(A)
Open ‘
Hyper Terminal
’ on the Host PC to monitor the test process. The default settings
for COM3 port are 9600, 8, N, 1
(B)
Send data via /dev/ttyS1 port:
On the LP-8x21:
Type the command:
echo send-232 >/dev/ttyS1
Check that the word ‘send-232’ is displayed on the ‘Hyper Terminal’ screen on the PC
(C)
Receive data via the /dev/ttyS1 port:
On the LP-8x21:
Type the command:
cat /dev/ttyS1
On the PC:
Enter some text in the ‘Hyper Terminal’ screen on the PC
Check that the some words on the LP-8x21.
LP-8000 send information via COM3 port
Receive data from COM1 port of PC
Receive data via the COM3 port
Send information via COM1 port of PC
Figure 2.7.5.2-4.
Using the command line to test