VXC-112(i)(A)U/142(i)AU/182i(A)U/114(iA)U/144(i)U, VEX-114(i)/144(i) , VEX-112(i)/142(i) User’s Manual (Ver. 1.5
Aug.10 2012) -----54
4.4 Programmable Baud Rate
Baud Rates Using a 14.7456 MHz Crystal
(Universal series cards)
DESIRED
BAUD RATE
DIVISOR USED TO
GENERATE 16× CLOCK
PERCENT (%) ERROR
50
18432
75
12288
110
8376
0.026
150
6144
300
3072
600
1536
1200
768
2400
384
4800
192
9600
96
14400
64
19200
48
23040
40
28800
32
38400
24
56000
16
2.86
57600
16
115200
8
184320
5
230400
4
307200
3
460800
2
Warning: