Electrical rating:
. •.24.VAC.(18-30.VAC)
.
•.1.amp.maximum.per.terminal
.
•.4.amp.maximum.total.load
Temperature control range:
45°F.to.90°F.(7°C.to.32°C)...
Accuracy:
.±.1°F.(±.0.5°C)
System configurations:
.2-stage.heat,.2-stage.cool,.heat.pump,.gas,.oil,.electric
Terminations:
.R,.C,.W1/O/B,.Y1,.W2,.Y2,.G,.S1,.S2
Specifications
WARNING!
:
Always turn off power at the main power supply before installing, cleaning, or removing
thermostat.
•.This.thermostat.is.for.24.VAC.applications.only;.do.not.use.on.voltages.over.30.VAC
•.Do.not.short.across.terminals.of.gas.valve.or.system.control.to.test.operation;.this.will.damage.your.
thermostat.and.void.your.warranty
•.All.wiring.must.conform.to.local.and.national.electrical.and.building.codes
•.Do.not.use.air.conditioning.when.the.outdoor.temperature.is.below.50.degrees;.this.can.damage.your.
A/C.system.and.cause.personal.injuries
•.Use.this.thermostat.only.as.described.in.this.manual
Important Safety Information
Package includes:
. SimpleComfort
®
.3801.programmable.thermostat.on.base,.labeled.thermostat.cover,.
wiring.labels,.screws.and.wall.anchors,.Owner’s.Manual,.Installation,.Operation.and.
Application.Guide.
Tools required for installation:
.Drill.with.3/16”.bit,.hammer,.screwdriver.
Package Contents/Tools Required