iCool Compact Series  |  Owners Manual

07

 

24/7 operation is acceptable, electronically controlled to provide lowest possible running cost

 

Recommended temp for ice bath recovery : 8 -10ºC (46-50ºF) is recommended by most sports science experts.

4. 

Requirements of the room

 

The area of the room where the Mipod is installed should not be less than 6 Sq Meters (65Sq Ft)  for best results

 

The door frames should be at least 780mm wide (32 inches) to allow the Mipod to be easily carried inside. 

 

Airflow: Models with internal chillers must be at least 300mm from all walls to allow proper ventilation and airflow   

 

for the refrigeration system to remove the heat from the water.  Read more on Safety issues section 7.

 

We recommend having good  ventilated  in to the room or to use air conditioning. 

 

A 3 pin grounded power outlet is absolutely mandatory for user safety. Never use a 2 pin plug it could be dangerous.

 

Your MiPod is fitted with an electrical safety device to protect users,  but it must have an earthed power socket.

 

Avoid the use of long extension cords as they result in voltage drops that may trigger the inbuilt safety system.

 

Ambient room temperature around  all models with inbuilt chillers should be 10-25ºC for best results.(50-77F) 

 

(5º to 40º  (40-104F) is the Maximum operating range allowed. 

 

If you experience  very cold weather, do allow the pool water to freeze or serious damage could occur. 

 

If freezing conditions are expected in the room where the MiPod is installed , empty the water or turn on the            

 

heating if your model has that function to keep the water above freezing.Also do not allow external chillers  

 

 

to freeze. If you have an external chiller empty the water from it if severe freezing weather is expected. 

5. 

Basic Set up

Level Surface: The surface should be flat, level, with no inclination if possible. 

If surface is not level then suitable packing will be required under the Mipod to ensure that water is level.

Once the Mipod is filled with water, it will be too heavy to move so make sure it is correctly positioned and level. 

Essential Ventilation: The large rear vent and both side vents must be at least 300mm (1 foot) from all walls or obstruction to 

allow enough cooling airflow to the refrigeration sytem or it may overheat and cause the safety system to shut it down.

Your MiPod has many safety features built in, it will stop if it has no water, or if it is too hot. The screen will show the problem.

Connect the blue data cable from the screen to the MiPod and the power cable to a standard power outlet first. If you have an 

external chiller then the plumbing pipes between it and the MiPod and the external chiller must be connected as well. 

For models with built in refrigeration units....

..

a) 

Connect the power cable to a 3 pin earthed wall socket rated at least 12 amps at 220 volts  (25amps at 110volts)

b) 

Plug in the provided data cable to the socket located under the rear of the touch screen

c) 

Mount the screen on a wall or where required and Swtich ON the wall power outlet supplying the MiPod. 

d) 

Check that the screen is working , a welcome page will appear on the touch screen.

If the screen does not light up, please make sure that:

 

The MiPod power cable is lugged into a wall socket directly, do not use long extension cables.

 

Check that the electrical safety device (RCD) is switched on – this is inside the MiPod and is normally turned on at 

the factory, but if the screen does not light up you should check that it is actually ON. You will need to open the small air vent 

on the right side vent (on the right when standing in front of the large black vent on the back)   Look inside and up to the 

left and you will see the narrow main power panel with a safety device at the top of the panel. It has a large black switch and 

an orange button. The black switch must be in the UP position. Please be aware that if your MiPod ever detects a potential 

electrical safety risk this switch will instantly turn off all electric power to your MiPod.  Always have an electrician inspect your 

MiPod for safety should this ever happen and before turning it back on.  

While the vent is open also check that the Blue data cable is well connected to the bottom of the narrow electrical panel.

Содержание iCool MiPod Series

Страница 1: ...Page iCool Compact Series Owners Manual 01 iCool 2021 MIPOD Series Owners Manual icoolsport com info icoolsport com...

Страница 2: ...Page iCool Compact Series Owners Manual 02...

Страница 3: ...System Settings Starting Up Heat Mode Product use Requirements How to Use Page 05 Page 09 Page 12 Page 11 Page 06 Page 08 Index Starting Up Chill Mode Page 10 Session Timer Page 13 01 03 05 07 Trouble...

Страница 4: ...04 MiPod Pro UPDATED PICTURE NEEDED HERE...

Страница 5: ...g cost of around 30 50c a day is all it uses to keep your water at your desired ice bath or recovery temperature ready for use anytime day or night whenever you need it No waiting This revolutionary n...

Страница 6: ...nal steps and fully enclosed An alternative version is also available for the pool to be connected to a remote chiller heater that can be placed in any convenient place nearby This version is ideal wh...

Страница 7: ...sure it is correctly positioned and level Essential Ventilation The large rear vent and both side vents must be at least 300mm 1 foot from all walls or obstruction to allow enough cooling airflow to t...

Страница 8: ...ater Fill pool with water but allow enough space above the water to handle the water displacement and prevent overflow when users enter the pool This is particularly important if you intend to have 2...

Страница 9: ...If this happens then after a short time a small blue square appears at the top left of the screen as shown below Simply tap anywhere on this small blue square to connect manually Do not touch anything...

Страница 10: ...ART Button The system s computer takes over and enters the fully automatic mode It will now operate the chiller to achieve your selected temperature and when it is reached it will hold it accurately f...

Страница 11: ...ible with the DT Dual Temp or heat only models Continuous Always Available Operation Your MiCool has been manufactured using quality components from the world s leading manufacturers and is therefore...

Страница 12: ...achine choose SETTINGS from the list You can change between Centigrade and Fahrenheit You can select the volume of the System Sounds You can change the appearance from Dark Mode to Light Mode You can...

Страница 13: ...ON TIMER This allows you to pre set the amount of time athletes should remain in the pool It provides a count down on the screen It sounds a warning at the end of the session It can automatically re s...

Страница 14: ...er several attempts it can not correct the lack of water flow it will shut the machine down and warn you that action must be taken to correct it Water Flow Alarm Your MiPod will attempt to correct any...

Страница 15: ...ar if the MiPod is unable to correct the water flow Problem in Itself In this case you must take further action to correct the problem If it can fix the water flow automatically then this message will...

Страница 16: ...rge main fan may continue to run for some time even after a shut down until the temperature is safely back to normal For the safety of users any leakage of even a small amount of electrical current wi...

Страница 17: ...more than 45 C eventually the system will reach the limit of its safe operating range If the temperature inside the cabinet reaches 68 C the safety system will shut it down sound an alarm and display...

Страница 18: ...feet of air per minute Air flow must never be blocked by any object On very hot days when the air temperature is more than 45 C it may not be possible to run the system at full power due to the exces...

Страница 19: ...Page 19 iCool Compact Series Owners Manual...

Страница 20: ...es Yes Yes Hi Resolution LCD Colour Touch Screen 13 Inch High Definition 13 Inch High Definition 13 Inch High Definition 13 Inch High Definition 10 Inch High Definition Electrically Isolated Pump Supp...

Страница 21: ...eedback and suggestions and we offer support for general inquiries and information for specific countries on our website at icoolsport com Notes About Specifications Thank You For Choosing iCool The W...

Страница 22: ...r printed on the Rating Label affixed to the machine Retailer Country and Name Date of Purchase and Proof of Purchase required Warranty Justemailusatinfo icoolsport com and we will respond with assist...

Страница 23: ...Page 23 iCool Compact Series Owners Manual The industry leader in ice bath technology...

Страница 24: ...Page 24 iCool Compact Series Owners Manual info icoolsport com 61 428 944 741 BurleighHeads GoldCoast Australia Representatives around the world icoolsport com...

Отзывы: