5-7
ADJUSTMENT ITEM
TRANSCEIVER'S DISPLAY
CONDITION
VALUE
RECEIVE
SENSITIVITY
66
• Connect the test equipment to the antenna
connector and set as shown below:
Frequency: As
displayed
Modulation: None
Output level: 0 dB
μ
†
(
–
107 dBm)
• Receive
Push [DIAL]
for automatic
adjustment.
67
68
69
70
71
72
73
74
RECEIVE
SENSITIVITY
(continued)
75
• Connect an SSG to the antenna connector
and set as shown below:
Frequency: As
displayed
Modulation: Non
Output level: 0 dB
μ
• Receive
Push [DIAL]
for automatic
adjustment.
76
77
4-3 RECEIVE
ADJUSTMENTS
Select an adjustment item using [MONI]/[QUICK], and then set the adjustment value as specified using [DIAL].
NOTE: The displayed adjustment frequency is only an example, and the frequency will differ depending on the transceiver version.
†
: The output level of the standard signal generator (SSG) is indicated as the SSG’s open circuit.