Cmd. Sub cmd.
Data
Description
00
see p. 10
Send frequency data (transceive)
01
see p. 10
Send mode data (transceive)
02
see p. 10
Read band edge frequencies
03
see p. 10
Read operating frequency
04
see p. 10
Read operating mode
05
see p. 10
Set operating frequency
06
see p. 10
Set operating mode
07
Select the VFO mode
B0
Exchange main and sub bands
B1
Equalize main and sub bands
C0
Turn OFF Dualwatch
C1
Turn ON Dualwatch
C2*
00 or 01
Send/read the dualwatch setting
(00=OFF, 01=ON)
D0
Select the main band
D1
Select the sub band
D2*
00
Send/read main band selection
01
Send/read sub band selection
08
Select the Memory mode
0001 to 0099 Select the Memory channel
(0001=M-CH01, 0099=M-CH99)
0100
Select program scan edge channel P1
0101
Select program scan edge channel P2
09
Memory write
0A
Memory copy to VFO
0B
Memory clear
0E
00
Cancel the scan
01
Start a Programmed/memory scan
02
Start a Programmed scan
03
Start a
∂
F scan
12
Start a Fine programmed scan
13
Start a Fine
∂
F scan
22
Start a Memory scan
23
Start a Select memory scan
Ax
(x=1 to 7)
Select
∂
F scan span
( x=1 (±5 kHz), x=2 (±10 kHz),
x=3 (±20 kHz), x=4 (±50 kHz),
x=5 (±100 kHz), x=6 (±500 kHz),
x=7 (±1 MHz))
B0
Clear the Select channel setting
B1
Set as select channel
( The previously set number by CI-V is set
after turning power ON, or “1” is selected if
no selection is performed.)
01 to 03
Set the channel as a Select channel
(01=SEL1, 02=SEL2, 03=SEL3)
B2
00 to 03
Set the Select memory scan channel
(00=ALL, 01=SEL1, 02=SEL2, 03=SEL3)
D0
Set Scan resume OFF
D3
Set Scan resume ON
0F
00
Read Split OFF setting
01
Read Split ON setting
00
Turn OFF the Split function
01
Turn ON the Split function
10*
00 to 08
Send/read the tuning step
(
00=OFF (10 Hz or 1 Hz),
01=100 Hz, 02=1 kHz, 03=5 kHz,
04=9 kHz, 05=10 kHz,
06=12.5 kHz, 07=20 kHz,
08=25 kHz)
11*
00
Send/read attenuator OFF setting
03
Send/read 3 dB attenuator setting
06
Send/read 6 dB attenuator setting
09
Send/read 9 dB attenuator setting
12
Send/read 12 dB attenuator setting
15
Send/read 15 dB attenuator setting
18
Send/read 18 dB attenuator setting
21
Send/read 21 dB attenuator setting
24
Send/read 24 dB attenuator setting
Cmd. Sub cmd.
Data
Description
27
Send/read 27 dB attenuator setting
30
Send/read 30 dB attenuator setting
33
Send/read 33 dB attenuator setting
36
Send/read 36 dB attenuator setting
39
Send/read 39 dB attenuator setting
42
Send/read 42 dB attenuator setting
45
Send/read 45 dB attenuator setting
12* 00*
1
00 or 01
Select/read ANT1 selection
(00=RX ANT OFF, 01=RX ANT ON)
01*
1
00 or 01
Select/read ANT2 selection
(00=RX ANT OFF, 01=RX ANT ON)
13
00
Speech all data with voice synthesizer
(S meter level, frequency and mode)
01
Speech the operating frequency and S meter
level by voice synthesizer
02
Speech the operating mode by voice synthesizer
L
The mode is announced after the ongoing
speech.
14* 01
0000 ~ 0255 Send/read the AF level
(0000=min. to 0255=max.)
02
0000 ~ 0255 Send/read the RF gain level
(0000=min. to 0255=max.)
03
0000 ~ 0255 Send/read the squelch level
(0000=min. to 0255=max.)
05
0000 ~ 0255 Send/read the APF level (10 Hz steps)
( 0000=Pitch–550 Hz, 0128=Pitch,
0255=Pitch+550 Hz)
06
0000 ~ 0255 Send/read the NR level
(0000=0%, 0255=100%)
07
0000 ~ 0255 Send/read inner [TWIN PBT] position
( 0000=max. CCW, 0128=center, 0255=max.
CW)
08
0000 ~ 0255 Send/read outer [TWIN PBT] position
( 0000=max. Counter Clockwise, 0128=center,
0255=max. Clockwise)
09
0000 ~ 0255 Send/read CW pitch (5 Hz steps)
( 0000=300 Hz, 0128=600 Hz, 0255=900 Hz)
0A
0000 ~ 0255 Send/read RF power
( 0000=min. to 0255=max.)
0B
0000 ~ 0255 Send/read MIC gain
( 0000=min. to 0255=max.)
0C
0000 ~ 0255 Send/read keying speed
(0000=6 wpm to 0255=48 wpm)
0D
0000 ~ 0255
Send/read Nothc filter setting
( 0000=max. Counter Clockwise, 0128=center,
0255=max. Clockwise)
0E
0000 ~ 0255 Send/read the COMP level
(0000=0 to 0255=10)
0F
0000 ~ 0255 Send/read the Break-IN Delay setting
(0000=2.0 d to 0255=13.0 d)
12
0000 ~ 0255 Send/read NB level
(0000=0% to 0255=100%)
13
0000 ~ 0255 Send/read the DIGI-SEL shift amount
( 0000=min. to 0255=max.)
14
0000 ~ 0255 Send/read DRIVE gain
(0000=0% to 0255=100%)
15
0000 ~ 0255 Send/read Monitor audio [MONI] level
(0000=0% to 0255=100%)
16
0000 ~ 0255 Send/read the VOX gain
(0000=0% to 0255=100%)
17
0000 ~ 0255 Send/read the Anti VOX gain
(0000=0% to 0255=100%)
19
0000 ~ 0255 Send/read LCD backlight brightness
(0000=0% to 0255=100%)
15
01
00 or 01
Read noise or S-meter squelch status
(00=Close, 01=Open)
02
0000 to 0255 Read S-meter level
(0000=S0, 0120=S9, 0241=S9+60 dB)
05
00 or 01
Read various squelch (tone squelch, and so
on) status
(00=Close, 01=Open)
D
Command table
NOTE:
Operation to the some control dials overrides CI-V commands. If a control dial (such as the AF Volume dial that
has a mark on it) is rotated after sending a CI-V command, the command will be overwritten by the operation.
11*
Remote control
3