3 - 1
3-1 RECEIVER CIRCUITS
3-1-1 RF CIRCUIT (PA AND MAIN UNITS)
HF/50 MHz RF filters pass only the desired band signals
and suppress any undesired band signals. The HF/50 MHz
RF circuit has 7 low-pass filters and 6 high-pass filters for
specified band use.
HF/50 MHz RF signals from the [ANT] connector, pass
through one of 7 low-pass filters as below, the transmit/
receive switching relay (PA unit; RL250) and low-pass filter
(PA unit; L300, L301, C304–C308), and are then applied to
the MAIN unit via J300 (PA unit).
The signals from the PA unit are applied to or bypass the 20
dB attenuator (MAIN unit; R2, R3). The signals pass through
the high-pass filter (MAIN unit; L301–L303, C301–C303) to
suppress strong signals above 1.6 MHz and are then
applied to the HPF section.
(1) 0.03–2 MHz and 30–40 MHz
The signals pass through a low-pass filter (L304, L305,
C306–C310), and then applied to the preamplifier circuit on
the MAIN unit.
(2) 2–30 MHz
The signals from the low-pass filter (L304, L305,
C306–C310) are applied to one of 5 high-pass filters as at
right above and are then applied to the preamplifier circuit
on the MAIN unit.
(3) 40–60 MHz
The signals pass through the high-pass filter (L502–L504,
C501–C505) and the low-pass filter (L501, L506–L508
C506–C513), and are then applied to the preamplifier circuit
on the MAIN unit.
3-1-2 PREAMPLIFIER CIRCUIT (MAIN UNIT)
The preamplifier circuit in the IC-703 has approx. 15dB gain
over a wide-band frequency range.
When the preamplifier is turned ON, the signals from the RF
circuit are applied to the preamplifier (Q651) via D622 or
D632. Amplified or bypassed (passes through the D601 and
D602 when bypassed) signals are applied to the 1st mixer
circuit (D701).
3-1-3 1ST MIXER CIRCUIT (MAIN UNIT)
The 1st mixer circuit mixes the receive signals with the 1st
LO signal to convert the receive signal frequencies to a
64.455 MHz 1st IF signal.
The signals from the preamplifier circuit, or signals which
bypass the preamplifier, are passed through a low-pass fil-
ter (L681–L683, C681–C687) and then applied to the 1st
mixer (D701).
The 1st LO signal (one of the 64.485–124.455 MHz) is
amplified at Q751, filtered by a low-pass filter (L753,
C756–C759), passed through the attenuator (R771–R773),
and then applied to the 1st mixer.
3-1-4 1ST IF CIRCUIT (MAIN UNIT)
The 1st IF circuit filters and amplifies the 1st IF signals. The
1st IF signals are applied to a Crystal Filter (FI851) to sup-
press out-of-band signals.
The 64.445 MHz 1st IF signals pass through the crystal fil-
ter (FI851). Then the filtered signals are applied to the IF
amplifier (Q881).
The AGC voltage is supplied to the Q881’s gate to obtain
stable signal for AGC operation.
• Used RF high-pass filter (MAIN unit)
• Used RF low-pass filter (MAIN unit)
SECTION 3
CIRCUIT DESCRIPTION
Frequency
(MHz)
0.03–2 MHz
2–4 MHz
4–8 MHz
8–15 MHz
Frequency
(MHz)
15–22 MHz
22–30 MHz
30–60 MHz
Control
signal
F5
F6
F7
Control
signal
F1
F2
F3
F4
Entrance
coil
RL401
RL421
RL441
RL461
Entrance
coil
RL481
RL501
RL521
Frequency
(MHz)
0.03–2 MHz
2–4 MHz
4–8 MHz
8–15 MHz
Frequency
(MHz)
15–22 MHz
22–30 MHz
30–40 MHz
40–60 MHz
Control
signal
B5H
B6H
BTHH
B7RH
Control
signal
BTHH
B2H
B3H
B4H
Entrance
coil
D541
D551
D561
D571
Entrance
coil
D581
D591
D541
D501
1st LO:
69.0415 MHz—
530.0115 MHz
LPFs
HPFs
1st mixer
D701
2nd LO:
60.0 MHz
2nd
mixer
D901
to AM demod.
circuit (D2001)
to FM demod.
circuit (IC2101)
[ANT]
0.03—60 MHz
Crystal
filter
FI851
64.455 MHz
Ceramic
filter
NB
Det.
FI1501
to BFO circuit
(IC1901)
9.0115MHz
PA UNIT
MAIN UNIT
SSB, CW
filter
FI1301
AM, FM-N
filter
FI1341
FM mode
Optional
filter
amp.
Pre-amp.
Q651
• 2ND IF AND DEMODULATOR CIRCUIT