4.

 

Wire the signal source to channel 0, and then keep set the JP1 jumper to 

Single-Ended

 

(page 3)

, and wire the signals as follows: 

 

Connect the 

AI 0 (Pin01)

 to 

signal positive (+)

 

Connect the 

A.GND (Pin17) 

to 

signal negative (-)

 

 
 
 
 
 
 
 
 
 
 
 

5.

 

Execute the UniDAQ Utility Program.

 

 
This program (UniDAQ Utility) will be placed in the default path after completing installation.

 

The UniDAQ Utility.exe is located in (Default path): C:\ICPDAS\UniDAQ\Driver\   
 
 

Click  this  button 
to start test. 

Confirm the PCI-1002 series card 
had successfully installed to PC. It 
starts from 0. 

Double-Click   

Содержание PCI-1002 LU

Страница 1: ...Utility CD V5 2 or later One Quick Start Guide This Document One CA 4002 D Sub connector Step 1 Setup the Windows driver The driver is located at The UniDAQ driver supports 32 64 bit Windows 2K XP 200...

Страница 2: ...on Step 4 Select the installed folder the default path is C ICPDAS UniDAQ confirm and click the Next button Step 5 Check your DAQ Card on list then click the Next button Step 6 Click the Next button o...

Страница 3: ...Setting Card ID 1 ID0 2 ID1 3 ID2 4 ID3 0 ON ON ON ON 1 OFF ON ON ON 2 ON OFF ON ON 0xD OFF ON OFF OFF 0xE ON OFF OFF OFF 0xF OFF OFF OFF OFF Step 1 Shut down and power off your computer Step 2 Remov...

Страница 4: ...PCI 1002 PEX 1002 L H Series Quick Start Guide ICP DAS CO LTD 4 WebSite http www icpdas com tw E Mail service icpdas com service icpdas gmail com Pin Assignments...

Страница 5: ...pdas com service icpdas gmail com DIO Test Wiring 1 Use CA 2002 optional to connect the CON1 with CON2 Analog Input Test Wiring 2 Prepare for device DN 37 optional Wiring terminal board Provide a stab...

Страница 6: ...e the signals as follows Connect the AI 0 Pin01 to signal positive Connect the A GND Pin17 to signal negative 5 Execute the UniDAQ Utility Program This program UniDAQ Utility will be placed in the def...

Страница 7: ...as com tw E Mail service icpdas com service icpdas gmail com 6 Get DIO function test result Select the Port 0 8 The corresponding D I becomes red for channel 0 2 4 6 of D O is ON 9 Click Digital Input...

Страница 8: ...002 html DN 37 CA 3710 and CA 2002 page optional http www icpdas com products DAQ screw_terminal dn_37 htm http www icpdas com products Accessories cable cable_selection htm Documentation and Software...

Отзывы: