C-9
ICP Flash Utility (IFU)
Example
The following example displays version information about all
supported controllers.
A:\> IFU VERSION /C 0
ICP Flash Utility V4.0-0 B5749
(c)ICP Inc. 1999–2005. All Rights Reserved.
Version Information for Controller #0 (ICP9024RO)
ROM: Build 5748 [VALID] Fri Sep 27 13:28:40 EDT 2002
A:\> IFU VERSION /C ALL
IFU Command Line – Step-by-Step
This section provides step-by step instructions for updating the
flash.
To update the flash using the IFU command line:
1
Create the firmware floppy disks, as described in
.
2
Shut down the computer.
3
Insert the bootable disk that contains the IFU utility.
4
Turn on the computer.
5
Enter the system setup utility and verify that your computer is
set up to boot from the bootable disk.
6
If you have multiple controllers only
—At the DOS prompt, type
ifu list
and press
Enter
.
This command displays the ICP RAID controllers in your
system. Note the controller number for the controller you want
to update; you may need it in
to perform the update.
7
You can update the flash using any of the following
alternatives:
a
Updating the Flash on a Single Controller
—To flash the
firmware on a single controller, type:
ifu update /C <
controller_number
>
Where <
controller_number>
is the number of the controller
whose firmware you are updating. For example, to upgrade
controller 0, type:
ifu update /C 0