5 - 13
5-12 S-METER ADJUSTMENT
(continued)
1) Select an adjustment item using
[2]
/
[8]
.
2) Set the SSG as specifi ed (frequency, deviation and output level).
3) Push the
[BAND]
to adjust (automatic) and store the adjustment value.
ADJUSTMENT
ADJUSTMENT
ITEM
OPERATION
VALUE
S-METER S3 LEVEL
(WFM)
[1.01 MHz*]
[S3]
1
• Set the SSG as;
Frequency
: (Displayed on the function display)
Deviation
: 52.5 kHz
Level
: 5 dBµ (–102 dBm)
†
Push
[BAND]
.
(Automatic
adjustment)
[15.1 MHz*]
2
• Set the SSG as;
Frequency
: (Displayed on the function display)
Level
: 3 dBµ (–104 dBm)
†
[40.1 MHz*]
3
• Set the SSG as;
Frequency
: (Displayed on the function display)
Level
: 5 dBµ (–102 dBm)
†
[60.1 MHz*]
4
• Set the SSG as;
Frequency
: (Displayed on the function display)
Level
: 5 dBµ (–102 dBm)
†
[220.1 MHz*]
5
• Set the SSG as;
Frequency
: (Displayed on the function display)
Level
: 5 dBµ (–102 dBm)
†
[305.2 MHz*]
6
• Set the SSG as;
Frequency
: (Displayed on the function display)
Level
: 5 dBµ (–102 dBm)
†
[435.1 MHz*]
7
• Set the SSG as;
Frequency
: (Displayed on the function display)
Level
: 5 dBµ (–102 dBm)
†
[535.1 MHz*]
8
• Set the SSG as;
Frequency
: (Displayed on the function display)
Level
: 5 dBµ (–102 dBm)
†
[800.1 MHz*]
9
• Set the SSG as;
Frequency
: (Displayed on the function display)
Level
: 11 dBµ (–96 dBm)
†
†
; This output level of a standard signal generator (SSG) is indicated as SSG’s open circuit.
*; This frequency may differ from the actual frequency displayed on the function display.