background image

40

6

OPTIONS

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

D

 

Setting the VOX gain

The VOX sensitivity level can be adjusted from 1 (minimum) to 10 
(maximum).

q  

Connect the 

optional headset 

(HS-94, HS-95 or HS-97) 

and 

OPC-2004. (p. 38)

w  

Rotate [VOL] to t

urn the trans-

ceiver power OFF.

e

  Set [ROTARY SELECTOR] to 

Channel 16.

r

 

 

While pushing and holding 
[PTT] and [Upper], rotate [VOL] 
to turn the power ON and 
enter the VOX gain adjustment 
mode.

t

  

Push [Upper] to increase, or 
push [Lower] to decrease  the 
VOX gain while speaking into 
the optional headset.

  • The adjustable range is 1 (minimum) to 10 (maximum).
  • A beep sounds after pushing [Upper] or [Lower].
    If the level is set on 1 or 10, an error beep sounds after pushing.
     Therefore, you can determine the current level setting by the type 

of beep that sounds.

y

  Rotate [VOL] to turn the power OFF, then ON to exit the VOX 

gain adjustment mode.

NOTE:
•  This operation may not be available, depending on the preset-

ting. Ask your dealer for details.

• Set the microphone gain before setting the VOX gain. (p. 18)

[VOL]

[PTT]

[Upper]
[Lower]

[ROTARY SELECTOR]

Содержание IC-F4002

Страница 1: ...INSTRUCTION MANUAL UHF TRANSCEIVER iF4002 VHF TRANSCEIVER iF3002 Limited functions only The photo shows the VHF transceiver...

Страница 2: ...D DEFINITION RDANGER Personal death serious injury or an explo sion may occur RWARNING Personal injury fire hazard or electric shock may occur CAUTION Equipment damage may occur NOTE If disregarded in...

Страница 3: ...iver so that the antenna is very close to or touching exposed parts of the body especially the face or eyes while transmitting The transceiver will perform best if the microphone is 5 to 10 cm away fr...

Страница 4: ...ecome hot when operating it continuously for long periods of time KEEP the transceiver away from heavy rain and never immerse it in the water The transceiver meets IP54 requirements for dust protectio...

Страница 5: ...el selection 13 Call procedure 14 Receiving and transmitting 15 Setting the microphone gain 18 Setting the squelch level 19 Output power level selection 20 Priority A channel selection 20 MDC 1200 sys...

Страница 6: ...ws Battery charger Power adapter Not supplied or the shape is different depending on the version Accessory attachments D Flexible antenna Connect the flexible antenna to the an tenna connector CAUTION...

Страница 7: ...de the belt clip in the direction of the arrow until the belt clip locks in place and makes a click sound Battery pack Belt clip To detach the belt clip q Remove the battery pack from the transceiver...

Страница 8: ...atch until it makes a click sound w q Latch w Battery pack case To remove the battery pack case Unhook the latch e and lift up the battery pack case in the direction of the arrow r e r Be careful The...

Страница 9: ...e and may result in them being damaged NOTE Keep the battery terminals clean It s a good idea to occasionally clean them D Jack cover Attach the jack cover when the optional equipment is not used To a...

Страница 10: ...y u i tLOWER KEY UPPER KEY PTT SWITCH ANTENNA CONNECTOR ROTARY SELECTOR LED INDICATOR VOLUME CONTROL SPEAKER MICROPHONE JACK q ROTARY SELECTOR Rotate to select the pre programmed memory channels w VOL...

Страница 11: ...s re ceived depending on the pre programming r SPEAKER MICROPHONE JACK SP MIC Connect the optional speaker microphone or VOX adapter cable t LOWER KEY Lower y UPPER KEY Upper The desired function can...

Страница 12: ...ceiving a signal Call LED ON Turns ON while receiving a matched 2 5 Tone Call LED Blink Blinks while receiving a matched 2 5 Tone Fast Slow scan Blinks when the Fast Slow scan is activated Low Battery...

Страница 13: ...nd cancel the scanning operation If the scan pauses for any reason except being cancelled by this key it will resume after a specified time period has passed PRIORITY A CHANNEL PRIORITY B CHANNEL Push...

Страница 14: ...return to the mute condition after a specified time period Depending on the presetting pushing and holding this key for 1 sec cancels a scan LOCK Push and hold to electronically lock all programmable...

Страница 15: ...5 kHz using the optional cloning software PMR operation only Ask your dealer for details Push and hold to switch the IF bandwidth to Narrow DTMF AUTODIAL Push to transmit a programmed DTMF code CALL C...

Страница 16: ...owledgement signal or until the power is turned OFF When a matched 5 Tone code signal is received the emergency func tion can be cancelled depending on the presetting PMR operation only SURVEILLANCE P...

Страница 17: ...pe is a Li ion battery pack you must repeat the procedure until 1 beep is heard q Set ROTARY SELECTOR to any channel other than Channel 16 w Rotate VOL to turn OFF the transceiver power e While holdin...

Страница 18: ...ARY SELECTOR Push one of memory channel keys MR CH 1 to MR CH 4 AUTOMATIC SCAN TYPE Selecting a channel is not necessary for this type When turning the power ON the transceiver automatically starts sc...

Страница 19: ...a selective calling system which allows you to call only specific station s and prevent unwanted stations from contacting you q Select a desired TX code channel or 2 5 Tone code according to your Syst...

Страница 20: ...el NOTE When a matched RX code signal is received audio from the microphone is automatically transmitted for a specified time period Depending on the presetting Ask your dealer for details Transmittin...

Страница 21: ...is received The selected channel is a receive only channel Time out timer After continuously transmitting longer than the pre programmed time period the time out timer activates and stops further tran...

Страница 22: ...transceiver When the Stun command is received a beep sounds and the transceiver becomes unusable Receiving a Revive command is necessary to operate the transceiver again in this case When the Kill co...

Страница 23: ...per or Lower If the level is set on 1 or 4 an error beep sounds after push ing Therefore you can determine the current level setting by the type of beep that sounds t Rotate VOL to turn the power OFF...

Страница 24: ...ch level tight squelch or push Lower to decrease the squelch level loose squelch The adjustable range is 0 loose squelch to 9 tight squelch A beep sounds after pushing Upper or Lower If the level is s...

Страница 25: ...g the Priority A channel is selected each time the transceiver power is turned ON MDC 1200 system operation The MDC 1200 signaling system enhances your transceiver s capa bilities It allows PTT ID and...

Страница 26: ...ting the call If your transceiver is programmed for Silent operation you can transmit an Emergency call without the beep sounding and the LED indicator lighting IMPORTANT It is recommended to set an e...

Страница 27: ...time period has passed an emergency call is automatically transmitted once or repeatedly If someone operates the transceiver before the call is transmitted the transceiver exits the emergency mode an...

Страница 28: ...e range will reduce the battery s performance and battery life CAUTION Shorter battery life could occur if the battery is left com pletely discharged or in an excessive temperature environment above 5...

Страница 29: ...ging between 10 C and 40 C rapid charge with BC 191 or between 0 C and 45 C regular charge with BC 192 Use the supplied charger or optional charger BC 191 for rapid charging BC 192 for regular chargin...

Страница 30: ...side the battery may rupture or catch fire R DANGER NEVER use or leave battery packs in areas with tem peratures above 60 C High temperature buildup in the battery such as could occur near fires or st...

Страница 31: ...NEVER put the battery in a microwave oven high pressure container or in an induction heating cooker This could cause a fire overheating or cause the battery to rupture CAUTION Always use the battery w...

Страница 32: ...ty protection circuit in the battery will activate causing the bat tery to stop charging R WARNING DO NOT charge or leave the battery in the battery charger beyond the specified time for charging If t...

Страница 33: ...C 515L CP 23L Charge indicator Lights orange While charging Lights green Charging is completed Poser adapter A different type or no power adapter is sup plied depending on the version About OPC 515L W...

Страница 34: ...16 V Approx 36 hours Approx 21 hours Approx 16 hours About OPC 515L White line Black line CAUTION NEVER connect the OPC 515L to a power source using reverse polarity This will ruin the battery charger...

Страница 35: ...CP 23L Charge indicator Lights orange While charging Lights green Charging is completed Power adapter A different type or no power adapter is sup plied depending on the version About OPC 515L White li...

Страница 36: ...or the OPC 656 dc power cable Transceiver Battery pack Turn OFF the power Status indicator each indicator independently functions OPC 656 DC power cable Power adapter No power adapter is supplied de...

Страница 37: ...hase a BC 197 check the type of battery you are using and then be sure to choose the suitable charger type BC 197 Charger Type Chargeable Battery With AD 120 charger adapters BP 264 Ni MH battery With...

Страница 38: ...33 4 BATTERY CHARGING IMPORTANT Ensure the tabs on the battery pack are correctly aligned with the guide rails inside the charger Guide rail Tabs...

Страница 39: ...inals clean It s a good idea to occasion ally clean them Never incinerate used battery cells since internal battery gas may cause them to rupture Never expose a detached battery case to water If the b...

Страница 40: ...BC 191 desktop charger BC 123S ac adapter For rapid charging of the Ni MH battery pack A power adapter is supplied with the charger depending on the version Charging time Approximately 2 hours for the...

Страница 41: ...ing on the chargeable battery pack D DC POWER CABLES CP 23L cigarette lighter cable Allows charging of the battery pack through a 12 V cigarette lighter socket For BC 191 BC 193 OPC 515L dc power cabl...

Страница 42: ...ok type HS 95 Neck arm type HS 97 Throat microphone OPC 2004 Allows you to connect the HS 94 HS 95 HS 97 to the transceiver After connection the VOX function can be used Approved Icom optional equipme...

Страница 43: ...y required for operation The VOX voice operated transmission function starts transmitting when you speak into the microphone without needing to push the PTT switch then automatically returns to receiv...

Страница 44: ...Set ROTARY SELECTOR to any channel other than Chan nel 16 e While pushing and holding Upper turn the transceiver power ON to switch the VOX function ON or OFF 1 beep sounds when the VOX function is tu...

Страница 45: ...de t Push Upper to increase or push Lower to decrease the VOX gain while speaking into the optional headset The adjustable range is 1 minimum to 10 maximum A beep sounds after pushing Upper or Lower I...

Страница 46: ...uxembourg Malta Netherlands Norway Poland Portugal Romania Slovakia Slovenia Spain Sweden Switzerland Turkey United Kingdom LI LT LU MT NL NO PL PT RO SK SI ES SE CH TR GB Disposal The crossed out whe...

Страница 47: ...MEMO 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20...

Страница 48: ...aka 547 0003 Japan Intended Country of Use AT FI IT PL GB RO BE FR LV PT IS TR CY DE LT SK LI HR CZ GR LU SI NO DK HU MT ES CH EE IE NL SE BG A 6798H 1EU e Printed in Japan 2009 2015 Icom Inc Printed...

Отзывы: