Interference Problems 

The  amplifier  design  incorporates  features  and  devices 
which  make  it  resistant  to  mains-born  interference.  But 
some  CH  boilers/fridges/cookers  etc  can  generate  RF 
(radio  frequency)  interference  which  travels  through  the 
air  (and  walls).  Although  rare  this  can  be  very  irritating. 
Usually  a  simple  cure  by  fitting  a  capacitor  to  the 
offending unit will effect a cure (ask us). 

 

One channel missing. 

Usually  ‘bad’  connection  on  either  the  input  or  the 
speakers. Try swapping the connection over to establish 
if the cause is: 
(a) Input to the amp. 

Sound  will  move  to  the  other 

channel. 
(b) Amplifier or speakers. 

Sound will not move. 

Also see internal fuses above 

 

Strange noises coming from speakers: 
Turn  volume  to  minimum  on  unused  input,  if  problem 
corrected either fault with source unit or with connection. 
If noise persists, problem with amplifier. 

 

If a whole output valve glows red (other than the heater), 
often  accompanied  by  a  hum  through  the  speakers, 
switch  off  immediately,  and  refer  to  Icon  Audio  or  a 
service engineer, as this could be valve failure. 

 

A valve that is lit up is not a guarantee that it is working 
properly;  conversely  a  valve  that  is  not  lit  up  will  not  be 
working (usually cold to the touch). 

 

Valve Replacement 

(see also section 7) 

Valve  life  will  depend  upon  such  things  as  hours  of  use 
and  number  of  on/off  cycles,  Do  not  switch  on  and  off 
unnecessarily (see 

Standby).

 Also it is not good practice 

to remove the valves unnecessarily as this can strain the 
pins and cause tiny air leaks.  

 

Service: 

Should  you  suspect  a  problem,  you  could 

return  the  unit  to  Icon  Audio  for  a  periodic  service  or 
return  the  valves  for  testing  free  of  charge.  You  should 
carefully  remove  the  valves  (hold  the  base  when 
removing,  to  prevent  detaching  the  glass)  numbering 
them  with  a  marker  from  left  to  right  as  you  do  so  in 
order  that  that  may  be  replaced  in  the  same  position. 
They  should  be  well  packed  in  cardboard  &  foam  or 
similar,  and  returned  to  Icon  Audio  for  testing.  (Valves 
are very rugged if packed properly). 

 

Mains Supply 

This amplifier is hard wired to work on 230/240v ac. The 
transformer may easily be re-configured for 110/120v ac. 
Contact us for more information. 

 

 

6. Bias Checking & Adjustment  

 

The bias voltage for this amplifier is 330mv DC 

 

 

The  Stereo  40  6AS7 

uses  the  ‘Split  Bias’  method  of 

valve  operation.  This  has  the  advantage  of  higher 
power, lower feedback and cooler running. However 
it is important that the bias is checked at least twice 
a  year  using  the  supplied  meter  to  ensure  best 
performance from the amplifier.

  

This  is  a  safe  procedure  which  involves  measuring 
0.33v/330mv  in  each  of  the  four  sockets  next  to  each 
6AS7 and adjusting if necessary. This need not be 100% 
accuracy and minus 10% i.e. 300mv to 350mv will have 
virtually no effect. 

 

1, Tools you will need: The supplied meter or one set 
to  measure  approx  2  or  3  volts  DC,  and  a  small  flat 
blade  screwdriver.  Adjustments  are  done  at  zero 
volume with speakers connected. Run the amp for at 
least 20 mins (if it is working correctly). Otherwise do 
a rough adjustment and check later when the ST40 is 
hot. 
The  Icon  meter  reads  in  mv  (millivolt=1v/1000).  So 
0.33v will read 

“330mv”. 

 

2, Connect: the  black prob

e to the chassis ‘earth’ by 

unscrewing  the  ‘0’  speaker  terminal  and  tightening 
the  probe  in  the  exposed  hole.  And  the  other  in  the 
test  socket  adjacent  to  the  valve  on  test.  See  pics.. 
Set  the  ‘Icon’  meter  to  2000mv  (2v)  or  the  ‘black 
mark’.  

 

 

Making the 

‘earth’ connection. 

 

3,  Checking:  You  should  get  a  reading  of  330mv  if 
the  valve  is  working  correctly.  But  bear  in  mind  that 
your  mains  voltage  fluctuations  can  affect  your 
readings up to 10%. Check all valves, they should be 
within about 10% of the ideal voltage.  

 

4,  Adjusting:  If  the  reading  is  incorrect,  set  this  by 
using  the  bias  adjuster  in  the  centre.  They  are  very 
sensitive so adjust very carefully; use tiny turns of the 
screw.  If  the  reading  appears  a  little  unstable  this  is 
normally due to mains fluctuations. 
5, If one or more valves are showing erratic readings 
or you cannot set the correct voltage, then that valve 
is  probably  faulty  or  out  of  specification.  If  you  are 
unable to set the reading high enough this means the 
emission of the valve is low. 

 

 

Showing a probe reading 1

st

 output valve 

 

If  you  are  unsure  about  any  aspect  of  bias  contact 
your  retailer,  Icon  Audio  or  a  competent  service 
engineer. Icon Audio  provides a free bias check and 
“health check” for your amplifier and valves. 

 

Содержание Stereo 40 6AS7 Limited Edition

Страница 1: ...our ears attune themselves to the new sound Your source loudspeakers and room acoustics will also affect the sound before it finally reaches your ear Some people find a small adjustment in re position...

Страница 2: ...wiring check Check Triode mode Run min 6 hour test Check inputs tape monitor Output Valve Bias level mv Sound Quality Channel Balance Valve Microphony Valve Seating Hum level left right mv RF Test LE...

Страница 3: ...switch down The amplifier should now be working 6C The Volume control will re set on switch on to aprox 9pm position There should be no sound coming from the speakers except a barely discernable gent...

Страница 4: ...Page 4...

Страница 5: ...of cables therefore the benefits of very exotic cables may be wasted But this is personal taste Icon or your dealer will advise you As all cables have losses keeping the speaker cables short is best I...

Страница 6: ...e and reliability The upgrade valves supplied with selected models are the result of careful comparison with other makes But beware paying excessive amounts for New Old Stock second hand or Fake copy...

Страница 7: ...may easily be re configured for 110 120v ac Contact us for more information 6 Bias Checking Adjustment The bias voltage for this amplifier is 330mv DC The Stereo 40 6AS7 uses the Split Bias method of...

Страница 8: ...ALENT US 6080 Russian China 6N5 6N13 DO NOT USE ANY OTHER OUTPUT VALVE AS DAMAGE WILL RESULT 8 Replacing the small valves 6SL7 centre and 6SN7 valves Neither of these requires any set up procedure It...

Страница 9: ...countries applicable guarantee law applied You are advised to inform us of any change of address or ownership in order that we may keep you up to date of any upgrades or improvements Check our websit...

Отзывы: