manualshive.com logo in svg
background image

CI-V REFERENCE GUIDE

iR8600

COMMUNICATIONS RECEIVER

Содержание iR8600

Страница 1: ...CI V REFERENCE GUIDE iR8600 COMMUNICATIONS RECEIVER...

Страница 2: ...Table of contents 1 1 REMOTE CONTROL 2 REMOTE CONTROL CI V INFORMATION 2 D D CI V connection 2 D D Preparation 2 D D Data format 2 D D Command table 3 D D Command formats 9...

Страница 3: ...system can be written using the following data formats Data formats differ according to command numbers A data area or sub command is added for some commands Controller to IC R8600 IC R8600 to control...

Страница 4: ...tuning step 11 Send read the 20 kHz tuning step Cmd Sub cmd Data Description 10 12 Send read the 25 kHz tuning step 13 Send read the 100 kHz tuning step 14 Send read the programmable tuning step 11 0...

Страница 5: ...Send read the de emphasis 15k 00 OFF 01 ON 0006 00 01 Send read the de emphasis 7k 00 OFF 01 ON D D Command table Continued Cmd Sub cmd Data Description 1A 05 0007 00 30 Send read the WFM audio tone B...

Страница 6: ...01 IF 0069 0000 0255 Send read the AF output level of AF IF 0000 0 0255 100 D D Command table Continued Cmd Sub cmd Data Description 1A 05 0070 00 01 Send read the audio output setting for AF IF 00 OF...

Страница 7: ...read the display background type 00 A 01 B 0118 00 01 Send read the Meter Peak Hold function 00 OFF 01 ON 0119 00 01 Send read the Memory name display 00 OFF 01 ON Cmd Sub cmd Data Description 1A 05 0...

Страница 8: ...l 00 1 09 10 0177 0000 0255 Send read the Noise Blanker width Blanking period 0000 1 0255 100 0178 00 01 Send read the Memory group type 00 Current group 01 All groups 0179 00 01 Send read the scannin...

Страница 9: ...lected or not selected VFO s operating mode and filter 27 00 See p 21 Read the Scope waveform data 10 00 01 Send read the Scope ON OFF status 00 OFF 01 ON 11 2 00 01 Send read the Scope wave data outp...

Страница 10: ...h command 01 and the default filter setting of the receiving mode is automatically selected with command 06 Band edge frequency Command 02 q w e r t y u i o 0 1 X X X X X X X X X X 2 D X X X X X X X X...

Страница 11: ...05 0142 0146 0161 0166 0167 q w e r t y R Red G Green B Blue 1000 0 Fixed 100 10 1 1000 0 Fixed 100 10 1 1000 0 Fixed 100 10 1 Setting range for each color 0000 0255 X X 0 X 0 X X X 0 X X X Character...

Страница 12: ...to Receiving frequency p 9 1 2 Receiving mode Refer to Receiving mode p 9 3 Duplex setting 0 OFF 1 DUP 2 DUP 3 0 X 0 Fixed Memory channel content Command 1A 00 X X X X X X X X X X X X X X X X X X X X...

Страница 13: ...ed 3 5 Tone squelch frequency Refer to TSQL frequency p 14 6 8 DTCS code Refer to DTCS code p 14 2 Digital squelch D SQL type 0 OFF 1 NAC 2 0 X 0 Fixed 3 5 NAC 3 4 5 Once position 0 F 0 Fixed 10th pos...

Страница 14: ...0 Fixed 7 9 Scrambler key 7 8 9 0 X X X X X Once position 0 9 10th position 0 9 100th position 0 9 1000th position 0 9 10000th position 0 3 0 Fixed 2 Digital squelch D SQL type 0 OFF 1 RAN 2 0 X 0 Fix...

Страница 15: ...0000th position 0 3 0 Fixed 0 X X X X X Command 1A 00 clears a memory channel by sending the command in the following format q w 0000 0101 group You cannot specify group 0102 Program scan edge e r Mem...

Страница 16: ...e power was turned ON D STAR RX message Command 20 0101 20 0102 9 2 1 8 q 0 X X X X X X X X X X X X q 0 Message 20 characters 1 8 Call sign of the CALLER station 8 characters 9 2 Note of the CALLER st...

Страница 17: ...that is not contained the received data is filled with FF LFF No signal has been received since the power was turned ON GPS D PRS data Object 1 7 8 9 0 1 2 2 3 6 q o 0 2 6 7 2 9 1 2 8 3 1 X X X X X X...

Страница 18: ...ived since the power was turned ON Weather 1 0 1 2 3 4 5 6 5 3 9 q o 0 2 6 7 2 6 8 9 2 4 7 9 0 1 3 X X X X X X X X X X X X X X X X X X X X Data No X X X X X X 0 3 X X X X X X X X X X X X X X X X X X X...

Страница 19: ...4 0 1 Last call finisher When the last call was finished by a user 1 is returned bit3 0 1 Receiving a signal When the audio tone can be heard 1 is returned bit2 0 1 Emergency call While receiving an e...

Страница 20: ...1 1 All call 1 0 Group call 0 1 Individual call 0 0 Not identified wHeader flag data Second byte Data Description bit7 0 Fixed bit6 0 Reserved bit5 0 Reserved bit4 0 Reserved bit3 0 Reserved bit2 0 Re...

Страница 21: ...ALLED station is not identified FF is returned LFF No signal has been received since the power was turned ON DCR RX Status data Command 20 0D01 20 0D02 Data Function Description bit7 0 Fixed bit6 0 1...

Страница 22: ...ximum means the maximum divided number The division number Now means the number that indicates the divided data location Example Sending the 5th data of divided into 11 The division number Now is 5 an...

Страница 23: ...B di g i t 0 1 2 1 dB d i g i t 0 9 0 1 dB digit 0 5 0 01 dB di g i t 0 Fixed 0 0 X X X 0 X X LAdjustable range 20 0 dB 20 0 dB in 0 5 dB steps Sweep speed settings Command 27 1A 00 FAST 01 MID 02 SLO...

Страница 24: ...1 1 32 Kamiminami Hirano ku Osaka 547 0003 Japan A 7375 2EX w 2017 Icom Inc...