PRODUCT SPECIFICATIONS (Cont.)
Model
DLF4AH36K1A
Power
Supply
Rated Voltage
V
~
208/230
Rated Frequency
Hz
60
Phases
1
Power Supply Mode
Outdoor
Cooling Capacity (Min
−
Max)
Btu/h
33600 (7400
−
36000)
Heating Capacity (Min.
−
Max)
Btu/h
N/A
Cooling Power Input (Min.
−
Max.)
W
3650 (410
−
3800)
Heating Power Input (Min.
−
Max.)
W
N/A
Cooling Current Input
A
15.9
Heating Current Input
A
N/A
Rated Input
W
4200
Rated Current
A
18.2
Air Flow Volume (S/H/M/L)
CFM
−
/824/706/677/
−
Dehumidifying Volume
Pint/h
1.66
EER
Btu/hW
9.21
COP
Btu/hW
N/A
SEER
16
HSPF
N/A
Application Area
m
2
495
−
753
Model
−
Indoor Unit
DLF4AH36K1A
Indoor Unit
Fan Type
Cross
−
flow
Fan Diameter Length (DXL)
inch
f
4.25x20.58X2
Cooling Speed (SH/H/ML/SL)
r/min
−
/1550/1400/12300/
−
Heating Speed (SH/H/ML/SL)
r/min
N/A
Fan Motor Power Output
W
60
Fan Motor RLA
A
0.47
Fan Motor Capacitor
m
F
3.5
Input of Heater
W
N/A
Evaporator Form
W
Aluminum Fin
−
Copper Tube
Evaporator Pipe Diameter
inch
f
11/40
Evaporator Row
−
fin Gap
inch
2
−
0.055
Evaporator Coil Length (LxDxW)
inch
142.3x1x15
Swing Motor Model
MP24BA
Swing Motor Power Output
W
2
Fuse Current
A
3.15
Sound Pressure Level
(SH/H/M/L/SL)
dB (A)
−
/59/56/53/
−
Sound Power Level
(SH/H/M/L/SL)
dB (A)
−
/69/66/63/
−
Dimension (WxHxD)
inch
53.1X12.8X10.0
Dimension of Carton Box
(WxHxD)
inch
56.6X16.5X13.5
Dimension of Package (WxHxD)
inch
56.7X16.6X14.0
Net Weight
lb
44.1
Gross Weight
lb
59.5