2
2
INSTALLATION AND CONNECTIONS
■
Connection
CAUTION: Before connecting, make sure discon-
necting the radar unit’s DC power cable from the
battery.
12 V/24 V
battery
Radar unit
KEEP
the terminal
guard attached after
connecting cables.
NOTE:
Use the termi-
nals as shown below for
the cable connections.
Solder
Crimp
Turn the power OFF.
Ground
NEVER
connect anything other
than the supplied scanner unit.
Supplied scanner unit
MarineCommander™
MXP-5000
Terminal guard
GND
DC IN
12V/24V
NC
Detach the terminal guard first.
■
Power source requirement
CAUTION: Before connecting the DC power cable,
check the following important items. Make sure:
• Output voltage of the power source is 12 V/24 V
DC.
• DC power cable polarity is correct.
Red
: Positive
+
terminal
Black : Negative
_
terminal
• Fuse rating of the DC power cable is correct. (The
10 A fuse is pre-installed.)
5 A
: For 24 V power source
10 A : For 12 V power source
■
Ground connection
To prevent electrical shocks and other problems,
ground the radar unit through the [GND] terminal. For
best results, connect a heavy gauge wire or strap to
the nearest grounding point on the boat. The distance
between the [GND] terminal and the ground point
should be as short as possible.
■
Mounting
First, drill four Ø5.5–6 mm (0.22–0.24 in) holes to
mount the radar unit using the units base as a pattern.
Mount the radar unit securely with the four supplied
bolts (M5
×
30 mm) to a flat surface which supports
more than approx. 5 kg (11 lb).
CAUTION: KEEP the radar unit at least 1.8 meter
(5.9 ft) away from your vessel’s magnetic naviga-
tion compass.
Flat washer
Flat washer
Spring washer
Spring washer
Bolt
Nut