31
6
SCAN OPERATION
Scan edges can be programmed in the same manner as
memory channels. Scan edges are programmed into scan
edges, 0A/0B to 49A/49B, in memory channels.
q
Push the desired band’s [VFO/MR•S.MW] once or twice
to select VFO mode.
w
Set the edge frequency of the desired frequency range:
➥
Set the frequency using the same band’s [DIAL].
➥
Set other data (e.g. tone squelch, etc.), if desired.
e
Push and hold the same band’s [VFO/MR•S.MW] for
1 sec. to enter select memory write mode.
• “
!
” indicator and the memory channel number blink.
r
Rotate [DIAL] to select one of scan edge channel, 0A to
49A.
t
Push and hold [VFO/MR•S.MW] for 1 sec. to program.
• 3 beeps sound and VFO mode is automatically selected.
• Scan edge 0B to 49B is automatically selected when continuing
to hold [VFO/MR•S.MW] after programming.
y
To program a frequency for the other pair of scan edges,
0B to 49B, repeat steps
w
to
r
.
• If the same frequency is programmed into a pair of scan edges,
programmed scan will not function.
[EXAMPLE]: Programming 144.000 MHz into scan edge 1A.
Push
Rotate for setting frequency, etc.
Push for 1 sec.
Rotate
Push for 1 sec. and continue to push
➠
Beep
“
Beep
Beep
Beep
“
“
“
“
“
Beep
Beep
“
“
S.MW
VFO/MR
S.MW
VFO/MR
S.MW
VFO/MR
Release
S.MW
VFO/MR
■
Scan edges programming