18
5
RECEIVE FUNCTIONS
■
Filter selection
The filter selection switches the IF passband width as
shown in the table at right.
The filter selection is automatically memorized in
each mode.
q
Select the desired mode with the mode switches.
w
Push [FIL] one or more times to select the desired
filter combination.
•
ã
or
ç
does not appear while in normal IF filter.
•
ç
appears when wide IF filters are selected.
•
ã
appears when narrow IF filters are selected.
When an optional filter is installed, set the optional
filter in filter set mode. Optional filters are not se-
lected by default.
• Filter construction
CFWS450E (15 kHz)
CFWS450HT (6 kHz)
FL-65 (2.4 kHz)
FL-257 (3.3 kHz)
FL-96 (2.8 kHz)
FL-222 (1.8 kHz)
FL-52A (500 Hz)
FL-53A (250 Hz)
optional
FL-23 (15 kHz)
FL-272 (2.4 kHz)
FL-103 (2.8 kHz)
FL-223 (1.9 kHz)
FL-100 (500 Hz)
FL-232 (350 Hz)
FL-101 (250 Hz)
optional
Mixer
2nd IF signal
3rd IF signal
9 MHz IF filter
455 kHz IF filter
IF
Filter
Passband
width
Recommended
selectivity
9 MHz
FL-100
500 Hz/–6 dB
CW-N, RTTY-N
FL-101
250 Hz/–6 dB
FL-103
2.8 kHz/–6 dB SSB-W
CW-N
FL-223
1.9 kHz/–6 dB SSB-N
455 kHz
FL-52A
500 Hz/–6 dB
CW-N, RTTY-N
FL-53A
250 Hz/–6 dB
CW-N
FL-96
2.8 kHz/–6 dB SSB-W
FL-232
350 Hz/–6 dB
CW-N, RTTY-N
FL-222
1.8 kHz/–6 dB SSB-N
FL-257
3.3 kHz/–6 dB SSB-W