SERVICE AND TECHNICAL SUPPORT MANUAL

Gas Furnace: (F/G)9MVE

Specifications  subject to change without notice.

440 04 4801 04

11

Table 3 (cont.)

Orifice Size and Manifold Pressure (in. w.c.) for Gas Input Rate 

 Two

Stage

S

A

G

L

A

R

U

T

A

N

F

O

Y

T

I

V

A

R

G

C

I

F

I

C

E

P

S

S

A

G

.

G

V

A

HEAT VALUE

0.58

0.60

0.62

0.64

AT ALTITUDE

Orifice Mnfld Press Orifice Mnfld Press Orifice Mnfld Press Orifice Mnfld Press

(Btu/cu ft)

No.

High/Low

No.

High/Low

No.

High/Low

No.

High/Low

TWO-STAGE FURNACE

(TABULATED DATA BASED ON 20,000 BTUH HIGH-HEAT / 13,000 BTUH LOW-HEAT PER BURNER,

DERATED 2%/1000 FT (305M) ABOVE SEA LEVEL)

ALTITUDE

RANGE

ft (m)

650

42

3.4 / 1.4

42

3.5 / 1.5

42

3.6 / 1.5

42

3.7 / 1.6

7001

675

43

3.8 / 1.6

42

3.2 / 1.4

42

3.3 / 1.4

42

3.4 / 1.5

(2134)

700

43

3.5 / 1.5

43

3.7 / 1.5

43

3.8 / 1.6

42

3.2 / 1.4

725

44

3.8 / 1.6

43

3.4 / 1.4

43

3.5 / 1.5

43

3.6 / 1.5

750

44

3.5 / 1.5

44

3.7 / 1.5

44

3.8 / 1.6

43

3.4 / 1.4

8000

775

44

3.3 / 1.4

44

3.4 / 1.4

44

3.5 / 1.5

44

3.7 / 1.5

(2438)

800

45

3.8 / 1.6

44

3.2 / 1.4

44

3.3 / 1.4

44

3.4 / 1.4

825

46

3.7 / 1.6

46

3.8 / 1.6

45

3.8 / 1.6

44

3.2 / 1.4

625

42

3.4 / 1.4

42

3.5 / 1.5

42

3.6 / 1.5

42

3.7 / 1.6

8001

650

43

3.8 / 1.6

42

3.2 / 1.4

42

3.3 / 1.4

42

3.4 / 1.4

(2439)

675

43

3.5 / 1.5

43

3.6 / 1.5

43

3.7 / 1.6

42

3.2 / 1.3

700

44

3.7 / 1.6

43

3.4 / 1.4

43

3.5 / 1.5

43

3.6 / 1.5

725

44

3.5 / 1.5

44

3.6 / 1.5

44

3.7 / 1.6

44

3.8 / 1.6

9000

750

44

3.3 / 1.4

44

3.4 / 1.4

44

3.5 / 1.5

44

3.6 / 1.5

(2743)

775

45

3.7 / 1.6

44

3.2 / 1.3

44

3.3 / 1.4

44

3.4 / 1.4

9001

600

42

3.3 / 1.4

42

3.4 / 1.5

42

3.6 / 1.5

42

3.7 / 1.6

(2744)

625

43

3.7 / 1.6

42

3.2 / 1.3

42

3.3 / 1.4

42

3.4 / 1.4

650

43

3.5 / 1.5

43

3.6 / 1.5

43

3.7 / 1.6

43

3.8 / 1.6

675

44

3.7 / 1.6

44

3.8 / 1.6

43

3.4 / 1.4

43

3.5 / 1.5

10000

700

44

3.4 / 1.4

44

3.5 / 1.5

44

3.7 / 1.5

44

3.8 / 1.6

(3048)

725

44

3.2 / 1.3

44

3.3 / 1.4

44

3.4 / 1.4

44

3.5 / 1.5

* Orifice numbers shown in

BOLD

are factory-installed.

to

to

to

U.

S

.A.

On

ly

U.

S

.A.

On

ly

U.

S

.A.

On

ly

A11252B

Adjust Temperature Rise

NOTE

:  Blower door must be installed when taking temperature

rise reading. Leaving blower door off will result in incorrect
temperature measurements, due to possible changes in duct

static pressure and airflow.

FURNACE DAMAGE HAZARD

Failure to follow this caution may result in:

S

Overheating the heat exchangers or condensing

flue gases in heat exchanger areas not designed

for condensate.

S

Shortened furnace life.

S

Component damage.

Temperature rise must be within limits specified on furnace

rating plate. Recommended operation is at midpoint of rise

range or slightly above.

CAUTION

!

Furnace must operate within ranges of temperature rise

specified on the furnace rating plate.
When setup switch SW1

4 is ON, operation will be near the

high end of the rise range for improved comfort.
Determine air temperature rise as follows:

1. Place thermometers in return and supply ducts as near

furnace as possible. Be sure thermometers do not see

heat exchanger so that radiant heat does not affect

readings. This practice is particularly important with

straight

run ducts.

2. When thermometer readings stabilize, subtract return

air

temperature from supply

air temperature to determine air

temperature rise.

NOTE

:  Temperature rise can be determined for low

heat

operation by locking the furnace in each mode of operation.

The mode of operation is based on the position of set up switch
SW1

2 on the furnace control board.

This furnace is capable of automatically providing proper

airflow to maintain the temperature rise within the range

specified on furnace rating plate. If temperature rise is outside

this range, proceed as follows:

a. Check gas input for low

 and high

heat operation.

b. Check derate for altitude if applicable.

c. Check all return and supply ducts for excessive

restrictions causing static pressure greater than

0.5

in. w.c.

d. Ensure Low Heat Rise Adjust switch SW1

3 on

furnace control is in ON position when a bypass

humidifier is used. (See

 Figure 4

 for switch location.)

e. Check Troubleshooting Guide for Variable

Speed

Condensing Furnaces.

To lock the furnace in Low Heat:

1. Turn SW1-2 ON at the furnace control. Set up switch
2. Connect a jumper across R and W/W1 at the thermostat

terminals at the furnace control.

3. Allow the burners to ignite and the blower to turn on.
4. Allow the supply temperature to stabilize and verify the

proper rise range.

If the temperature rise is too high or too low in Low Heat:

Содержание F9MVE Series

Страница 1: ...abels The signal word WARNING is used throughout this manual in the following manner Safety alert symbol When you see this symbol on the unit and in instructions or manuals be alert to the potential f...

Страница 2: ...l result in enhanced installation reliability or operation FIRE EXPLOSION ELECTRICAL SHOCK AND CARBON MONOXIDE POISONING HAZARD Failure to follow this warning could result in dangerous operation perso...

Страница 3: ...in Connected Condensate Drain Trapped Manual Gas Shut off Upstream of Furnace Drip Leg Gas Valve turned ON Type of Gas Natural Propane Filter Type and Size Shade in Final Furnace Settings Below O N O...

Страница 4: ...l Setup Switches SW1 The furnace control has 8 setup switches that may be set to meet the application requirements To set these setup switches for the appropriate requirement 1 Remove blower door 2 Lo...

Страница 5: ...soap solution made specifically for the detection of leaks to check all connections A fire or explosion may result causing property damage personal injury or loss of life WARNING Adjustments FIRE HAZ...

Страница 6: ...0 Btu cu ft Specific gravity 0 62 Therefore Orifice No 44 Furnace is shipped with No 44 orifices In this example all main burner orifices are the correct size and do not need to be changed to obtain p...

Страница 7: ...ease input rate Figure 3 Redundant Automatic Gas Control Valve 2 Stage without Tower Pressure Ports ON OFF Switch Regulator Seal Cap RegulatorAdjustment Regulator Seal Cap under Cap 1 2 NPT Outlet 1 8...

Страница 8: ...s warning could result in personal injury death and or property damage Manifold pressure tap set screw must be tightened or 1 8 in NPT pipe plug must be installed to prevent gas leaks WARNING c Tighte...

Страница 9: ...300 21 171 343 857 62 58 116 290 22 164 327 818 64 56 112 281 23 157 313 783 66 54 109 273 24 150 300 750 68 53 106 265 25 144 288 720 70 51 103 257 26 138 277 692 72 50 100 250 27 133 267 667 74 48...

Страница 10: ...43 3 8 1 6 42 3 2 1 4 850 44 3 8 1 6 43 3 5 1 5 43 3 6 1 5 43 3 7 1 6 875 44 3 6 1 5 44 3 7 1 6 43 3 4 1 4 43 3 5 1 5 4000 900 44 3 4 1 4 44 3 5 1 5 44 3 7 1 5 44 3 8 1 6 1219 925 44 3 2 1 4 44 3 4 1...

Страница 11: ...re and airflow FURNACE DAMAGE HAZARD Failure to follow this caution may result in S Overheating the heat exchangers or condensing flue gases in heat exchanger areas not designed for condensate S Short...

Страница 12: ...r off delay See Table 4 and Figure 4 Figure 5 Table 4 Blower Speed Taps DESIRED HEATING MODE BLOWER OFF DELAY SEC SETUP SWITCH SW1 7 and 8 POSITION 90 OFF OFF 120 ON OFF 150 OFF ON 180 ON ON Adjust Co...

Страница 13: ...r refer to unit wiring diagram TWN 1 CFM 2 3 4 5 6 7 8 SW2 CF AC SW2 1 Twining OFF Allows for selection of furnace Main OFF or Secondary ON when Twinned furnace setup is required See kit instructions...

Страница 14: ...can be established that limit is functioning properly and will operate if there is a restricted return air supply or motor failure If limit control does not function during this test cause must be de...

Страница 15: ...FF OFF ON 605 565 510 455 420 See note 4 OFF ON OFF 785 750 705 675 630 585 See note 4 OFF ON ON 955 920 895 860 825 785 755 720 685 650 ON OFF OFF 1135 1110 1080 1055 1020 990 935 880 825 745 ON OFF...

Страница 16: ...0 22 Clg Default OFF OFF OFF 2010 1960 1910 1850 1800 1750 1690 1645 1565 1480 Cooling SW2 OFF OFF ON 1015 805 645 550 480 See note 4 OFF ON OFF 1075 975 915 835 765 See note 4 OFF ON ON 1205 1135 105...

Страница 17: ...itioned air is discharged upward Since this furnace can be installed in any of the 4 positions shown in Figure 7 you must revise your orientation to component location accordingly Figure 7 Multipoise...

Страница 18: ...isconnecting the limit switch To retrieve Status Codes follow the procedure below 2 Turn Setup Switch SW1 1 ON 3 Manually close blower door switch 4 Control will flash up to 7 Status Codes 5 The last...

Страница 19: ...eason Service as necessary 4 Inspect burner compartment before each heating season for rust corrosion soot or excessive dust If necessary have furnace and burner serviced by a qualified service agency...

Страница 20: ...balance will be affected 7 If greasy residue is present on blower wheel remove wheel from the blower housing and wash it with an appropriate degreaser To remove wheel a Mark blower wheel location on s...

Страница 21: ...following items must be performed by a qualified service technician If the burners develop an accumulation of light dirt or dust they may be cleaned by using the following procedure NOTE Use a back up...

Страница 22: ...the Hot Surface Igniter NOTE Use propane resistant pipe dope to prevent leaks Do not use Teflon tape 13 Install the gas pipe to the gas valve Figure 12 Igniter Position Side View L12F041 2 in 2 5 mm...

Страница 23: ...quired Verify a condensate trap gasket is included in the service kit or obtain one from your local distributor 1 Disconnect power at external disconnect fuse or circuit breaker 2 Turn off gas at exte...

Страница 24: ...wiring diagram and reconnect wires to flame rollout switch gas valve igniter and flame sensor 10 Turn on gas and electrical supplies to furnace 11 Check furnace operation through two complete heat op...

Страница 25: ...uart of anti freeze solution into the funnel tube Antifreeze should run through the collector box overfill condensate trap and flow to an open drain 8 Replace the rubber plug in the port on the collec...

Страница 26: ...SERVICE AND TECHNICAL SUPPORT MANUAL Gas Furnace F G 9MVE Specifications subject to change without notice 440 04 4801 04 26 Figure 15 Service Label 340688 2 REV D...

Страница 27: ...SERVICE AND TECHNICAL SUPPORT MANUAL Gas Furnace F G 9MVE Specifications subject to change without notice 27 440 04 4801 04 Figure 16 Wiring Diagram 340688 2 REV D...

Страница 28: ...t flashes When done put setup switch SW1 1 in the OFF position Was there a previous status code other than the heartbeat Go to section below for the status code that was flashed Does the control respo...

Страница 29: ...t check manifold pressure If OK check burner carryover and flame sensor location Clean flame sensor with fine steel wool and recheck current Nominal current is 4 0 to 6 0 microamps Is current near typ...

Страница 30: ...t high speed and the high heat pressure switch relay HPSR is de energized to close the NC contact When sufficient pressure is available the high heat pressure switch HPS closes and the high heat gas v...

Страница 31: ...tor BLWM will continue operating at cooling airflow for an additional 90 seconds Jumper Y Y2 to DHUM to reduce the cooling off delay to 5 seconds See Figure 4 b Two Stage Thermostat and Two Speed Cool...

Страница 32: ...eat pump the furnace control automatically changes the timing sequence to avoid long blower off times during demand defrost cycles Whenever W W1 is energized along with Y1 or Y Y2 the furnace control...

Страница 33: ...801 04 Figure 20 Variable Speed Furnace with Single Stage Heat Pump Dual Fuel L09F026 NOTE 9 Figure 21 Variable Speed Furnace with Two Stage Heat Pump Dual Fuel L09F028 NOTE 9 Figure 22 Variable Speed...

Страница 34: ...stallation Instructions for additional information and setup procedure 4 When using a Humidity Sensing Thermostat set DEHUMIDIFY OPTIONS to H DE ENRGZD FOR DEHUM 5 Optional connection If wire is conne...

Страница 35: ...ector box Condensate trap Condensate trap elbow Gaskets WARNING FIRE EXPLOSION ELECTRICAL SHOCK AND CARBON MONOXIDE POISONING HAZARD Failure to follow this warning could result in dangerous operation...

Страница 36: ...ed X ECM S Single stage T Two stage FEATURE B Base AFUE Efficiency E Extra AFUE Efficiency C Communicating D Dual Certified 2 pipe or 1 pipe R 2 pipe only S Single stage T Two stage N Standard L Low N...

Отзывы: