icon Audio Stereo 40 6AS7 Limited Edition Скачать руководство пользователя страница 6

Page 6 

4 How to get the best out of your amplifier 

 

Do not leave the amplifier switched on all the time. This is not necessary 

 

Do not switch off and on without a rest of 60 seconds (this could blow the internal 500ma AS fuses) 

 

Do not adjust the output valve grid bias without reading the procedure 

 

Do not operate the amplifier without loudspeakers connected 

 

Do not use valves other than listed as this could be dangerous and damaging to the amplifier 

 

Remember to check the bias about twice a year for best performance. 

 

Make sure the speakers are in phase. 

 

Use the best possible source material.  

 

Use efficient, well-designed speakers. 

 

What is safe maximum volume? 

The  Stereo  40  6AS7  will  run  happily  all  day  long  at 
maximum  power;  the  valves  are  not  stressed  any 
more  at  full  power  than  at  zero  volume.  Running  into 
gross  distortion  will  however  stress  the  whole 
amplifier.  To  find  the  maximum  safe  volume,  play  full 
range  music  and  advance  the  volume  until  distortion 
occurs, (this is normally between 12 and 3 o’clock on 
the  volume control) back off the volume control about 
30  degrees,  this  is  approximately  full  music  power. 
However  this  position  will  vary  according  to  the  level 
and  type  of  music  and  the  output  of  the  source  unit. 
For  example  CD  players  tend  to  be  higher  than  say 
tuners or phono stages. 

Leaving the amplifier switched on 

Do  not  leave  the  amplifier  switched  on  24/7.  Your 
valves will be worn out in approximately nine months! 
Whilst  the  amplifier  will  sound  at  its  best  when  it  is 
properly  warmed  up,  there  is  no  advantage  leaving  it 
switched  on  when  it  is  not  in  use.  See  (

Standby 

Switch).  We  would  always  advise  that  any  item  of 
home electronics is switched off when not in use 
Standby Switch 

If the amplifier is not needed for a few hours, it can be 
left  in  the  “standby”  state.  This  enables  the  valves  to 
be  fully  warmed  and  ready  to  use  the  instant  you  put 
the standby switch down. In the “standby” position the 
amplifier  is  only  using  about  50%  of  normal  power.  It 
also  enables  a  healthy  cloud  of  electrons  to  build  up 
around  the  hot  cathode.  Also  it  allows  the  silver 

“getter” inside the valve to “mop up” any gas that has 
built  up  inside  and  therefore  keep  the  vacuum  “hard” 
for  best  performance.  There  is  no  benefit  to  leaving 
the  ST40  on  standby  indefinitely.  If  not  in  use  switch 
off! 

 

‘Burning in’ 

Although  the  amp  should  sound  good  within 
about 10 mins it can take up to an hour to sound 
at its best and will take several months of regular 
use before it is 

fully ‘run in’. 

Upgrading Valves! 

Good  quality  new  valves  sound  better,  have  good 
performance  and  reliability.  The  upgrade  valves 
supplied  with  selected  models  are  the  result  of 
careful  comparison  with  other  makes.  But  beware 
paying  excessive  amounts  for 

“New  Old  Stock”, 

second  hand  or  “Fake/copy”,  valves.  At  the  time  of 
writing  (07.2011)  there  are  good  stocks  of  Russian, 
Chinese  and  US  military  valves  (military  number 
6080)  available.  Svetlana  and  Sovtek  are  making 
new 6AS7s. 

Cabinet Care 

To  remove  dust  we  suggest  gentle  brushing  of  the 
polished  stainless  steel  cabinet  with  a  soft 
paintbrush.  Other  marks  can  usually  be  removed 
with  a  damp  cloth.  The  Perspex  valve  cover  may 
need a gentle wipe with soapy water and drying with 
a  duster.  On  no  account  use  anything  wet  on  the 
amplifier,  and  always  clean  with  the  power 
disconnected.  

5 Trouble Shooting 

Amplifier Dead 

Check the amp mains fuse in the small drawer in the IEC 
mains  socket  at  the  back  of  the  amplifier.  To  gain 
access,  remove  the  mains  lead.  The  fuse  is  in  a  small 
plastic drawer, which forms part of the socket assembly. 
To  open  insert  a  flat  bade  screwdriver  or  similar  and 
prise open. 

The fuse in use is the innermost

 the outer 

is a spare. Should the replacement fuse also blow there 
is a fault. Replacem

ents should be 1.6 Amp ‘anti-surge’. 

Available from Icon Audio free

! contact us and we will 

post them to you. 
The  fuse  in  the  UK  wall  plug  should  be  a  3  or  5  amp 
fuse, this should be checked if the amplifier fuse is OK. 

If one channel only, has stopped working it is likely to be 
one of the two internal left and right HT fuses. There are 
2 spares inside. You should refer to  your dealer  or Icon 
Audio if you suspect one of these to have blown. If this is 
not  possible  you  should  disconnect  power  for  20  mins, 
invert  the  amplifier  on  a  soft  surface  and  remove  the 
bottom cover (where the spares are located) and replace 
if  necessary.  If  the  fuse  blows  again  there  is  a  fault. 
Replacement fuses are 500ma AS (or T). 

 

No sound 

Have  you  selected  the  right  input?  Are  the 
connections OK? Is everything switched on? Are the 
speakers connected? 

Distorted sound. 

Try  another  source;  if  sound  improves  then  it’s 
probably something wrong with the first source. If no 
improvement 

try 

different 

speakers, 

if 

no 

improvement could be an amplifier problem. 

Hum Problems 

If you experience hum, try disconnecting all inputs, if 
hum persists this is probably an amplifier fault.  
If  not,  identify  which  input  is  causing  hum.  Connect 
one input at a time. A common cause is a ‘hum loop’ 
caused  by  having  too  many  earths,  and  may  be 
identified  by  unplugging  each  input  source  from  the 
mains. One remedy for this is to use an interconnect 
which  only  has  the  screen  connected  at  one  end. 
Other causes of low-level  hum can be from adjacent 
equipment,  so  experiment  with  moving  equipment 
around to see if this makes the hum better or worse.

 

Содержание Stereo 40 6AS7 Limited Edition

Страница 1: ...our ears attune themselves to the new sound Your source loudspeakers and room acoustics will also affect the sound before it finally reaches your ear Some people find a small adjustment in re position...

Страница 2: ...wiring check Check Triode mode Run min 6 hour test Check inputs tape monitor Output Valve Bias level mv Sound Quality Channel Balance Valve Microphony Valve Seating Hum level left right mv RF Test LE...

Страница 3: ...switch down The amplifier should now be working 6C The Volume control will re set on switch on to aprox 9pm position There should be no sound coming from the speakers except a barely discernable gent...

Страница 4: ...Page 4...

Страница 5: ...of cables therefore the benefits of very exotic cables may be wasted But this is personal taste Icon or your dealer will advise you As all cables have losses keeping the speaker cables short is best I...

Страница 6: ...e and reliability The upgrade valves supplied with selected models are the result of careful comparison with other makes But beware paying excessive amounts for New Old Stock second hand or Fake copy...

Страница 7: ...may easily be re configured for 110 120v ac Contact us for more information 6 Bias Checking Adjustment The bias voltage for this amplifier is 330mv DC The Stereo 40 6AS7 uses the Split Bias method of...

Страница 8: ...ALENT US 6080 Russian China 6N5 6N13 DO NOT USE ANY OTHER OUTPUT VALVE AS DAMAGE WILL RESULT 8 Replacing the small valves 6SL7 centre and 6SN7 valves Neither of these requires any set up procedure It...

Страница 9: ...countries applicable guarantee law applied You are advised to inform us of any change of address or ownership in order that we may keep you up to date of any upgrades or improvements Check our websit...

Отзывы: