Byte 6: Net ID (Station number)
Byte 7: FC=06 (Hex)
Byte 8-9: Reference number
Byte 10-11: Register value
Example: Start sending J1939 output message
In the address
42009
, write the value in 0x00.
[Request Command] (Byte0, Byte1... Byten) (Hex)
00 00 00 00 00 06
01 06 07 D8 00
00
GW-7238D responds the register value.
[Response] (Byte0, Byte1... Byten) (Hex)
00 00 00 00 00 06
01 06 07 D8 00
00
Example: Stop sending J1939 output message
In the address
42009
, write the value in 0x01.
[Request Command] (Byte0, Byte1... Byten) (Hex)
00 00 00 00 00 06
01 06 07 D8 00
01
GW-7238D responds the register value.
[Response] (Byte0, Byte1... Byten) (Hex)
00 00 00 00 00 06
01 06 07 D8 00
01
Or
Without have to control the Modbus register 42009 (Dec), just enable
Auto transmission function in J1939 configuration area as below, and
upload to GW-7238D.
Figure 5-14: J1939 Auto Transmission function screen