5-8
D
D
Scope set mode (continued)
5
FUNCTIONS FOR RECEIVE
Set the scope edge frequencies for fix mode scope
when 30 to 45 MHz band is selected.
• Set the frequencies within 30.000 to 45.000 MHz
range in 1 kHz steps.
Up to 500 kHz band width can be specified, so
either edge frequency will be set to the differ-
ence between higher and lower frequencies
become 5 to 500 kHz automatically while setting
another edge frequency.
Set the scope edge frequencies for fix mode scope
when 45 to 60 MHz band is selected.
• Set the frequencies within 45.000 to 60.000 MHz
range in 1 kHz steps.
Up to 500 kHz band width can be specified, so
either edge frequency will be set to the differ-
ence between higher and lower frequencies
become 5 to 500 kHz automatically while setting
another edge frequency.
Set the scope edge frequencies for fix mode scope
when 26 to 30 MHz band is selected.
• Set the frequencies within 26.000 to 30.000 MHz
range in 1 kHz steps.
Up to 500 kHz band width can be specified, so
either edge frequency will be set to the differ-
ence between higher and lower frequencies
become 5 to 500 kHz automatically while setting
another edge frequency.