTZ pan tilt focus and etc to th...

Страница 8: ...produce a more vivid picture 1 2 14 Pan Tilt and Zoom Supports zoom in and zoom out during tilt and pan movement You can still get vivid image even you set auto focus and auto iris during this period 1 2 15 3D Intelligent Positioning Support 3D intelligent positioning function The speed dome can auto track to the specified zone 1 2 16 Idle Status When there is no available order for specified dura...

Страница 9: ...d etc Figure 2 1 Select one IP address and then right click mouse you can see an interface is shown as in Figure 2 2 Note You can set the IP address subnet mask and gateway for the network camera and PC Please note network camera IP address and PC IP address shall be in the same network segment if there is no router Network camera default IP address is 192 168 1 108 If there is a router please set...

Страница 10: ...IP address and then double click it to open the login interface Or you can select an IP address and then click the Login button to go to the login interface See Figure 2 4 In Figure 2 4 you can view device IP address user name password and port Please modify the corresponding information to login Please note the port information here shall be identical with the port value you set in TCP port in We...

Страница 11: ...guration tool main interface is shown as below See Figure 2 5 Figure 2 5 For detailed information and operation instruction of the quick configuration tool please refer to the Quick Configuration Tool User s Manual included in the resources CD ...

Страница 12: ...ase set the corresponding gateway and subnet mask Use order ping speed dome address to check connection is OK or not 3 2 Login and Logout Open IE and input speed dome address in the address bar For example if your speed dome IP is 192 168 1 108 then please input http 192 168 1 108 in IE address bar See Figure 3 1 Figure 3 1 System pops up warning information to ask you whether install control webr...

Страница 13: ...3 Please input your user name and password Default factory name is admin and password is admin Select the network connection type Note For security reasons please modify your password after you first login Figure 3 3 After you logged in you can see the main window See Figure 3 4 ...

Страница 14: ...8 Figure 3 4 Please refer to the Web Operation Manual included in the resource CD for detailed operation instruction ...

Страница 15: ... EXIT DISPLAY SETTING SYSTEM INFORMATION CAMERA SETTING FUNCTION SETTING WB SETTING EXPOSURE SETTING DAY NIGHT SETTING FOCUS SETTING IMAGE ADJUST DEFOG SETTING ZOOM SPEED NEXT PAGE BACK EXIT PRESET PAN AUTO SCAN AUTO TOUR AUTO PATTERN IDLE MOTION TIME TASK NEXT PAGE BACK EXIT IR LIGHT SETTING IR SENSITIVITY IR CONTROL RULE NEAR LIGHT FAR LIGHT IR LIGHT COMPENSATION BACK EXIT SYSTEM INFORMATION ADD...

Страница 16: ... the control keyboard or the matrix host to control the device please make sure the control parameter of the keyboard or the matrix host is the same with the speed dome OSD including address baud rate parity Please make sure the cable connection is OK 4 3 Main Menu You can open the IP dome menu via control keyboard matrix or speed dome control terminal Control the speed dome via control keyboard m...

Страница 17: ...ubmenu Please use the left right button on the keyboard or in the speed dome terminal menu to set After completed setup please click save button to save current setup SYSTEM INFORMATION Move the cursor to SYSTEM INFORMATION and then click confirm button to go to the third submenu ADDR INFORMATION Move the cursor to SITE INFORMATION and then click confirm button to go to the third submenu SYSTEM TI...

Страница 18: ...eset section to set corresponding preset value and preset title AZIMUTH DISP Display dome current coordinates or not Please use the left right button on the keyboard or in the speed dome terminal menu to set TIME DISP Display dome system time or not Please use the left right button on the keyboard or in the speed dome terminal menu to set POSITION Display the angel between the benchmark and then c...

Страница 19: ...e value the faster the speed Please use the left right button on the keyboard or in the speed dome terminal menu to set NEXT PAGE It includes the following options DIGITAL ZOOM PICTURE FLIP FREEZE FUNCTION STABLE CAMERA FACTORY DEFAULT SETUP and CAMERA RESTART Please use the left right button on the keyboard or in the speed dome terminal menu to set APERTURE SETTING It is to adjust the lens to ach...

Страница 20: ... camera gain Please use the left right button on the keyboard or in the speed dome terminal menu to set SHUTTER It is to set camera shutter speed Please use the left right button on the keyboard or in the speed dome terminal menu to set IRIS SETTING It is to set camera iris value Please use the left right button on the keyboard or in the speed dome terminal menu to set EXPOSURE COM It is to set ca...

Страница 21: ... click the left right button to set AE RECOVERY Manually click the and button on the PTZ interface system cam resume previous exposure value after specified time The exposure value does not resume if this function is off WDR SETTING It is an abbreviation for wide dynamic region Please make sure your camera supports current function This function can adjust the video brightness when the contrast be...

Страница 22: ... to save button to save current setup SENSITIVITY It is to set the sensitivity of DAY NIGHT SAVE This button is for DAY TIME and NIGHT TIME setup After you set the day time or night time you need to move the cursor here and then click confirm button to save current time setup For other setups you do not need to use this button BACK Go back to previous menu EXIT Log out system menu 4 4 3 5 Focus Se...

Страница 23: ... right button on the keyboard or in the speed dome terminal menu to set INTENSITY It is valid when the defog mode is manual Please use the left right button on the keyboard or in the speed dome terminal menu to set LIGHT INTENSITY MODE It is to set air light intensity mode Please use the left right button on the keyboard or in the speed dome terminal menu to set LIGHT INTENSITY LEVEL It is to set ...

Страница 24: ... SETTING click confirm button You can see the above interface PRESET Move the cursor to PRESET and then click confirm button to go to the third submenu AUTO PAN Move the cursor to PAN and then click confirm button to go to the third submenu AUTO SCAN Move the cursor to SCAN and then click confirm button to go to the third submenu AUTO TOUR Move the cursor to TOUR and then click confirm button to g...

Страница 25: ...t the monitor zone Please move the cursor to setting and click confirm button The system will pop up a message PRESET Here means preset number And the SETTING column pops up an OK Now you successfully added a preset Please note you need to enable display preset title function first Main menu display setting preset title Repeat the above procedures to set more presets Once you want to modify a pres...

Страница 26: ...CAN button and then click confirm button AUTO SCAN NO Here is to set auto scan number Please use the left right button on the keyboard or in the speed dome terminal menu to set SET LEFT LIMIT Here is to set camera left address Click confirm button to save current setup SET RIGHT LIMIT Here is to set camera right address Click confirm button to save current setup SCAN SPEED Please use the left righ...

Страница 27: ...the tour Please use up down button to set preset number dwell time and speed Use the left right button to go to the next tour Click confirm button you can exit the setup After you completed the setup move the cursor to back button to go to the previous interface DELETE TOUR Here is to delete a tour Input tour number in TOUR NO and then move the cursor to DELETE TOUR click confirm button to delete ...

Страница 28: ...on System stops current pattern BACK Go back to previous menu EXIT Log out system menu Note The dwell time between two orders should be less than one minute otherwise system will set to default value as one minute After click PROGRAM STOP do not click CALL button before icon disappears completely Any manual operation during the pattern procedure will terminate current dome pattern operation 4 4 4 ...

Страница 29: ... the task begin time Move the cursor to current item and then click confirm button to set the time Please use the up down button to set the detailed value and then use left right button to go to the next setup item After you completed the setup please click confirm button to exit start time setup and then move the cursor to the SAVE button to save current setup END TIME Here you can set the task e...

Страница 30: ...It is to set the password to go to the PTZ menu Click the confirm button to go to the next interface To set MENU IDLE If current setup is ON once you open the menu and leave it idle for specified period the menu may automatically disappear If current setup is OFF the menu is always there and will not disappear Please use the left right button to set PTZ AUTO STOP The speed dome will stop all the P...

Страница 31: ... set privacy mask zone Please use the left right button on the keyboard or in the speed dome terminal menu to set You can call corresponding privacy mask zone number if you have successfully set one PRIVACY MASKING There are two settings on and off Please go to the corresponding privacy mask zone and click left right button to set SIZE It is to adjust the privacy zone size Move the cursor to curre...

Страница 32: ...nu of the speed dome IR SENSITIVITY It is to set the IR SENSITIVITY The bigger sensitivity value is the higher sensitivity will be click left right button to set IR LIGHT CONTROL RULE It is to set the IR light control rule it can be set as zoom priority and manual click left right button to set NEAR LIGHT It is to set near light brightness click left right button to set Note It is only valid when ...

Страница 33: ...Name Function POWER GND Power port Connect to the power cable GND ground end 485A 485B RS485 remote control AUDIO OUT Audio output port GND Ground port IN Audio input port VIDEO GND Ground port OUT Video output port RJ45 Network port Connect to network cable and HI PoE ALARM IN Seven alarm input channels It is to receive relay signal from the external alarm source You can go to dome menu to activa...

Страница 34: ...s NO Note The default setup 1 channel alarm output 2 channel alarm output optional 5 2 System Layout 5 2 1 System Connection Please refer to Figure 5 1 for system connection information Figure 5 1 5 2 2 Alarm Connection Please refer to Figure 5 2 for alarm connection information Figure 5 2 Network Output AC220V Input Transformer DVR P C Power Output ...

Страница 35: ... transformer Red LED light on the power board is on Power supplying is low Something wrong with power board Use multimeter to check dome load Please contact retailer to replace power board 2 No self diagnosis There is a noise Power supplying is inadequate Replace power supplying Mechanical malfunction Need electrical engineer help 3 Video signal is not successive Circuit connection is too loose Co...

Страница 36: ... one point to the earth Open floor cable layout is forbidden In area of strong thunderstorm hit or near high sensitive voltage such as near high voltage transformer substation you need to install additional high power thunder protection device or lightning rod The thunder protection and earth of the outdoor device and cable shall be considered in the building whole thunder protection and conform t...

Страница 37: ...Indicates that the concentration of the hazardous substance of at least one of all homogeneous materials in the parts is above the relevant threshold of the SJ T11363 2006 standard During the environmental friendly use period EFUP period the toxic or hazardous substance or elements contained in products will not leak or mutate so that the use of these substances or elements will not result in any ...

Страница 38: ...tware here are subject to change without prior written notice All trademarks and registered trademarks are the properties of their respective owners If there is any uncertainty or controversy please refer to the final explanation of us Please visit our website or contact your local service engineer for more information ...

Отзывы: