background image

ii

PRECAUTIONS

R

 WARNING! NEVER

 connect the transceiver to an 

AC outlet. This may pose a fire hazard or result in an electric 
shock.

R

 WARNING! NEVER

 connect the transceiver to a 

power source of more than 16 V DC or use reverse polarity. 
This could cause a fire or damage the transceiver.

R

 WARNING! NEVER

 cut the DC power cable be-

tween the DC plug and fuse holder. If an incorrect connection 
is made after cutting, the transceiver might be damaged.

R

 WARNING! NEVER

 place the transceiver where 

normal operation of the vehicle may be hindered or where it 
could cause bodily injury.

CAUTION:

 

NEVER

 allow children to touch the trans-

ceiver.

CAUTION:

 

NEVER

  expose  the  transceiver  to  rain, 

snow or any liquids.

USE

 the specified microphone only. Other microphones 

have different pin assignments and may damage the trans-
ceiver.

DO NOT

 use or place the transceiver in areas with tem-

peratures below –25°C or above +55°C, or in areas subject 
to direct sunlight, such as the dashboard.

DO NOT

 operate the transceiver without running the ve-

hicle’s engine. The vehicle’s battery will quickly run out when 
the transceiver transmits while the vehicle’s engine is OFF.

DO NOT

 place the transceiver in excessively dusty envi-

ronments.

DO NOT

 place the transceiver against walls. This will ob-

struct heat dissipation.

DO NOT

 use harsh solvents such as benzine or alcohol 

when  cleaning,  as  they  will  damage  the  transceiver  sur-
faces.

BE CAREFUL!

 The transceiver will become hot when 

operating continuously for long periods of time.

Approved Icom optional equipment is designed for optimal 
performance when used with an Icom transceiver.
Icom is not responsible for the destruction or damage to an 
Icom transceiver in the event the Icom transceiver is used with 
equipment that is not manufactured or approved by Icom. 

Содержание iC-F5012

Страница 1: ...INSTRUCTION MANUAL Limited functions only VHF MOBILE TRANSCEIVER iF5012 UHF MOBILE TRANSCEIVER iF6012...

Страница 2: ...WORD DEFINITION R WARNING Personal injury fire hazard or electric shock may occur CAUTION Equipment damage may occur NOTE If disregarded inconvenience only No risk of personal injury fire or electric...

Страница 3: ...mage the trans ceiver DO NOT use or place the transceiver in areas with tem peratures below 25 C or above 55 C or in areas subject to direct sunlight such as the dashboard DO NOT operate the transceiv...

Страница 4: ...ng ON the power 7 Channel selection 7 Call procedure 8 Receiving and transmitting 8 User Set mode 10 Scrambler function 11 Stun function 11 Priority A channel selection 11 Emergency transmission 12 MD...

Страница 5: ...et p 10 w MICROPHONE CONNECTOR Connect the supplied or optional microphone NEVER connect non specified microphones The pin assignments may be different and the transceiver may be damaged e DEALER PROG...

Страница 6: ...hen a pre programmed key function is activated NOTE When the supplied DC voltage is high all LEDs blink Check the DC voltage D MICROPHONE The supplied or optional microphone has a PTT switch and a han...

Страница 7: ...ng the cleared channel is added to the scan list again after the scan is cancelled PRIO A B KEYS Push to select Priority Channel A or B To rewrite the operating channel as Priority A or Priority B hol...

Страница 8: ...requency to the receive frequency for transceiver to transceiver communication WIDE NARROW KEY Push to toggle the IF bandwidth between wide and narrow The wide passband width can be selected from 25 0...

Страница 9: ...med push this key to temporarily disable the function Push this key again to enable the function USER SET MODE KEY Hold down for 1 second to enter the User Set mode During User Set mode push this key...

Страница 10: ...lected with external input operation only When the function is turned OFF memory channels can be selected with CH Up or CH Down operation or with exter nal input operation This function is available w...

Страница 11: ...ll blink after inputting 4 dig its the input code number may be incorrect Turn OFF the power and re enter your password Channel selection There are several methods to select channels and they may diff...

Страница 12: ...Push CH Up or CH Down to select a channel e When receiving a call rotate VOL to adjust the audio out put level to a comfortable listening level NOTE Depending on the preprogramming the transceiver au...

Страница 13: ...transmission exceeds the pre programmed time out timer limit the transmission is cut off Penalty timer After the transmission is cut off by the time out timer trans mission is further inhibited for t...

Страница 14: ...own P0 for 1 second again TX RX 1 2 3 4 P0 r Push P0 several times to select the appropriate item then push P2 or P3 to set the desired level or setting Selectable set mode items are Backlight Beep ON...

Страница 15: ...operate the transceiver again in this case When the Kill ID is received a beep sounds and the trans ceiver becomes unusable the transceiver switches to the cloning required condition Cloning the trans...

Страница 16: ...ansmitting the call If your transceiver is programmed for Silent operation you can transmit emergency calls without the beep sounding and the LEDs lighting IMPORTANT It is recommended to set an emerge...

Страница 17: ...send an Emergency MDC 1200 system command once or repeatedly for a programmed number of times until it re ceives an acknowledgement signal The emergency call can be transmitted without a beep sound d...

Страница 18: ...er to the vehicle s ground for microphone on off hook functions See page 2 r OPTIONAL CABLE OPC 1939 OPC 2078 t t DC POWER RECEPTACLE Connect to a 12 V DC battery Pay attention to polarities Optional...

Страница 19: ...Felt Spring washer When using self tapping screws Felt reduces the effects of vibration CONNECTION AND MAINTENANCE 3 1 2 16 15 14 13 12 11 10 9 8 7 6 5 4 15 3 Microphone Microphone hanger and screw s...

Страница 20: ...cloth DO NOT use harsh solvents such as benzine or alcohol as they will damage the transceiver sur faces Options OPC 1132A OPC 347 dc power cable 2 fuse holders are attached USE only a 20 A fuse OPC 1...

Страница 21: ...gnation Signature Authorized representative name Place and date of issue Version where applicable 136 174 MHz 12 5 kHz 25 kHz 136 174 MHz 12 5 kHz 20 kHz 0168 Y Furukawa General Manager Icom Europe Gm...

Страница 22: ...HF TRANSCEIVER iC f6012 9th Feb 2011 Bad Soden Declare on our sole responsibility that this equipment complies with the essential requirements of the Radio and Telecommunications Terminal Equipment Di...

Страница 23: ...nd Italy Latvia AT BE BG HR CZ CY DK EE FI FR DE GR HU IS IE IT LV 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 Liechtenstein Lithuania Luxembourg Malta Netherlands Norway Poland Portugal Romania S...

Страница 24: ...Osaka 547 0003 Japan A 6905H 1EU q Printed in Japan 2011 Icom Inc Printed on recycled paper with soy ink Intended Country of Use AT FI IT PL GB RO BE FR LV PT IS TR CY DE LT SK LI HR CZ GR LU SI NO DK...

Отзывы: