28
Hardware Installation and User’s Guide
Flash Memory Programming
Refer to
Section A.2
for help in deciding whether the firmware needs a recovery or
update.
Figure A-1. Jumper Positions for Flash Update and Recovery
Warning:
Shock hazards may be present inside the unit in which this controller is being
installed. Disconnect all power cords to the unit before removal of any covers.
Follow the warnings noted in your computer’s user or service manual before
installing this board. ONLY after all the covers are reinstalled should you reconnect
the power cords and power up the unit.
1. Take all precautions to prevent ESD damage before handling the ICP RAID controller.
2. Power off all system components and disconnect their power cords.
3. Remove the cover from the system to gain access to the PCI slots.
4. Remove the ICP RAID controller from your system.
5. On jumper block J4, move the jumper to position 1-2 for firmware recovery or to
position 2-3 for firmware updates. See
Figure A-1
and
Figure 2-3
for details.
6. Re-install the adapter in the PCI slot in which it was previously installed.
7. Replace the cover, reconnect all power cords and power up the system.
A.4
Updating or Recovering Firmware Using the FRUU
This section explains how to use the Firmware Recovery and Update Utility (FRUU) to
update or recover the firmware on the RAID controller. For help in choosing between
update and recover, see
Section A.2
.
Normal-Run /
Flash Update
Reset /
Flash Recovery
Jumper Block J4
3
2
1
3
2
1