Страница 1: ...tes follow all safety codes including the current edition National Fuel Gas Code NFGC NFPA No 54 ANSIZ223 1 In Canada refer to the current edition of the National Standard Canada CAN CGA B149 1 and 2...

Страница 2: ...r Type and Size Fan Time ON Setting Fan Time OFF Setting Manual Gas Shut Off Upstream of Furnace Drip Leg YES _1 NO _1 Dealer Comments Drip Leg Upstream of Gas Valve Condensate Drain Connected YES _ C...

Страница 3: ...lified service technician to inspect the unit and to replace any part of the control system and any gas control which has been under water 3 Never obstruct the vent grilles or any ducts that provide a...

Страница 4: ...ntilation Air section Contaminated Combustion Air Dimensions and Clearances Upflow Horizontal NTG3 NTN3 FBF NBF rain 25 22 28 MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS FOR ALL UNITS REAR 0 FRONT 3 R...

Страница 5: ...th accessory Masonry Chimney drafthood kit installed I I I I DIMENSIONAL INFORMATION MODEL Drawing is representative some models may vary GAS CONNECTION CABINET A I B C I 40 I 151 2 281 2 40 I 191 8 2...

Страница 6: ...BINET A B C 15t 2 281 2 40 19t 8 281 2 40 223 4 28t 2 40 BOTTOM RETURN OPENING F G 14 1817 32 179 16 1817 32 213 16 1817 32 OPENING D E 14 15t 2 179 16 15 t 2 213 16 151 2 GAS CONNECTIONS H J K 9t3 t6...

Страница 7: ...yond the front of the furnace louver door This is a recommendation only not a requirement This furnace MUST NOT be installed directly on wood flooring or supports carpeting tile or other combustible m...

Страница 8: ...or openings 2 Figure 6 illustrates how to provide combustion and ventila tion air A minimum of two permanent openings one inlet and one outlet are required Outside Air This is ONLY a guide Subject to...

Страница 9: ...ts between wall panels at penetrations for plumbing electrical and gas lines etc VentilationAir Some provincial codes and local municipalities require ventilation or make up air be brought into the co...

Страница 10: ...tion air Ventingto Existing MasonryChimney NOTE The tables and notes referred to below are found in the most recent printing of the United States National Fuel Gas Code venting tables Use the United S...

Страница 11: ...removing two screws Set aside screws 5 Detach field connect box from top panel by removing two screws Set aside screws Remove four screws holding top panel to casing Remove top panel Discard top pane...

Страница 12: ...ual Fire Explosion Poison carbon monoxide gas haz ard This conversion shall be done by a qualified ser vice agency in accordance with the Manufactur er s instructions and all applicable codes and re q...

Страница 13: ...55 55 55 55 NOTE NATURAL GAS DATA BASED ON 0 60 SPECIFIC GRAVITY PROPANE DATA BASED ON 1 53 SPECIFIC GRAVITY FOR FUELS WITH DIFFERENT SPECIFIC GRAVITY CONSULT THE LATEST EDITION OF THE NATIONAL FUEL G...

Страница 14: ...gas meter or LP second stage reg ulator Fire or explosion hazard The flexible corrugated metal gas connector must be properly installed cannot go through the side of the furnace and can not be used i...

Страница 15: ...Set thermostat heat anticipator in accordance with the Technical Support Manual OptionalEquipment All wiring from furnace to optional equipment MUST conform to local codes or in the absence of local c...

Страница 16: ...ide furnace area seal return air duct to furnace casing and terminate duct out side furnace space When a refrigeration coil is used in conjunction with this unit it must be installed on the discharge...

Страница 17: ...on a col box cased col NOTE The 20 x 25 standoff filter rack gives more filter area but does not provide more air To achieve 2000 CFM a bottom return or 2 side returns are still needed NOTE Disposable...

Страница 18: ...or and the plenum 2 3 4 Fabricate the plenum to the dimensions given in Table 6 Note that the dimensions given are outside dimensions Set the base over the opening in the floor centering the open ing...

Страница 19: ...ut of rack at top of furnace 3 Straighten up filters and pull straight down at side of blower Pull out through right door opening 4 Vacuum clean or wash with warm water and dry thoroughly before repla...

Страница 20: ...ner flames are noted it may be nec essary to adjust gas pressures or check for drafts Main Burner 10 10 78 TemperatureRiseCheck The blower speed MUST be set to give the correct air temperature rise th...

Страница 21: ...me If it is necessary to operate the heating speed and continuous blower speed using the same blower speed connect a jumper be tween the Neat and Cont terminals on the electronic fan con trol Note The...

Страница 22: ...75F16G1 GDE100F14G1 GDE100F20G1 GDE125J20G1 Models NTN3050FBG1 NTN3075FBG1 NTN3075HFG1 NTN3100KFG1 NTN3100KJG1 NTN3100LJG1 NTN3125KJG1 NTN3125LJG1 NTG3050FBG1 NTG3075FBG1 NTG3075HFG1 NTG3100GFG1 NTG31...

Страница 23: ...8600 HW 8600 HW 8600 HW 8600 HW 8600 Lock Out Time NA NA NA NA NA NA NA NA Combustion FlueOutlet Size Inches 3 3 3 3 3 3 3 3 Std OutletTemp F 480 480 480 480 480 480 480 480 Limits Controls Thermal Se...

Страница 24: ...NA NA Limits Controls Thermal Sensor F 300 300 300 300 300 300 LimitControlSetting F See Parts Ust See PartsList See Parts List See PartsList See PartsList SeeParts List Auxiliary Limit F 110 110 110...

Страница 25: ...gnitionType SeriesHoneywell HSP HSP HSP HSP HSP HSP HSP Lock Out Time NA NA NA NA NA NA NA Combustion FlueOutlet Size Inches 3 3 3 3 3 3 3 Std OutletTemp F 480 480 480 480 480 480 480 Limits Controls...

Страница 26: ...3 3 3 3 3 3 3 Std OutletTemp F 480 480 480 480 480 480 480 Limits Controls Thermal Sensor F 300 300 300 300 300 300 300 LimitControlSetting F See PartsList See Parts List See PartsList See PartsList...

Страница 27: ...47 727 788 E_ _ 50 622 700 755 w 60 590 661 717 70 558 624 673 NTN3100KFA NBF100F20A NTN3100KJA NBF100J20A NTG3100KFA FBF100F20A NTC6100KJ GNE100J20 NTC6100KJ GNE100J20 Air Delivery in Cubic Feet per...

Страница 28: ...s Per Second L S Furnace Rated 0 5 WC ESP LOW MED L MED MED H 318 405 479 312 399 472 307 387 461 300 375 449 287 361 431 266 347 411 243 323 386 NDN3075HF NDF075F16F NDN6075HF GDE075F16F Air Delivery...

Страница 29: ...1592 40 735 989 1255 1546 _ 50 704 968 1218 1502 60 668 941 1171 1425 w 70 646 881 1100 1353 NTC6100KF GNE100F20 NTN6100KF NNE100F20 Air Delivery in Cubic Feet per Minute C F M _ Furnace Rated 0 5 WC...

Страница 30: ...ES DEPENDING ON MODEL SPEED TAP CODE BLACK H_ BLUBMLO ORANGE MHF RED LO LINE VOLTAGE FACTORY LiNE VOLTAGE FIELD LOW VOLTAGE FACTORY LOW VOLTAGE FIELD _ INTERNAL CiRCUiT BOARD WiRiNG PRESSURE SWITCH 1...

Страница 31: ...13 NTG3 FBF NTN3 NBF B DD EE D E AA U 22 10 14 25 22 27 441 01 2603 02...

Страница 32: ...one24 19 CombustionBlowerAssemly 20 RoIIoutSwitch Limit 21 Switch Pressure 22 Heat ExchangerGaskets 23 Heat ExchangerFrtPartition Part Number 1011544 1012406 1012407 1011364 1011363 1012408 601210 600...

Страница 33: ...cket Control NN Partition Blower PARTNOT ILLUSTRATED WireHarnessAsy LowVolt Manual Homeowners Manual Installation Tech Part Number 1013295 1013296 1013297 1013298 1011941 1010360 1093661 1093662 10936...

Страница 34: ...4 19 CombustionBlowerAssem 20 Rollout Switch Limit 21 Switch Pressure 22 Heat ExchangerGaskets 23 Heat ExchangerFrt Partition Part Number 1011544 1012406 1012407 1011364 1011363 1012408 601210 600587...

Страница 35: ...NN Partition Blower PARTNOT ILLUSTRATED Wire HarnessAsy LowVolt Manual Homeowners Manual Installation Tech Part Number 1013295 1013296 1013297 1013298 1011941 1010360 1093661 1093662 1093663 1011047...

Страница 36: ...14 NDN3 NDF MM A S BB LL 19 22 20 22 25 23 14 441 01 2603 02...

Страница 37: ...mit 210 F 260 F 195 F 220 F 150 F 18 Tubing Silicone 24 19 CombustionBlwr Assb 20 RolloutSwitch Limit 21 Switch Pressure 22 Gasket Heat Exchanger 23 Partition Front HtExchanger Part Number 1011544 101...

Страница 38: ...eld PART NOTILLUSTRATED Wire Harness Manual Homeowners Manual Installation Manual TechSupport Part Number 1013299 1013302 1013300 1013301 1011941 1010360 1093661 1093662 1093663 1011047 1011050 101105...

Страница 39: ...EEN _G ILINE VOLTAGE FIELD ORANGE 0 I LOW VOLTAGE FACTORY REO R THERMOSTAT I LOW VOLTAGE FIELD WHITE INTERNAL CIRCUIT BOARD WIRIN YELLOW LADDER DIAGRAM NOT II5V BBHZ NEUTRAL odl J_ _ZNTERLOCK GNOo SWI...

Страница 40: ...NTC6 GNE NTN6 NNE EE AA J 16 22 14 25 22 29 _ 441 01 2603 02...

Страница 41: ...h Limit 21 Switch Pressure 22 Heat ExchangerGaskets 23 Heat ExchangerFrt Partition Part Number 1011544 1012406 1012407 1011364 1011363 1012408 1011366 601210 600587 1011420 1011433 1000735 1012514 101...

Страница 42: ...HarnessAsy LowVolt Fuse Manual Homeowners Manual Installation Tech Part Number 1013295 1013296 1013297 1013298 1011941 1010360 1093661 1093662 1093663 1011045 1011048 1011052 1011055 1011057 1011379...

Страница 43: ...0 F 18 Tubing Silicone24 19 CombustionBlowerAssembly 20 RolloutSwitch Limit 21 Switch Pressure 22 Heat ExchangerGaskets 23 Heat ExchangerFrontPartition 28 Ignitor Sensorwithclip Part Number 1011544 10...

Страница 44: ...QQ Cover BurnerBox RR Sightglass PARTNOTILLUSTRATED Wire HarnessAsy Low Volt Fuse 5Amp Manual Homeowners Manual Installation Tecb Part Number 1013295 1013296 1013297 1013298 1011941 1010360 1093661 10...

Страница 45: ...NDN6 GDE MM BB QQ UU 22 10 22 25 22 37...

Страница 46: ...RottoutSwitch Umit 21 Switch Pressure 22 Gasket Heat Exchanger 23 Partition FrontHtExchanger Part Number 1011544 1011364 1012406 1012407 1012408 601210 600587 1011420 1320368 1012514 1012119 1012513...

Страница 47: ...Box PARTNOT ILLUSTRATED Wire HarnessAsy Fuse Manual Homeowners Manual Installation Tech Part Number 1013299 1013302 1013300 1013301 1011941 1010360 1093661 1093662 1093663 1011047 1011050 1011053 1011...