9
MENU SCREEN
9-18
Pause Timer
(Default: 10sec)
Scan >
Pause Timer
Select the scan Pause time. When receiving a signal,
the scan pauses for the scan Pause Timer time.
•
2sec ~ 20sec : When a signal is received, the scan
pauses for 2 ~ 20 seconds (set in 2
second steps).
•
HOLD
: The scan pauses on a received
signal until the signal disappears.
Resume Timer
(Default: 2sec)
Scan >
Resume Timer
Select the scan Resume Timer time.
When a received signal disappears, the scan resumes
according to the scan Resume Timer setting.
• 0sec:
The scan resumes immediately after
the signal disappears.
• 1sec ~ 5sec: The scan resumes 1 ~ 5 seconds after
the signal disappears.
• HOLD:
The scan remains paused for the
Pause Timer setting, even if the signal
disappears.
NOTE:
Rotate [DIAL] to resume the scan. The
Resume Timer must be set shorter than the Pause
Timer, otherwise this timer does not work properly.
Temporary Skip Timer
(Default: 5min)
Scan >
Temporary Skip Timer
Set the Temporary Skip Timer to 5, 10 or 15 minutes.
When the time is set, the unwanted frequencies are
skipped for this set period during a scan.
This timer is activated for the VFO scan, Memory scan
and DR scan.
Program Skip
(Default: ON)
Scan >
Program Skip
Turn the Program Skip Scan function ON or OFF for a
VFO mode scan.
This function enables the transceiver to skip the
unwanted frequencies or channels that inconveniently
stop scanning.
Set the unwanted frequencies or channels to “PSKIP”
in the Memory Channel screen.
• OFF: The transceiver scans all frequencies.
• ON: The transceiver does not scan frequencies set
as “PSKIP” frequencies.
Bank Link
(Default: A:
✔
~ Z:
✔
)
Scan >
Bank Link
Select banks to be scanned during a Bank Link Scan.
The Bank Link function scans all channels in the
selected banks.
Select a bank, A ~ Z, then push [
ï
] to turn the Link
function ON or OFF.
•Displays “
✔
” when the function is set to ON.
Program Scan Edge
Scan >
Program Scan Edge
You can delete, copy or edit the lower and higher
frequencies for programmed scans.
The transceiver has a total of up to 25 frequency
ranges (00 ~ 24), and you can set scan name, tuning
step, and the receive mode for each scan edge.
The default setting is differ, depending on the
transceiver version.
See page 2-9 for Entering scan edges.
Scan items