5-1
SECTION 5. ADJUSTMENT
PROCEDURE
M
GENERAL CONNECTION
5-1 PREPARATION
EQUIPMENT
GRADE AND RANGE
EQUIPMENT
GRADE AND RANGE
Cloning software
CS-F8100 CLONING SOFTWARE
(Revision 1.0 or later)
Standard signal
generator (SSG)
Frequency range:
0.1–50 MHz
Output level:
–20 dBµ to 90 dBµ
(–127 to –17 dBm)
RF power meter
(50
terminated)
Measuring range:
0.1–300 W
Frequency range:
0.1–50 MHz
SWR:
Less than 1.2 : 1
Frequency counter
Frequency range:
0.1–50 MHz
Frequency accuracy: ±1 ppm or better
Input level:
Less than 1 mW
AC millivoltmeter
Measuring range:
10 mV to 10 V
Dummy load
Input impedance:
50
Capacity:
More than 300 W
Audio generator
(AG)
Frequency range:
300–3000 Hz
Output level:
1–500 mV
External speaker
SP-35L
Voltmeter
Measuring range:
0.1–10 V
DC power supply
Voltage:
13.8
V
Capacity:
More than 40 A
Ammeter
Measuring range:
0.1–40 A
M
REQUIRED EQUIPMENTS
To the antenna connector
DUMMY LOAD
(50
Ω
/300 W)
RF POWER METER
(300 W/50
Ω)
AMMETER
(0.1–40 A)
Fuses
30 A
DC power supply
(13.8 V/40 A)
⊕ −
Black
Red
⊕
Red
⊕
−
Black
−
−
Supplied DC cable
STANDARD SIGNAL GENERATOR
(0.1–50 MHz)
AC MILLIVOLT METER
(10 mV to 10 V)
EXT. SPEAKER
(2 W/8
Ω)
3.5(d) mm monoral plug
+
–
+
–
NEVER TRANSMIT
while an SSG is connected.
FREQUENCY COUNTER
(0.1–50 MHz)
(Loose Coupling)
USB
ACC
ANT
ATU
DC
SP
The tests described in Section 5 should be measured and adjusted the with above test equipment, or a radio
tester. The adjustments are described with the radio tester.