background image

ICP DAS Co., LTD 

PM-3033 series Quick Start V1.10 

Page 1 

PM-3033 series Quick Start 

 

1. 

Shipping Package 

This shipping package contains the following items 

 
1 x PM-3033 module      1 x Quick Start             Screw Driver x 1          CD x 1 

  (This Document)       

 

 

2. 

PM-3033

 series 

introduction 

ICP DAS brings the most powerful, cost-effective, advanced Smart Power Meters PM-3033 series that 

gives you access to real-time electric usage for three-phase power measurement. With its high accuracy 
(<0.5%, PF=1 ), the PM-3033 series can be applied to both low voltage primary side and/or medium/high 
voltage secondary side and enables the users to obtain reliable and accurate energy consumption readings 
from the monitored equipments in real time under operation. 
Direct input from “secondary side 1A/5A” type CTs. Dedicated CTs are no longer needed, which lowers the 
cost of implementation. 
It operates over a wide input voltages range 10 ~ 500 VAC which allows worldwide compatibility. It also 
supports Modbus RTU, Modbus TCP or CANopen protocols for easy integration. 

 

2.1.  Caution & Warning 

The meter contains hazardous voltages, and should never be disassembled. Failing to follow 

this practice will result in serious injury or death. Any work on or near energized meters, 

meter sockets, or other metering equipment could induce a danger of electrical shock. It is 

strongly recommended that all work should be performed only by qualified industrial 

electricians and metering specialist. ICP DAS assumes no responsibility if your electrical installer does not follow 

the appropriate national and local electrical codes. 

ICP DAS assumes no liability for any damage resulting from the use of this product. ICP DAS reserves the right to 

change this manual at any time without notice. The information furnished by ICP DAS is believed to be accurate 

and reliable. However, no responsibility is assumed by ICP DAS for its use, not for any infringements of patents or 

other rights of third parties resulting from its use. 

2.2.  Product Warranty & Customer Support 

ICP DAS warrants all products free from defects in material and workmanship for a period of one year from the 

date of shipping. During the warranty period, we will, at our position, either repair or replace

 

any product that 

proves to be defective. To report any defect, please contact 

+886-3-

 

597-3366

 or 

[email protected]

.   

2.2.1.  Limitation of Warranty 

This warranty does not apply to defects resulting from unauthorized modification, misuse, or use for reason other 

than electrical power monitoring. The supplied meter is not a user-serviceable product. 

Содержание PM-3033 Series

Страница 1: ...y or death Any work on or near energized meters meter sockets or other metering equipment could induce a danger of electrical shock It is strongly recommended that all work should be performed only by...

Страница 2: ...hase sequence of the power system PM 3033 series can be installed as rail mounting mode or embedded no need to drill a hole or screw to fix it rail mounting width can up to the length of 35 mm Meter a...

Страница 3: ...the arrow direction sign on Primary CT s follows current flow direction K L Note it must be in the same direction Connect the voltage input terminal N C B A for PM 3033 series in the three phase orde...

Страница 4: ...ICP DAS Co LTD PM 3033 series Quick Start V1 10 Page 4 Wiring 1P2W 1CT PM 3033 series 1P3W 2CT PM 3033 series 3P3W 2CT PM 3033 series...

Страница 5: ...ED will flash when the unit is processing communication PWR Red Power on LED always on 3 Communication RS 485 CAN setting Default setting for RS 485 19200 n 8 1 for CAN 125K bps DIP switch SW1 SW6 is...

Страница 6: ...OFF 20 ON ON OFF OFF ON OFF 21 OFF OFF ON OFF ON OFF 22 ON OFF ON OFF ON OFF 23 OFF ON ON OFF ON OFF 24 ON ON ON OFF ON OFF 25 OFF OFF OFF ON ON OFF 26 ON OFF OFF ON ON OFF 27 OFF ON OFF ON ON OFF 28...

Страница 7: ...bps 500k bps OFF ON 115200 bps 1M bps ON ON PM 3033 series Select the different wiring mode Please select the Software setting if 1P2W 1CT or 1P3W 2CT is used Models PM 3033 PM 3033 CPS PM 3033 MTCP W...

Страница 8: ...Reactive Energy kVARh Power Factor PF Frequency Hz Data Update Rate 1 Second Communication RS 485 Protocol Modbus RTU Baud rate 9600 19200 default 38400 115200 DIP Switch Selectable Data format N 8 1...