9
CONTROL COMMAND
42
• Command table
Command
Sub command
Description
00
—
Send frequency data
01
—
Send mode data
02
—
Read Upper/Lower frequencies
03
—
Read frequencies
04
—
Read operating mode
05
—
Set operating frequency
06
—
Set mode
08
—
Set memory
—
Set memory channel
0E
00
Scan stop
01
Memory scan start
11
—
ATT
01
AF gain
14
02
RF gain
03
Squelch level
15
01
Read squelch Open/Close
02
Read S-meter level
02
PREAMP
16
22
Noise blanker
44
Microphone compressor
19
00
Read ID
■
Data cloning between transceivers
• Data cloning
The IC-78’s data (programmed frequencies, channel comment, both quick and initial set mode conditions, etc.) can
be copied to the other IC-78. This function is useful when exactly the same setting of the IC-78s is required.
• Cloning operation
q
Turn power OFF.
w
Connects a mini-plug cable between two IC-78’s
(master and sub) [REMOTE] jack.
e
While pushing [TXF] and [FC], turn the master IC-
78 power ON.
r
While pushing [SET] and [FC], turn the sub IC-78
power ON.
t
Push [TONE] of the master IC-78 to start cloning.
• After cloning complete;
y
Turn power OFF
Master transceiver
indicates “M”.
[REMOTE] jack
Mini-plug cable
to [REMOTE]
to other IC-78’s
[REMOTE]
Master transceiver
indication
Daughter transceiver
indication
Daughter transceiver
indication