PISO-DNM100 DeviceNet Master API functions User’s Manual (Ver: 1.0) 2008/02/25
117
4.4.56 DNM100_WriteCOSOutputData
z
D
escription:
This function is used to set the data according with the consumed
connection path of the specific slave device via the COS connection.
z
Syntax:
DWORD DNM100_WriteCOSOutputData (BYTE BoardNo,
BYTE DesMACID,
WORD IOLen,
BYTE *IODATA)
z
Parameter:
BoardNo:
[input] PISO-DNM100 board number (0~15)
DestMACID:
[input] The remote slave device’s MAC ID (0~63)
IOLen:
[input] The length of the I/O data (In byte).
IODATA:
[input] The remote I/O data which are defined by users.
z
Return:
DNM100_NoError (0):
OK
DNM100_DriverError (10001):
Kernel driver is not opened.
DNM100_ActiveBoardError (10002):
This board can not be activated or
kernel driver can not be found.
DNM100_BoardNumberError (10003):
BoardNo exceeds the current
scanned total board number.
DNM100_TimeOut (10023):
The PISO-DNM100 has no response.
Others:
Please refer to Table 4.2.2 ~ Table 4.2.9