5 - 4
ADJUSTMENT
ADJUSTMENT CONDITION
OPERATION
VALUE
S-meter
[Sr]
NOTE:
“RECEIVE SENSITIVITY” should be adjusted before “S-meter.”
Otherwise, “S-meter” will not be adjusted properly.
1 •
•
Set the SSG as;
Frequency : Displayed frequency
Level
: −6 dBu (−113 dBm)
Receiving
Push
[CLR]
key to store the adjustment value and
select the next adjustment item.
(automatic
adjustment)
[dF]*
Push [
Y
] to skip this item.
[Et]*
Push [
Y
] to skip this item.
CTCSS
AMPLITUDE
(f=5.00 kHz)
[C5]
NOTE:
“DTCS MODULATION BALANCE” (page 5-3) should be adjusted before “CTCSS AMPLITUDE.”
Otherwise, “CTCSS AMPLITUDE” will not be adjusted properly.
1 •
•
•
Set the Modulation Analyzer same as
“DEVIATION.”
No audio signal is applied to the MIC line.
Transmitting
Rotate
[CONTROL DIAL]
during transmit to
adjust the daviation, then release the
[PTT]
and
push
[CLR]
key to store the adjustment value.
±0.75 kHz
(f=6.25 kHz)
[C6]
2
[dt]* to [D6]*
Skip these items. (The adjustment is completed. Turn the power OFF.)
¤
ADJUSTMENT (continued)
*; These items MUST NOT be modifi ed. Otherwise, the transceiver will not perform properly.