background image

S.T.INNOVATORS

 

ICON rev.may 2010

 

4

IMPORTANT SAFETY INSTRUCTIONS! 

 

PLEASE READ THEM BEFORE OPERATING THIS EQUIPMENT. 

 

The lightning flash with arrowhead, 
within an equilateral triangle, is intended 
to alert the user to the presence of 
uninsulated "dangerous voltage" within 
the product's enclosure that may be of 
sufficient magnitude to constitute a risk 
of electric shock to persons.

 

 

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN 

AVIS 

RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR.

 

 
 
 

The exclamation point within an equi-
lateral triangle is intended to alert the 
user to the presence of important 
operating and maintenance (servic-
ing) instructions in the literature ac-
companying the appliance.

 

WARNING - TO REDUCE RISK OF

 

FIRE OR ELECTRICAL SHOCK, DO

 

NOT EXPOSE THIS EQUIPMENT TO

 

RAIN OR MOISTURE.

 

 

NO USER-SERVICEABLE PARTS

 

INSIDE. REFER SERVICING TO

 

QUALIFIED PERSONNEL.

 

To prevent the risk of electric shock, do not remove cover 

or back. No user serviceable parts inside.

 

 

General:

 

1. Read these instructions. 
2. Keep these instructions. 
3. Heed all warnings. 
4. Follow all instructions. 

5. Warning: To reduce risk of fire or electrical shock, do not expose this equipment to rain or moisture. This 
unit is capable of producing high sound pressure levels. Continued exposure to high sound pressure levels 
can cause permanent hearing impairment or loss. User caution is advised and ear protection is recommended 
when playing at high volumes. 
6. Caution: to prevent electrical shock do not use this (polarized) plug with an extension cord, receptacle or 
other outlet unless the blades can be fully inserted to prevent blade exposure. 
Attention: pour pevenir les chocs elecriques pas utiliser cette fiche polarisee avec un prolongateur, une prise 
de courant ou un autre sortie de courant, sauf si les lames peuvent etre inserees afond ans en laisser aucune 
partie a decouvert. 

7. Unplug this equipment during lightning storms or when unused for long periods of time. 
8. Only use attachments/accessories specified by the manufacturer. 

 
Installation:

 

9. The equipment shall be installed near the AC Socket Outlet and the disconnect device shall be easily accessible. 
10. Do not block any ventilation openings. Install in accordance with the manufacturer's instructions. 
11. Do not install near any heat sources such as radiators, heat registers, stoves, or other equipment (including 
amplifiers) that produce heat. 
12. Do not use this equipment near water. 
13. Do not expose this equipment to dripping or splashing and ensure that no objects filled with liquids, such as vases, 
are placed on the equipment.  

 

14. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the equipment. 
When a cart is used, use caution when moving the cart/equipment combination to avoid injury from tip-over. 
 

Connection:

 

15. Connect this equipment only to the type of AC power source as marked on the unit. 
16. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the 
point where they exit from the equipment. 
17. Do not defeat the safety purpose of the polarized or grounding-type plug. 
A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third 
grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into 
your outlet, consult an electrician for replacement of the obsolete outlet. 
18. Do not overload wall outlets, extension cords or integral convenience receptacles as this can result in a risk of fire 
or electric shock. 

Содержание STEREO TUBE POWER AMPLIFIER

Страница 1: ...STEREO TUBE POWER AMPLIFIER STEREO TUBE REAMPLIFIER USER S MANUAL S T I N N O V A T O R S S O F I A 1 5 0 5 1 T Z A R I C H I N A S T R T E L 8 7 0 2 1 5 6 F A X 9 7 3 3 7 2 7...

Страница 2: ...S T INNOVATORS ICON rev may 2010 2...

Страница 3: ...3 7 Tubes Connections and Switches location 14 8 How to Connect for Stereo 16 9 How to Operate the ICON 18 Power On Stand by and Off 18 Input Switch 18 10 Setting the Tubes Bias 19 11 Specifications 2...

Страница 4: ...arisee avec un prolongateur une prise de courant ou un autre sortie de courant sauf si les lames peuvent etre inserees afond ans en laisser aucune partie a decouvert 7 Unplug this equipment during lig...

Страница 5: ...pped 24 Do not attempt to service beyond that described in the operating instructions All other service should be referred to qualified service personnel 25 When replacement parts are required be sure...

Страница 6: ...S T INNOVATORS ICON rev may 2010 6 STEREO TUBE POWER AMPLIFIER...

Страница 7: ...r cables are 50 feet 38 1m or less use at least 14 Gauge If your loudspeaker cables are 100 feet 76 2m or less use at least 12 Gauge 5 Pin configuration for the XIR Balanced Input connectors on the IC...

Страница 8: ...may 2010 8 4 ICON Stereo Tube Power Amplifier Dimensions The following dimensions can assist in determining the best location for your ICON Front View of ICON Figure 1 Rear View of ICON Figure 2 Side...

Страница 9: ...hat is your case then follow the next steps Note Gloves or a soft cloth will prevent fingerprinting of the Tubes during their installation 1 Using an appropriate screwdriver remove screw from the bott...

Страница 10: ...S T INNOVATORS ICON rev may 2010 10 Figure 5 Tube Box GU50 V5L GU50 V4L GU50 V4R GU50 V5R GU19 1 V3L 6N1P EV V2L 6N1P VI V1L EM800 V6L EM800 V6R 6N1P VI V1R 6N1P EV V2R GU19 1 V3R...

Страница 11: ...of the Tubes during their installation Power Output Tubes 1 Orient the Chassis so that the Front Panel of the Amplifier is facing you 1 Locate a GU50 V5L Power Output Tube Refer to figure 6 2 On the...

Страница 12: ...e Small Input Tubes There are two different types of Small Input Tubes 6N1P EV and 6N1P VI used in each channel Tube type can be found on the outside of the Tube The ICON will not function if they are...

Страница 13: ...knob 6 Location and Ventilation The ICON can be placed upright on a table or shelf standing on its four feet Adequate ventilation extends the trouble free life of the ICON The suggested minimum space...

Страница 14: ...ion 1 3 5 2 4 6 7 9 11 8 10 12 13 Figure 9 1 3 GU50 output tubes for left channel 2 4 GU50 output tubes for right channel 5 6 GU19 1 driver tubes 7 8 6N1P EV input tubes 9 10 6N1P VI input tubes 11 12...

Страница 15: ...elects between the BALANCED or UNBALANCED INPUTS 8 9 RIGHT and LEFT outputs connections for loudspeakers 10 grounding connector 11 power synchronization connector with preamplifier 12 Input 12V trigge...

Страница 16: ...r or prepared section of the cable end into the terminal side access hole and tighten the terminal cap until the cable is firmly clamped into the terminal so the wires cannot slip out Banana plug conn...

Страница 17: ...S T INNOVATORS ICON rev may 2010 17 Connect to AC Outlet Connect to AC Outlet Figure 11 Stereo Connection...

Страница 18: ...uld be shut down when not being used This will greatly prolong tube life A standby mode has been provided for short term use between listening sessions so that the amp will remain in a warmed up state...

Страница 19: ...benefit to this approach is that should a tube fail prematurely the single tube can be replaced without having to purchase a matched set Use the following procedure to set the tube bias WARNING There...

Страница 20: ...ping Factor Greater than 8 Input Impedance 100 k unbalanced inputs 200 k balanced inputs Power Supply Impulse power supply 120 V from 100 to 135 V 50 60 Hz at 10 230 V from 195 to 260 V 50 60 Hz at 5...

Страница 21: ...n damage to the Vacuum Tubes and possibly the ICON It is very important that the four feet are attached to the bottom of the equipment This will ensure the proper equipment location on the bottom pad...

Страница 22: ...S T INNOVATORS ICON rev may 2010 22 STEREO TUBE PREAMPLIFIER...

Страница 23: ...uld not be applied until all the system components are connected together Failure to do so could result in malfunctioning of some or all of the system s normal operations 2 ICON Stereo Tube Preamplifi...

Страница 24: ...4 200 mm 232 mm 365 mm 475 mm 3 ICON Dimensions The following dimensions can assist in determining the best location for your ICON Front View of ICON Figure 1 Rear View of ICON Figure 2 Side View of I...

Страница 25: ...peration ensures the longest possible operating life for any electronic instrument Do not install the ICON Pre directly above a heat generating component such as a high powered amplifier If all the co...

Страница 26: ...t for AUX 5 Right and Left first output 6 Right and Left second output 7 GND terminals 8 Power synchronization connector with power amplifier 9 Output 12V trigger for remote power control 10 Power sup...

Страница 27: ...S T INNOVATORS ICON rev may 2010 27 7 How to Connect the ICON Preamplifier Connect to AC Outlet Connect to AC Outlet Figure 6...

Страница 28: ...ights to indicate the preamplifier is Switched Off The Blue LEDs inside the Power On and Source Selection Switch lights to indicate the preamplifier is connected to AC Power Select the desired source...

Страница 29: ...tilation extends the trouble free life of the ICON Pre The suggested minimum space for operating the ICON Pre is 70 cm in width 60 cm in depth and 60 cm in height Always allow air to flow through the...

Страница 30: ...io A Weighted High Level 90dB Phono 82dB Input Impedance High Level 24K ohms unbalanced Phono MM 47K ohms 120pF Adj 50 680pF Maximum Input Signal High Level 10V Unbalanced Phono MM 50mV Voltage Gain H...

Страница 31: ...the proper equipment location on the bottom pad Failure to do this will result in shipping damage Four M6x50 mm screws must be used to fasten the unit securely to the Shipping Skid Failure to do this...