8
3
PREPARATION
New2001
■
MMSI code setting (Continued)
r
Push
[ENT] to enter the MMSI code setting mode.
t
Push
[
∫
] or [
√
] to input the specific 9-digit MMSI code.
• Push
[
≈
] to move the cursor forward.
• Push
[
Ω
] to move the cursor backward.
• Push
[CLEAR] to cancel, and go to the plotter display. In this
case, the transponder operates as just an AIS receiver.
[CLEAR]
[ENT]
[
∫
], [
√
],
[
Ω
], [
≈
]
NOTE: The coast station ID or the group ID cannot be en-
tered as your MMSI code.
• Group ID
: The first one digit is “0.”
• Coast station ID : The first two digits are “0.”
If you enter a code that starts with “0” or “00,” an error beep
sounds after pushing
[ENT] in step
y
.
y
After inputting the 9-digit code, push
[ENT].
• The MMSI confirmation screen appears.
u
Input the same MMSI code which was entered in steps
t
and
y
for the confirmation. Then, push
[ENT] to save.
i
After the MMSI code has been saved, the transponder au-
tomatically enters the Initial setting mode. See pages 9 to
13 for setting details.
The Initial setting mode can also be entered from the
Menu mode. (p. 9)