5 - 4
ADJUSTMENT
OPERATION
VALUE
S-METER
[NS0]–[WS6]
1 • Set the SSG as;
Frequency
: Specifi ed frequency*
Modulation :
None
Level
: Specifi ed level
†
Automatic adjustment
2 • Push
[TS•MODE]/[SET•SKIP]
to store the adjustment value.
3 • Repeat 1–2 for each specifi ed frequency and value for [NS0] to [WS6].
S-METER FLATNESS
[L1]–[LEH]
1 • Set the SSG as;
Frequency
: Specifi ed frequency*
Modulation :
None
Level
: Specifi ed level
†
Automatic adjustment
2 • Push
[TS•MODE]/[SET•SKIP]
to store the adjustment value.
3 • Repeat 1-2 for each specifi ed frequency and value for [L1] to [LEH].
BAND SCOPE
[SC0]–[SC6]
1 • Set the SSG as;
Frequency
: Specifi ed frequency *
Modulation :
None
Level
: Specifi ed level
†
Automatic adjustment
2 • Push
[TS•MODE]/[SET•SKIP]
to store the adjustment value.
3 • Repeat 1–2 for each specifi ed frequency and value for [SC0] to [SC6].
CENTER METER
[CML] (LOW)
1 • Set the SSG as;
Frequency
: 3 kHz lower than specifi ed frequency*
Modulation :
None
Level
: +34 dBµ (–73 dBm)
‡
Automatic adjustment
2 • Push
[TS•MODE]/[SET•SKIP]
to store the adjustment value.
[CMH] (HIGH)
1 • Set the SSG as;
Frequency
: 3 kHz higher than specifi ed frequency*
Modulation :
None
Level
: +34 dBµ (–73 dBm)
‡
2 • Push
[TS•MODE]/[SET•SKIP]
to store the adjustment value.
SQUELCH
[SQL]
1 • Set the SSG as;
Frequency
: Specifi ed frequency*
Mode
:
FM
Modulation
: 1 kHz
Deviation
: 3.5 kHz
Level
: –13 dBµ (–120 dBm)
‡
Automatic adjustment
2 • Set the [SQL] value to close the squelch with [DIAL]. Then set the
[SQL] value at the point where the audio signals just appear.
3 • Turn the SSG output OFF, and verify that the squelch is closed.
4 • Push
[TS•MODE]/[SET•SKIP]
to store the adjustment value.
RSSI
[RS0]–[RS6]
1 • Set the SSG as;
Frequency
: Specifi ed frequency*
Modulation :
None
Level
: Specifi ed level
†
Automatic adjustment
2 • Push
[TS•MODE]/[SET•SKIP]
to store the adjustment value.
3 • Repeat 1–2 for each specifi ed frequency and value for [RS0] to [RS6].
RSSI FLATNESS
[R5L]–[R8H]
1 • Set the SSG as;
Frequency
: Specifi ed frequency*
Modulation :
None
Level
: Specifi ed level
†
Automatic adjustment
2 • Push
[TS•MODE]/[SET•SKIP]
to store the adjustment value.
3 • Repeat 1–2 for each specifi ed frequency and value for [R5L] to [R8H].
*Displayed on the controller's display.
5-2 MAIN-A UNIT ADJUSTMENT (coninued)
‡
The output level of the standard signal generator (SSG) is indicated as the SSG's open circuit.
†
Refer to the “ADJUSTMENT ITEM LIST“ on page 5-7.
–
–
–
–
–