Cmd.
Sub cmd.
Data
Description
00
Output the frequency data for transceive
01
Output the receiving mode for transceive
02
Read the band edge frequencies
03
Read the receiving frequency
04
Read the receiving mode
05
Set the receiving frequency
06
Select the receiving mode
07
Select the VFO mode
08
Select the Memory mode
0000 ~ 0199 Select the Memory channel
( 0000 ~ 0099: Normal Memory
channels/Scan Skip
channels/Scan edges)
(000 0 ~ 0199: Auto Memory Write
channels)
A0
0000 ~ 0102 Select the Memory group
( 0000 ~ 0099: Normal Memory channels
0100: Auto Memory Write channels
0101: Scan Skip channels
0102: Scan edges)
09
Memory write
0A
Memory copy to VFO
0B
Memory clear
0C
Read offset frequency
0D
See p. 9
Set offset frequency
0E
00
Scan stop
01
Programmed/memory scan start
02
Programmed scan start
03
∂
F scan start
04
Auto Memory Write scan start
12
Fine Programmed scan start
13
Fine
∂
F scan start
22
Memory scan start
23
Select memory scan start
24
Mode Select scan start
42
Priority scan start
A0
Set the Fix of
∂
F frequency to OFF
AA
Set the Fix of
∂
F frequency to ON
Ax
Set/read the Fix range (x) of
∂
F frequency
(1=±5kHz, 2=±10kHz, 3=±20kHz,
4=±50kHz, 5=±100kHz, 6=±500kHz,
7=±1MHz)
B0
Set as non-select channel
B1
Set as select channel
( If no selection is performed, the
previously set number by CI-V is set
after turning power ON, otherwise “1” is
automatically set.)
01 ~ 09
Set as select channel
(01=SEL1, 02=SEL2, 03=SEL3,
04=SEL4, 05=SEL5, 06=SEL6,
07=SEL7, 08=SEL8, 09=SEL9)
B2
00 ~ 09
Set starting select memory channel for a
select memory scan
(00=ALL, 01=SEL1, 02=SEL2,
03=SEL3, 04=SEL4, 05=SEL5,
06=SEL6, 07=SEL7, 08=SEL8,
09=SEL9)
D0
Set Scan resume OFF
D1
Set Scan resume ON (Close timer)
D3
Set Scan resume ON (Close & Delay)
0F
10 ~ 12
Read duplex setting
(10=OFF, 11=DUP–, 12=DUP+)
10
Set Simplex
11
Set Duplex –
12
Set
10*
00
Send/read the tuning step OFF(in 10 Hz
steps)
01
Send/read the 100 Hz tuning step
02
Send/read the 1 kHz tuning step
03
Send/read the 2.5 kHz tuning step
04
Send/read the 3.125 kHz tuning step
05
Send/read the 5 kHz tuning step
06
Send/read the 6.25 kHz tuning step
07
Send/read the 8.33 kHz tuning step
08
Send/read the 9 kHz tuning step
09
Send/read the 10 kHz tuning step
10
Send/read the 12.5 kHz tuning step
11
Send/read the 20 kHz tuning step
Cmd.
Sub cmd.
Data
Description
10*
12
Send/read the 25 kHz tuning step
13
Send/read the 100 kHz tuning step
14
Send/read the programmable tuning step
11*
00
Send/read Attenuator OFF (0 dB)
10
Send/read Attenuator (10 dB)
20
Send/read Attenuator (20 dB)
30
Send/read Attenuator (30 dB)
12*
00 ~ 02
Select antenna (only 10 kHz –
29.999999 MHz)
(00=ANT1, 01=ANT2, 02=ANT3)
13
00
Speech all parameters
( Signal level + Fre Receiving
mode)
01
Speech frequency
(Signal level + Frequency)
02
Speech receiving mode
L
The mode is announced after the
ongoing speech.
14*
01
0000 ~ 0255 Send/read the AF gain level
(0000=Minimum ~ 0255=Maximum)
02
0000 ~ 0255 Send/read the RF gain level
(0000=Minimum ~ 0255=Maximum)
03
0000 ~ 0255 Send/read the squelch level
(0000=Minimum ~ 0255=Maximum)
06
0000 ~ 0255 Send/read the NR level
(0000=0% ~ 0255=100%)
07
0000 ~ 0255 Send/read the PBT1 position
(0000=Narrow the upper edge,
0128=Center position,
0255=Narrow the lower edge)
08
0000 ~ 0255 Send/read the PBT2 position
(0000=Narrow the upper edge,
0128=Center position,
0255=Narrow the lower edge)
09
0000 ~ 0255 Send/read CW pitch
(0000=300 Hz, 0128=600 Hz,
0255=900 Hz) (in 5 Hz steps)
0D
0000 ~ 0255 Send/read the NOTCH position
(0000=A lower position,
0128=Center position,
0255=A upper position)
12
0000 ~ 0255 Send/read the NB level
(0000=0% ~ 0255=100%)
19
0000 ~ 0255 Send/read the LCD brightness
(0000=0% ~ 0255=100%)
1B
0000 ~ 0255 Send/read the tone (Bass) level
(0000=–15, 0128=0, 0255=+15)
1C
0000 ~ 0255 Send/read the tone (Treble) level
(0000=–15, 0128=0, 0255=+15)
1D
0000 ~ 0255 Send/read the Scan Speed
(0000=1, 0128=16, 0255=30)
1E
0000 ~ 0255 Send/read the Scan Delay
(0000=1s, 0128=16s, 0255=30s)
1F
0000 ~ 0255 Send/read the PRIO Interval
(0000=1s, 0128=8s, 0255=15s)
15
01
00/01
Read noise or S-meter squelch status
(00=Close, 01=Open)
02
0000 ~ 0255 Read the S-meter level
(0000=S0, 0120=S9, 0241=S9+60dB)
03
Read the meter level in the
"AAAABBCC" Format:
AAAA= Absolute signal strength (in
0.1 steps)
BB= Plus or minus sign (0/1=+/–)
CC= Meter type (0/1/2=dBμ/dBμEMF/
dBm)
04
0000 ~ 0255 Read the center meter level
( 0000= Left edge, 0128= Center,
0255= Right edge)
05
00/01
Read various squelch function’s
(including the tone squelch) status
(00=Close, 01=Open)
17
00/01
Read the S-AM SYNC Indicator
( 00=Non-synchronous,
01=Synchronous)
18
00/01
Read the OVF indicator status
(00=OFF, 01=ON)
16*
02
00/01
Send/read the Preamp status
(00=OFF, 01=ON)
12
01 ~ 03
Send/read the AGC function status
( 01=FAST, 02=MID, 03=SLOW)
D
Command table
Remote control
3