8-3
8
SCAN OPERATION
■
Scan edges programming
Memory channels P1 and P2 are the Program Scan
Edge channels. They are used to program the upper
and lower frequency edges for the programmed scan.
(p. 8-4)
Factory default frequency and operating modes are
programmed into the Scan Edge channels.
If both upper and lower band edges are programmed
with the same frequency, a programmed scan cannot
start.
[EXAMPLE]: Programming 14.00000 MHz into P1
and 14.35000 MHz into P2.
Push
q
V/M
➔
to select the VFO mode.
Rotate
w
[M-CH] to select scan edge P1.
• If the RIT control indicator lights orange, push
M-CH/RIT
SET
.
(p. 7-2)
Set 14.00000 MHz as the lower frequency.
e
Hold down
r
MW
for 1 second to write 14.00000 MHz
into scan edge P1.
• 3 beeps sound when memory writing is completed.
Rotate
t
[M-CH] to select scan edge P2.
Set 14.35000 MHz as the upper frequency.
y
Hold down
u
MW
for 1 second to write 14.35000 MHz
into scan edge P2.
• 3 beeps sound when memory writing is completed.
When a programmed scan is started, it will
i
search for signals between 14.00000 MHz and
14.35000 MHz. (p. 8-4)
Rotate
[M-CH]
[M-CH]
VFO mode
Rotate
[M-CH]
Hold down
MW
to write the
lower frequency into P1.
The lower frequency is set.
The upper frequency is set.
Select
Select
Hold down
MW
to write the
upper frequency into P2.
Previous view