background image

 

I-7014D AI DAQ Module - QuickStart (Jan/2017)  

ICP DAS USA, Inc.

 | 

www.icpdas-usa.com

 | 1-310-517-9888 | 24309 Narbonne Ave. Suite 200. Lomita, CA 90717

 

 

 

4. Open DCON utility pro

 

click on COM port(first icon).  

It can select multi-options such as Baud Rate, Protocol, Checksum, and Format to 

search module. The default settings for the module can be found in Section 3. Click OK 
after selecting the COM port setting. 
 

 

 
 
 
 
 
 
 
 
 

Содержание I-7014D

Страница 1: ...onditioning system monitoring alarm signal output and safe value settings I 7014D is a cost effective solution for a wide range of valuable industrial control signals and systems The DCON utility can help users to configure and test I 7014D Analog Transmitter input modules Plenty of library functions and demo programs are provided to let users develop programs easily under Windows Linux and DOS op...

Страница 2: ...I 7014D AI DAQ Module QuickStart Jan 2017 ICP DAS USA Inc www icpdas usa com 1 310 517 9888 24309 Narbonne Ave Suite 200 Lomita CA 90717 2 3 Block Wiring Diagram ...

Страница 3: ...neer unit format z I 7017 17F set as 6 differential and 2 single ended mode z I 7012F and I 7017F set as Fast Mode 5 Configuration To install the module follow the steps below 1 Connect the analog output 2 Connect the module to the RS 485 network using the DATA and DATA terminals If the host is only equipped with an RS 232 interface then an RS 232 to RS 485 converter will be required 3 Connect the...

Страница 4: ...09 Narbonne Ave Suite 200 Lomita CA 90717 4 4 Open DCON utility pro click on COM port first icon It can select multi options such as Baud Rate Protocol Checksum and Format to search module The default settings for the module can be found in Section 3 Click OK after selecting the COM port setting ...

Страница 5: ...10 517 9888 24309 Narbonne Ave Suite 200 Lomita CA 90717 5 5 DCON utility pro will search for the selected COM port according the setting previously set DCON Utility Pro supports DCON and Modbus protocol for all ICPDAS and the others modules 6 Configuration I O module setting on PC ...

Страница 6: ...200 Lomita CA 90717 6 7 For I 7000 modules DCON utility pro terminal can send command to the module See user manual Sections 2 for details command Configure the module sending the AANNTTCCFF command See user manual Section 2 for details Read data from the input channels send either the AA or AAN command to the module ...

Страница 7: ...USA Inc www icpdas usa com 1 310 517 9888 24309 Narbonne Ave Suite 200 Lomita CA 90717 7 8 If user doesn t know command user can select Address and ID it will show some refer commands as below User can select necessary command to test or debug modules ...

Отзывы: