background image

2

PANEL DESCRIPTION

2-6

Programmable function keys (Continued)

The following functions can be assigned to the [Upper], 
[Lower] and [Emer] programmable function keys.

SCAN

Push to start and cancel scanning.

•   When  the  scan  started  with  the  Power  ON  Scan  or  Auto 

Scan function, push to pause the scan. The paused scan 
resumes after the specified time period has passed.

PRIORITY A CHANNEL, PRIORITY B CHANNEL

Push to select the Priority A or Priority B channel.

PRIORITY A CHANNEL (REWRITE),
PRIORITY B CHANNEL (REWRITE)

Push to select the Priority A or Priority B channel.

 

 Hold  down  [Prio  A  (Rewrite)]  or  [Prio  B  (Rewrite)] 

 

for 1 second to assign the operating channel to the 
Priority A or Priority B channel, respectively.

MEMORY CHANNELS 1, 2, 3, 4

Push to directly select memory channel 1, 2, 3 or 4, if 
programmed. 

LONE WORKER

 (p. 3-13)

 Hold down for 1 second to turn ON the Lone Worker 

 

function.

 

•  When  the  Lone  Worker  function  is  turned  ON,  and  no 

operation is performed for the specified time period, the 
Emergency function is automatically turned ON.

Push to turn OFF the Lone Worker function.

 

MONITOR, MONITOR (AUDIBLE)

 Push to turn the CTCSS (DTCS) or 2/5-tone squelch 

 

Mute ON or OFF.

  •  Only  during  LMR  operation,  push  to  open  any  squelch 

functions, or deactivate any mute functions.

  •  Only during PMR operation, push to activate one or two 

of  the following functions on each channel.

    - Hold down to unmute the channel (Audible mode).
    - Push to mute the channel (Inaudible mode).
    -  Push to send a ‘reset code’ after the communication is 

finished.

 

 NOTE:

 The  unmute  condition  may  automatically 

return to the mute condition, after a specified time 
period.

 Depending on the presetting, holding down this key 

 

for 1 second cancels a scan.

LOCK

Hold down to electronically lock all programmable keys 
except [Moni(Audi)], [Call] (including Call A and Call B), 
[Emergency],  [Surveillance] and [Lone Worker].

HIGH/LOW

 (p. 3-12)

Select  the  transmit  output  power  level  temporarily  or 
permanently, depending on the presetting.

TALK AROUND

 Hold down for 1 second to turn ON the Talk Around 

 

function.

  •  The Talk Around function equalizes the transmit frequen

-

cy to the receive frequency for transceiver-to-transceiver 
communication.

Push to turn OFF the Talk Around function.

 

DTMF AUTODIAL

Push to transmit a programmed DTMF code.

RE-DIAL

Push to transmit the last-transmitted DTMF code.

NOTE:

 TX memories are cleared after turning OFF 

the transceiver.

WIDE/NARROW

Push  to  select  the  IF  bandwidth  between Wide,  Mid* 
or Narrow.

* Depending on the presetting, the Mid channel width may not 

be selectable.

CALL, CALL A, CALL B

Push to transmit a 2/5-tone code.

•  Tone  call  transmission  may  be  necessary  before  you  call 

another station, depending on your signalling system.

•  [Call A] and/or [Call B] keys may be selectable when your 

system employs selective ‘Individual/Group’ calls.

EMERGENCY

Hold  down  for  specified  time  period  to  transmit  an 
emergency call.

•  The  emergency  call  transmits  with  beeps,  and  the  status 

indicator lights red.

•  The transceiver can transmit an emergency call without the 

beep sounding and the status indicator lighting.

•  If you want to cancel the emergency call, hold down the key 

again before transmitting the call.

•  The emergency call is transmitted one time only, or repeat

-

edly until receiving an acknowledgement signal, or until the 
power is turned OFF.

   When a matched 5-tone code signal is received, the emer-

gency function can be cancelled, depending on the preset-
ting. (PMR operation only)

Содержание IC-F3200DEX

Страница 1: ...STRUCTIONS iF3200DEX series 5 SPEAKER MICROPHONE 4 dPMR OPERATION 3 BASIC OPERATION 2 PANEL DESCRIPTION 1 ACCESSORIES INTRODUCTION VHF DIGITAL ANALOG TRANSCEIVERS iF4200DEX series UHF DIGITAL ANALOG T...

Страница 2: ...EX vhf digital analog transceivers and IC F4201DEX IC F4202DEX or IC F4203DEX uhf digital analog transceivers NOTE To use in explosive atmospheres read the leaflet SAFETY MANUAL comes with the transce...

Страница 3: ...1 1 Section 1 ACCESSORIES Supplied accessories 1 2 Accessory attachments 1 3 Flexible antenna D D 1 3 Battery pack D D 1 3 Belt clip D D 1 4 Connector cover D D 1 4...

Страница 4: ...lowing accessories are supplied Battery pack Belt clip Connector cover with screws Battery charger Power adapter Not supplied or the shape is different depending on the transceiver s version Flexible...

Страница 5: ...r in the direction of the arrow q then lock it with the battery release button Slide the battery pack until the battery release button makes a click sound To remove the battery pack Push the battery r...

Страница 6: ...of the arrow w Accessory attachments Continued Connector cover D D To attach the connector cover Place the connector cover over the multi connector q q q Tighten the screw w w w To detach the connecto...

Страница 7: ...2 1 Section 2 PANEL DESCRIPTION Front top and side panels 2 2 Status indicator 2 3 Programmable function keys 2 5...

Страница 8: ...s received depending on the presetting rMULTI CONNECTOR Connect optional accessory CAUTION Attach the connector cover when the optional acces sory is not used Otherwise the terminals of the multi conn...

Страница 9: ...our call was successful Call error Blinks slowly when your call failed or was refused Audible Blinks slowly after a return signal is received when in the Audible mode Mute is released Received signal...

Страница 10: ...in the TX inhibit mode such as when the TOT or Lockout function is activated Emergency Blinks when an Emergency call was received Emergency Locator Ringer Siren Blinks while the Emergency locator Ring...

Страница 11: ...2 PANEL DESCRIPTION 2 5 Programmable function keys The programmable key functions can be assigned to the Upper Lower and Emer programmable func tion keys LOWER KEY UPPER KEY EMERGENCY KEY...

Страница 12: ...pending on the presetting holding down this key for 1 second cancels a scan LOCK Hold down to electronically lock all programmable keys except Moni Audi Call including Call A and Call B Emergency Surv...

Страница 13: ...n sound This function can be used for situations other than an emergency alert such as a security alarm for exam ple The transceiver emits the siren sound until the power is turned OFF SCRAMBLER Hold...

Страница 14: ...and transmitting 3 5 Transmitting notes D D 3 5 DTMF transmission D D 3 6 Receiving a Stun Kill and Revive command D D 3 6 Setting the Beep function 3 7 Setting the beep level 3 8 Setting the ringer...

Страница 15: ...g the battery pack for the first time or after not using it for a long time you must fully charge the pack for optimum battery life and operation See BASIC INSTRUCTIONS that are provided with the tran...

Страница 16: ...ps when a signal is detected Voting Operation D D The transceiver automatically starts scanning when a zone specified for the voting operation is selected The voting scan detects the signal of the rep...

Страница 17: ...stem which allows you to call only spe cific station s and prevents unwanted stations from contacting you Select a desired TX code channel or 2 5 tone code q q according to your System Operator s inst...

Страница 18: ...your signal 1 Pause briefly after pushing PTT 2 Hold the microphone 5 to 10 cm 2 to 4 inches from your mouth then speak at a normal voice level Transmitting notes D D Transmit inhibit function The tr...

Страница 19: ...that will stun kill or revive your transceiver When the Stun command is received a beep sounds and the transceiver becomes unusable Receiving a Revive command is necessary to operate the trans ceiver...

Страница 20: ...ELECTOR to any channel other w w than Channel 16 While holding down Lower rotate VOL to turn ON e e the power to enter the Beep level adjustment mode Push Lower to turn the Beep function ON or OFF r r...

Страница 21: ...s every time you push Upper Therefore you can determine the current level setting by the in creasing loudness of the beep that sounds To determine if you have selected a linked level set VOL to minimu...

Страница 22: ...ht A beep sounds after pushing Upper or Lower There fore you can determine the current level setting by the increasing loudness of the beep that sounds To determine if you have selected a linked level...

Страница 23: ...one gain adjust ment mode Push Upper or to increase or push Lower to de r r crease the microphone gain The adjustable range is 1 minimum to 4 maximum A beep sounds after pushing Upper or Lower An erro...

Страница 24: ...el adjustment mode Push Upper to increase the squelch level tight r r squelch or push Lower to decrease the squelch level loose squelch The adjustable range is 0 loose squelch to 9 tight squelch A bee...

Страница 25: ...ding on the presetting When the battery voltage drops to a low power level and the status indicator indicates Low Battery 2 the output power automatically switches to Low 1 p 2 3 Push High Low to sele...

Страница 26: ...ied time period has passed an emer gency call is automatically transmitted once or repeat edly If someone operates the transceiver before the call is transmitted the transceiver exits the emergency mo...

Страница 27: ...eceiving a Stun Kill or Revive D D 4 3 Receiving a Status Polling call D D 4 3 Receiving an Ambience Listening call D D 4 3 Receiving an Emergency call D D 4 3 Talk back function D D 4 3 Transmitting...

Страница 28: ...iding digital Private Mobile Radio dPMR operation meets the 6 25 kHz bandwidth re quirements for narrow band operation This increases the efficiency of channel allocation and use of the spec trum NOTE...

Страница 29: ...ELECTOR is changed the trans ceiver will stay on the same channel the Stun command received on When a Kill command is received The status indicator alternately blinks red and green The transceiver can...

Страница 30: ...is held down for the specified time period the emergency signal digital command is trans mitted once or repeatedly on the specified emergency channel When no emergency channel is specified the signal...

Страница 31: ...essage can automatically be transmitted The status message is transmitted when the transceiv er is turned ON or OFF Select a status message to be transmitted in Power ON Status or Power OFF Status ite...

Страница 32: ...The voice scrambler function provides private commu nication between stations while operating in the digital mode Hold down Scrambler for 1 second to turn ON the q q Scrambler function Push Scrambler...

Страница 33: ...5 1 Section 5 SPEAKER MICROPHONE Optional HM 203EX 5 2 Description D D 5 2 To attach D D 5 2...

Страница 34: ...power when connecting or dis connecting the mi crophone To attach D D BE SURE to turn OFF the power before attaching Attach the connector of the speaker microphone into the multi connector on the tran...

Страница 35: ...1 1 32 Kamiminami Hirano ku Osaka 547 0003 Japan A 7166 4EX 2014 Icom Inc...

Отзывы: