![Icom IC-R5 Скачать руководство пользователя страница 20](http://html2.mh-extra.com/html/icom/ic-r5/ic-r5_service-manual_3583643020.webp)
5 - 7
S-METER
ADJUSTMENT
ADJUSTMENT CONDITION
OPERATION
1
2
3
4
5
6
7
8
9
10
11
12
• Displayed frequency
: (SM ch) 14.100 MHz
• Connect the SSG to the antenna connector and set as :
Level
: 0.5 µV
*
(–113 dBm)
Modulation
: OFF
• Mode
: FM
• Receiving
• Set the SSG as :Level : 1.6 µV
*
(–103 dBm)
• Mode
: WFM
• Receiving
• Displayed frequency
: (SM ch) 145.100 MHz
• Set the SSG level
: 0.5 µV
*
(–113 dBm)
• Mode
: FM
• Receiving
• Set the SSG level
: 1.6 µV
*
(–103 dBm)
• Mode
: WFM
• Receiving
• Displayed frequency
: (SM ch) 200.100 MHz
• Set the SSG level
: 0.5 µV
*
(–113 dBm)
• Mode
: FM
• Receiving
• Set the SSG level
: 1.6 µV
*
(–103 dBm)
• Mode
: WFM
• Receiving
• Displayed frequency
: (SM ch) 435.100 MHz
• Set the SSG level
: 0.5 µV
*
(–113 dBm)
• Mode
: FM
• Receiving
• Set the SSG level
: 1.6 µV
*
(–103 dBm)
• Mode
: WFM
• Receiving
• Displayed frequency
: (SM ch) 650.100 MHz
• Set the SSG Level
: 0.5 µV
*
(–113 dBm)
• Receiving
• Set the SSG level
: 1.6 µV
*
(–103 dBm)
• Mode
: WFM
• Receiving
• Displayed frequency
: (SM ch) 1100.100 MHz
• Set the SSG level
: 1 µV
*
(–107 dBµ)
• Receiving
• Set the SSG level
: 3.2 µV
*
(–97 dBm)
• Mode
: WFM
• Receiving
*This output level of the standard signal generator (SSG) is indicated as SSG’s open circuit.
Push and hold the [MOD] key.
• Verify that S-Meter shows S4 (3dots).
ADJUSTMENT MODE ADJUSTMENTS (Continued)
• The following adjustments must be performed at “ADJUSTMENT MODE”.