background image

Quick Start Guide

HD-AVS Dome

PTZ Camera

Features and Specifications

A.

Overview

B.

Cable Interface

Camera Installation

A.

Installation Steps

B.

Dip switch diagram

OSD and PTZ Functions

A.

OSD Operation

B.

OSD Menu Functions

C.

Function Settings

FAQ and Lightning Protection

A.

FAQ 

B.

Lightning Protection

2

2

3-4

5

5

6

6-7

8

8-9

Table Of Contents

MARGIN

GUIDES

To see the guides to go:

View / Guides / Show 

Guides

www.icrealtime.com

IMPORTANT SAFEGUARDS AND WARNINGS

Electrical Safety 

All  installation  and  operation  here  should  conform  to  your  local  electrical  safety  codes.  The 

power  shall  conform  to  the  requirement  in  the  SELV  (Safety  Extra  Low  Voltage)  and  the 

Limited power source is rated  DC12V/5A ± 25% (See product datasheet for the most accurate 

power  requirement  specification).  We  assume  no  liability  or  responsibility  for  all  the  fires  or 

electrical shock caused by improper handling or installation. We are not liable for any problems 

caused by unauthorized modification or attempted repair.

Transportation Security 

Care  must  be  given  to  avoid  heavy  stress,  violent  vibration  or  water  damage  during 

transportation, storage and installation.

Installation

Do  not  apply  power  to  the  camera  before  completing  installation.  Please  install  the  proper 

power cut-off device during the installation connection. Always follow the instruction guide the 

manufacturer recommended. 

Qualified engineers needed

All the examination and repair work should be done by the qualified service engineers. We are 

not liable for any problems caused by unauthorized modifications or attempted repair.

Environment

This series network camera should be installed in a cool, dry place away from direct sunlight, 

inflammable,  explosive  substances  and  etc.  Please  keep  it  away  from  the  electromagnetic 

radiation object and environment. Please make sure the CCD (CMOS) component is out of the 

radiation of the laser beam device. Otherwise it may result in CCD (CMOS) optical component 

damage. Please keep the sound ventilation. Do not allow the water and other liquid falling into 

the camera. Lightning-proof device is recommended to be adopted to better prevent lightning 

damage.  The  grounding  studs  of  the  product  are  recommended  to  be  grounded  to  further 

enhance the reliability of the camera.

Daily Maintenance 

Please  shut  down  the  device  and  then  unplug  the  power  cable  before  you  begin  daily 

maintenance work. Do not touch the CCD (CMOS) optic component. You can use the blower to 

clean the dust on the lens surface. Always use the dry soft cloth to clean the device. If there is 

too much dust, please use the water to dilute the mild detergent first and then use it to clean 

the device. Finally use the dry cloth to clean the device. Please put the dustproof cap to protect 

the CCD (CMOS) component when you do not use the camera. 

Accessories

Be sure to use all the accessories recommended by manufacturer. Before installation, please 

open the package and check all the components are included. Contact your local retailer ASAP 

if something is broken in your package. 

Содержание HD-AVS

Страница 1: ...ne by the qualified service engineers We are not liable for any problems caused by unauthorized modifications or attempted repair Environment This series network camera should be installed in a cool dry place away from direct sunlight inflammable explosive substances and etc Please keep it away from the electromagnetic radiation object and environment Please make sure the CCD CMOS component is out of...

Страница 2: ...le choice for outdoor environments Note Take careful steps when handling the camera See figure 1 1 1B Cable Interface See Figure 1 2 1 FC Connector 2 DC Power input 3 24VAC input Red Black Yellow Green ground 4 RS485 Yellow A Orange B 5 Video output 6 Ethernet port on some models 7 Audio IO White Input Red Output Black Ground 8 Alarm IO Blue Alarm output 1 Black Alarm output 2 Green Contac switch 1...

Страница 3: ...p See Figure 2 1 Step 2 For outdoor installation four rubber grommets are provided for the mounting screws to waterproof the base See Figure 2 2 Step 3 Remove the dome cover using the wrench provided Thread the cabling through the cable exit on the installation surface and install the mounting screws as shown in Figure 2 3 Step 4 Connect the necessary cabling to the camera See Figure 2 4 Figure 2 ...

Страница 4: ...4 www icrealtime com Step 5 Replace and secure the dome cover as shown in Figure 2 5 Step 6 It is recommended to waterproof any outdoor cabling See Figure 2 6 Figure 2 5 Figure 2 6 ...

Страница 5: ...u Camera PTZ Make sure the Channel the PTZ is occupying is set to AVS mode Step 1 Using a mouse and a local display right click on the live view and select PTZ control The PTZ menu will populate See Figure 3 1 Step 2 Click to open PTZ Control Panel then click to open OSD The Use the up and down buttons to select menu item and the left and right to change parameter values Click Enter to confirm See ...

Страница 6: ...etting Preset Auto Pan Auto Scan Tour Pattern Idle Motion Auto Run Privacy Masking PTZ Speed Set Zero Power Up Menu Password Menu Idle Channel Title PTZ Auto Stop Warm Machine PTZ Correction Alarm Setting Alarm No Action Parameter Contact Relay Out Reset Delay IR Light Setting IR Sensitivity IR Light Ctrl Near Light Far Light IR Light Comp 3C Function Settings Presets These are positions the PTZ c...

Страница 7: ...tern This a recorded set of movements that the PTZ will follow Pattern No You can select different scan numbers to modify Program Start This records the pattern movement Click Enter to start An OK will flash indicating the PTZ movements will now be recorded Move the PTZ as desired Program End Select this option after you have finished recording your pattern Call Starts the recorded pattern movement ...

Страница 8: ... the speed dome in an outdoor environment The signal transmission cable and high voltage device or high voltage cable should be at least 50 meters apart If possible route cables through a properly grounded and shielded underground conduit In areas of strong lightning occurrence or near high sensitive voltage such as near high voltage transformer substation it is required to install additional a hi...

Страница 9: ...9 www icrealtime com Figure 5 1 Figure 5 2 4B LIGHTNING PROOF AND SURGE PROTECTION Continued ...

Отзывы: