5-8
ADJUSTMENT ITEM
TRANSCEIVER'S DISPLAY
CONDITION
VALUE
S-METER
Air band S1
78
• Connect the test equipment to the antenna
connector and set as shown below:
Frequency: As
displayed
Modulation: None
Output level: S1
–
6 dB
μ
†
(
–
113 dBm)
S3 0 dB
μ
†
(
–
107 dBm)
Full +10 dB
μ
†
(
–
97 dBm)
• Receive
Push [DIAL]
for automatic
adjustment.
Air band S3
79
Air band Full
80
VHF S1
81
VHF S3
82
VHF Full
83
UHF Low S1
84
UHF Low S3
85
UHF Low Full
86
UHF Center S1
87
UHF Center S3
88
UHF Center Full
89
UHF High S1
90
UHF High S3
91
UHF High Full
92
4-3 RECEIVE ADJUSTMENT (continued)
Select an adjustment item using [MONI]/[QUICK], and then set the adjustment value as specified using [DIAL].
NOTE: The displayed adjustment frequency is only an example, and the frequency will differ depending on the transceiver version.
†
: The output level of the standard signal generator (SSG) is indicated as the SSG’s open circuit.