"Rebuild" State
The disk array will assume this state after the automatic activation of a Hot Fix drive or after
a manual replacement carried out with ICPCON. The data and the redundant information
are reconstructed and stored to the new drive.
"Expand" State
If the capacity or RAID level of an existing disk array is changed, the disk array changes its
state into
expand
. As soon as the expansion or migration is completed, the state changes
back to
ready.
"Error" State
If a second hard disk should fail while the disk array is in the
fail
or
rebuild
state, it is not
possible to continue the working session without restrictions. The disk array is still avail-
able for I/Os, but data loss and error messages on the host level are possible.
The following state diagram of the disk array summarizes the states described above and
the transitions from one state to another.
Some of these states may become the addendum
patch
(e.g.
build/patch
,
ready/patch
).
This word indicates that the original Array Drive went through a significant procedure. I.e.,
the parity information was recalculated anew.
Or, the Array Drive has been patched from the error state into the fail state. This may be-
come extremely helpful in a situation where two Logical Drives of an Array Drive, fail at the
same time, but only one of the two Logical Drives is really defective and the other was
blocked out, since it was connected with the same SCSI channel as the defective one. The
Array Drive's state is error and normally all data would be lost. The ICP Controllers include
some functions, which allow the patch of this Array Drive from the error state into the fail
sate. Before the actual patch, the defective drive has to be physically removed from the Ar-
ray Drive. Such a patch-procedure is a real sheet-anchor and should only be used, after a
detailed consultation with a trained support person (a printout of the
Save Information
file, is
extremely helpful).
Pressing F4 delivers level by level detailed information on a Host Drive and its compo-
nents. This may assist to get an easy overview of a specific Host Drive. After pressing F5 the
ICP Controller switches the LEDs (if available) of the hard disks belonging to that Host
Drive on and off.
After selecting „Configure new Host Drive“, the ICP Controller scans all channels for free
hard disks (i.e., hard disks which are not yet part of a Host Drive) and displays these units
in a list. Use the Space bar to select/deselect hard disks and the cursor up down keys to
move the selection bar from one hard disk to another. Marked hard disks show an “*" in the
first column. In the choose Type windows all possible Host Drive types are displayed (the
possible types depend on the number of selected hard disks and the firmware level of the
ICP Controller).
Содержание GDT6618RD
Страница 2: ...2...
Страница 11: ...11 Chapter A General General General General Information Information Information Information...
Страница 21: ...21 8849 Wide Ultra2 Ultra 160 SCSI Bracket 8839 Wide Ultra2 Ultra 160 SCSI flat ribbon cable...
Страница 22: ...22 Typical Cluster Configuration 8844 8877 8880 SCSI Cable...
Страница 25: ...25 ICP Fibre Hub 1016 Rear View...
Страница 27: ...27 A 5 3 Sample Configurations Clustering with one FC AL ICP Fibre Hub 1016 configured as one Hub with 16 ports...
Страница 29: ...29 Chapter B I I I In n n nstallation Notes stallation Notes stallation Notes stallation Notes...
Страница 41: ...41 Chapter C ICP RAID Console ICP RAID Console ICP RAID Console ICP RAID Console ICPCON ICPCON ICPCON ICPCON...
Страница 73: ...73 Chapter D ICP RAID Navigator ICP RAID Navigator ICP RAID Navigator ICP RAID Navigator...
Страница 108: ...108...
Страница 109: ...109 Chapter E Appendix Appendix Appendix Appendix...