TRUNKING/NETWORK CONTROLLER

UC-FR5000

- 4 -

Thank you for choosing this Icom product. 

The controller is designed to be installed into the IC-

FR5000/IC-FR6000 series 

vhf

 /

uhf

 

fm

 

repeaters

 and 

enables the on-line control and digital trunking operation 

on the repeater.

READ ALL INSTRUCTIONS

 carefully and completely 

before using this product.

- 1 -

1.   Unscrew the seven screws from the top, and the two 

screws on both sides of the repeater, then slide the top 

cover off in the direction of the arrow.

P0

P1

P2

P3

P4

Top cover

         Repeater

2.   Disconnect the control cable from the channel module. 

Then, unscrew the seven screws that affix the channel 

module to the repeater chassis, and then remove it.

   

P0

P1

P2

P3

P4

 Control cable

Channel module

Front panel*

Repeater

 *  The front panel is removed in this illustration so the details are 

easier to see. However, you can remove the channel module 

without removing the front panel of the repeater.

3.    Unscrew the eight screws from the top, the nine screws 

from bottom, and the three screws from rear of the 

channel module. Then remove each cover from it.

Channel module

R

 

WARNING!

 Turn OFF the repeater before installing the 

controller. Otherwise a fire, electric shock may occur, or the 

repeater could malfunction.  

CAUTION: NEVER

 expose the repeater or controller to 

rain, snow or any liquids.  

CAUTION: NEVER

 let metal, wire or other objects touch 

any internal part of the controller.

CAUTION:

 Install the controller in only the specified repeater.

 

BE CAREFUL!

 When you install the controller, wear gloves 

to avoid cutting your hand on the sharp edges of the repeater.

PRECAUTIONS

The controller enables the repeater to be used for the 

following modes, depending on the configurations. (This 

table is shown in controllers whose revision number is 3.5 

or later. Ask your dealer for details.)

Single Site

Multi Site

Conventional Trunking Conventional Trunking

UC-FR5000#01

*

1

*

2

*

3

UC-FR5000#02

( CF-FR5000MC is 

supplied)

*

3

UC-FR5000#03

( CF-FR5000MT is 

supplied)

UC-FR5000#04

*

1

*

2

*

3

*

1

   When the optional RS-FS10 remote communicator is used, ei-

ther the CF-FR5000MC or CF-FR5000MT is required.

*

2

  Either the optional CF-FR5000MC or CF-FR5000MT is required.

*

3

  The optional CF-FR5000MT is required.

CONFIGURATIONS

The supplied or optional CF card must be inserted to enable 

the Multi Site Conventional or Trunking mode use. Before 

inserting a CF card to the controller’s card slot, carefully 

read the card’s instructions. 

ABOUT THE CF CARD

DISPOSAL

DISASSEMBLING THE UNITS

The crossed-out wheeled-bin symbol on your 

product, literature, or packaging reminds you 

that in the European Union, all electrical and 

electronic products, batteries, and accumulators 

(rechargeable batteries) must be taken to 

designated collection locations at the end of their working 

life. Do not dispose of these products as unsorted municipal 

waste. Dispose of them according to the laws in your area.

NOTE:

 Internet Explorer 6.0 or later is required to 

correctly open the setting screen of the controller. The 

following instructions are based on using Internet Explorer 

7.0. JavaScript must be installed to open the side menu 

and help window of the Setting screen.

 

D

 Accessing the setting screen

NOTE:

 You must wait to launch the web browser until the 

controller system software startup is completed.It typically 

takes 2 ~ 3 minutes for the controller to

startup the application.

1.   Connect a CAT-5 straight cable between the 

controller’s [LAN] connector and a PC (p. 3) and then 

turn ON the repeater.

2.   Before accessing the Setting screen, change the IP 

address of the PC to 192.168.0.XXX* (A subnet mask 

should be 255.255.255.0) in the Control Panel.

    *  

Replace XXX with any number between 1 and 254 (except 11).

L

 Refer to the Operating System’s manual for details.

3.   Open your web browser, enter “http:// 192.168.0.11/” 

(default IP address of the UC-FR5000) into the address 

bar, and then push [Enter].

 

 

The Login Authentication screen is displayed.

L

 Ask your system administrator for details.

4.   

Enter “cbadmin” (default user name) and “ucfr5000”

 

(default password) in their respective input field in the 

Login Authentication screen, and then click <OK>. 

     If you want the screen to remember not only the 

user name but also the password, check the box, 

“Remember my password”. 

 

 

The Opening screen is displayed.

  

TIP:

 You can change the user name and password 

in the Setting screen. Refer the help window of the 

Setting screen for details.

Enter 

Enter 

Check

Click 

THE SETTING SCREEN OF THE UC-FR5000

 

D

Opening the help window

The Setting screen of the controller has a help window to 

describe functions and settings.

If you don’t understand the meaning of an item, or how to 

configure the controller, click a question mark icon on the 

screen to open the help window.

Click to open the help window for 

“General Settings,” for example. 

 

D

Initialization

You can reset all set contents, including the network settings 

of the controller, to the factory default from the PC.
1.   Connect the controller to the PC, and then turn ON the 

repeater.

2.   

Open your web browser, enter the initialize address into 

the address bar, and then push [Enter].

 

The initialize screen is displayed.

L

 

Initialize address:

 http://(IP address):8080/init.html

L

  When the IP address of the controller is 192.168.0.11*, enter 

“http://192.168.0.11:8080/init.html” as the initialize address.

 

*  The IP address is an example only. Check the IP address 

of the controller. 

3.   After checking the box “Yes, I agree,” click <RESET>  

to initialize the settings. 

TIP:

 If you use the UC-FR5000 #03, you can 

select whether or not to reset the Network settings 

as well as other settings. Refer to the help window 

for details. 

L

  This screen slightly differs, depending on the Operating 

System version.

*This  illustration 

is described with 
the UT-105.

Enter 

Check

Click