Troubleshooting and fault elimination
iMAT 32VBI-ELV
23
Pos : 67 /Beko T ec hnis che D okumentati on/Übersc hriften/1/F ehlers uc he und Fehl erbehebung @ 0\mod_1183637945027_15098.doc x @ 15107 @ 1 @ 1
12 Troubleshooting and fault elimination
Pos : 68 /Beko T ec hnis che D okumentati on/Fehlers uc he/BEKOMAT /Fehl ersuc he BM 32U/32UV/33U/F ehl ers uche BM 32U /32U V/32U FM(K)/33U /33UV @ 4\mod_1357742330741_15098.doc x @ 29677 @ @ 1
Symptoms
Possible reasons
Measures
No LED lights up
Supply voltage incorrect
Circuit board defective
Check the voltage on the type plate
Check the connections and the supply
voltage
Check the circuit boards for possible
damage
All LEDs are continuously
on
Failure during the start of the
program
Circuit board defective
Separate the device from the supply
voltage and reactivate after > 5 s
Check the circuit boards for possible
damage
Test button pressed,
but no condensate
discharge
Feed pipe and/or discharge pipe
blocked or obstructed
Wear and tear
Circuit board defective
Service unit defective
Minimum pressure not reached
Maximum pressure exceeded
Check feed and discharge pipe
Check whether or not the valve opens
audibly (press the test button several
times for >2 seconds)
Check the circuit board for possible
damage
Check the operating pressure
Condensate discharge
only when the test
button is pressed
Feed pipe without sufficient slope
Cross section not large enough
Condensate accumulation too high
(surge)
Service unit extremely dirty
Install feed pipe with a slope
Replace the service unit
Device blows off
continuously
Service unit defective or dirty
Replace the service unit