background image

 

 23

 

PARTS LIST 

 

With variable speed motor (ECM) 

 

 
 

B50092B 

ITEM

PART #

DESCRIPTION

COMMENTS

1

B03622

HEAT EXCHANGER

Heat exchanger only

2

J06L002

SEAL STRIP, DIA 1/8 x 25'

3

B03652-01

FRONT PANEL ASSEMBLY (RIGHT)

Panel, insulation and labels included

4

B03667

FRONT PANEL INSULATION

5

B03637-01

BAFFLE, LATERAL

6

B03651-01

SIDE PANEL ASSEMBLY

Panel, insulation and baffle included

7

B03666

SIDE PANEL INSULATION

8

B03455-01

ELECTRICAL KIT, BVSO INT.

9

F06F015

WASHER, ZINC 1 7/16"

10

Z99F061

OBSERVATION PORT

11

R02R004

HIGH LIMIT 195-30F,  7"

12

B03453

ELECTRICAL KIT, TT

13

B03454

ELECTRICAL KIT, BURNER

14

B03642

WIRE CHANNEL (BVSO/SWITCH)

15

B03630-01

BAFFLE

One baffle included

16

B03675

SMOKE OUTLET GASKET

17

B03662

RADIATOR BAFFLE

Item # 16 included

18

F07O001

FLANGE NUT, HEXAGONAL 3/8-16NC BRASS

19

F07F011

HEX NUT 3/8-16NC ZINC  

20

B01684

COVER, ELECTRICAL BOX

21

Z99F050

HANDLE , RECESSED BLACK

22

B03654-01

BLOWER DOOR ASSEMBLY

Door and labels included

23

B03680-02

REPLACEMENT BLOWER ASSEMBLY

Blower, motor and capacitor included

24

Z06G001

BLOCKED VENT SHUT-OFF BVSO-225

25

B03118-01

ELECTRICAL KIT, BVSO EXT.

26

L04I013

STRAIN RELIEF BUSHING

27

L04J001

CABLE CLAMP, 9/16" WHITE

28

B03640

WIRE CHANNEL, INT.

29

B03636

BLOWER DIVIDER

30

B30513

BLOWER SLIDE

One blower slide included

31

B03637-02

LATERAL BAFFLE

32

B03480-01

FILTER RACK KIT

33

B03635

FLOOR

34

B03651-02

SIDE PANEL ASSEMBLY (LEFT)

Panel, insulation and baffle included

35

B03653

REAR PANEL ASSEMBLY

Panel, insulation and baffles included

36

B03665

REAR PANEL INSULATION

37

B03638

REAR BAFFLE

38

B01682

SUPPORT, ELECTRONICS BOX

39

L01F009

TRANSFORMER, 120-24Volt, 40VA

40

B01683

ELECTRICAL BOX

41

R99G003

ELECTRONIC BOARD, UTEC 1168

42

B01888

MOTOR SUPPORT ASSEMBLY                         

Legs, band and hardware included

43

B03669

ELECTRICAL KIT, BOARD

44

B03242

ELECTRONIC KIT, BLOWER

45

B03243

ELECTRICAL KIT, BLOWER

46

B03720-04

BLOWER, 100-10T DD 0.50 PP

Housing & wheel only

47

L06H018

MOTOR 1/2 HP ECM

Item #48 and #49 included

48

L06H016

MOTOR 1/2 HP ECM WITHOUT MODULE

49

N/A

MOTOR MODULE ECM

50

Z01L004

BLOWER WHEEL, 10-10 CLW CV

51

R02R007

HIGH LIMIT 120-20F, 1.75'' 

52

B03641

BLOWER SLIDE

One blower slide included

445 01 4101 00

Содержание OMF112K14A

Страница 1: ...HE INFORMATION IN THIS MANUAL FOR THE INSTALLATION SERVICING OF THE FURNACE AND KEEP THE DOCUMENT NEAR THE UNIT FOR FUTURE REFERENCE HOMEOWNER PLEASE KEEP THIS MANUAL NEAR THE FURNACE FOR FUTURE REFER...

Страница 2: ...LE SPEED MOTORS 9 2 13 INSTALLATION OF ACCESSORIES 9 3 OPERATION 10 3 1 START UP 10 3 2 OPERATING SEQUENCE OIL HEATING MODE 10 3 3 CHECKS AND ADJUSTMENTS 10 4 MAINTENANCE 12 4 1 CLEANING THE HEAT EXCH...

Страница 3: ...on such as the model and serial numbers of the furnace WARNING Installations and repairs performed by unqualified persons can result in hazards to them and to others Installations must conform to loca...

Страница 4: ...t designed for outdoor installation It must be installed in such a manner as to protect its electrical components from water Outdoor installation will lead to a hazardous electrical condition and to p...

Страница 5: ...f bodily harm if ever an electrical problem develops A green ground screw is supplied with the control box for that purpose The appliance must be installed in accordance with the current ANSI NFPA 70...

Страница 6: ...e burner for the first time adjust the air and turbulator settings to those listed in this manual Once the burner becomes operational final adjustments will be required Refer to section 3 of this manu...

Страница 7: ...Test The purpose of the following test is to check that the electrical outlet on the furnace designated to the BVSO is functional 1 Start up the burner 2 Remove the three pole plug from the BVSO outle...

Страница 8: ...istance 2 10 DUCTING WARNING Poisonous carbon monoxide gas hazard DO NOT draw return air from inside a closet or utility room Return air MUST be sealed to the furnace casing Failure to properly seal d...

Страница 9: ...GPH OFF OFF A 0 68 ON OFF B 0 80 OFF ON C ALL ON ON D ALL 2 13 INSTALLATION OF ACCESSORIES WARNING Electrical shock hazard Turn OFF electrical power at the fuse box or service panel before making any...

Страница 10: ...are appropriate and according to the specifications in this manual 8 The blower start stop delays are satisfactory 9 The thermostat of the room is in the heating mode and is set higher than the ambie...

Страница 11: ...bove the burner is a measurement necessary to determine if there is a blockage in the heat exchanger or the flue pipe Refer to the Technical Specifications in this manual for overfire pressure values...

Страница 12: ...combustion chamber should be inspected to determine if replacement is required 8 After the cleaning replace the heat exchanger baffles flue collar plate and oil burner 9 Readjust the burner for proper...

Страница 13: ...ephone Day Night Dealer name and address START UP RESULTS Nozzle Pressure lb po 2 Burner adjustments Primary air Fine air Drawer Assembly CO2 Smoke scale Bacharach Gross stack temperature F Ambient te...

Страница 14: ...n 85 2 85 0 85 2 85 0 RIELLO BURNER MODEL 40 BF5 Direct vent DV Burner tube insertion length inches Nozzle Delavan 0 60 70A 0 70 70A 0 60 70A 0 70 70A Minimum and Maximum pump pressure PSIG 130 to 160...

Страница 15: ...me ShortRun On Delay CFM Level Time Off Delay CFM Level Time A 1 OFF 2 OFF 0 68 13 45 sec 19 60 sec 38 3 min B 1 ON 2 OFF 0 80 13 45 sec 19 30 sec 38 3 min C 1 OFF 2 ON All 13 45 sec 100 0 sec 100 2 m...

Страница 16: ...ACE 1 5 08 cm 2 2 54 cm 1 5 08 cm 2 BOTTOM FURNACE 2 2 54 cm 1 3 5 08 cm 2 4 BACK FURNACE OPPOSITE SIDE OF THE BURNER 1 7 62 cm 3 7 62 cm 3 7 62 cm 3 PLENUM OR HORIZONTAL WARM AIR DUCT WITHIN 6 ft OF...

Страница 17: ...17 Figure 5 Furnace dimensions 445 01 4101 00...

Страница 18: ...18 Figure 6 Wiring Diagram 4 Speed Motor PSC 445 01 4101 00...

Страница 19: ...19 Figure 7 Wiring Diagram Variable Speed Motor ECM 445 01 4101 00...

Страница 20: ...20 PARTS LIST With 4 Speed motor PSC B50091B 445 01 4101 00...

Страница 21: ...MBLY Blower motor and capacitor included 24 Z06G001 BLOCKED VENT SHUT OFF BVSO 225 25 B03118 01 ELECTRICAL KIT BVSO EXT 26 L07F003 ROCKER SWITCH DPST 27 L04I013 STRAIN RELIEF BUSHING 28 L04J001 CABLE...

Страница 22: ...22 PARTS LIST With variable speed motor ECM B50092B 445 01 4101 00...

Страница 23: ...EMBLY Blower motor and capacitor included 24 Z06G001 BLOCKED VENT SHUT OFF BVSO 225 25 B03118 01 ELECTRICAL KIT BVSO EXT 26 L04I013 STRAIN RELIEF BUSHING 27 L04J001 CABLE CLAMP 9 16 WHITE 28 B03640 WI...

Отзывы: